HORNER X5 Prime PLC HMI controller with 4,3″ colour touchscreen, analog / digital inputs and outputs

HORNER X5 Prime PLC HMI controller with 4,3″ colour touchscreen, analog / digital inputs and outputs

Software for free FOXON PLUS

Horner Automation

HORNER X5 PRIME connects PLC, 4,3″ color touch screen, 4 digital inputs, 4 transistor outputs and 4 analog inputs. Cscape for PLC program and screens is free. FOXON will help with selection, first project and training.

Arrange a trial loan


More

Code: HE-XP5

931 EUR excl. VAT (1 126,51 EUR Incl. VAT)
Delivery in 1-2 weeks
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote

Horner Automation

HORNER X5 PRIME connects PLC, 4,3″ color touch screen, 4 digital inputs, 4 transistor outputs and 4 analog inputs. Cscape for PLC program and screens is free. FOXON will help with selection, first project and training.

Arrange a trial loan


More

Code: HE-XP5

HORNER X5 PRIME · PLC + HMI + I/O

PLC, control and I/O in one panel.

HORNER X5 PRIME connects PLC, 4,3″ color touch screen and 12 built-in inputs and outputs. From one place, you collect signals, control a small machine or fixture and change technology settings. A fixed combination of 4 digital inputs, 4 transistor outputs and 4 analog inputs makes it easy to choose for smaller jobs.

Standard Cscape for both PLC program and HMI screens is free with each panel. You do not buy a programming license. Optional communication and web features have their own license and firmware terms.

HORNER X5 PRIME - device photo

Verify X5 PRIME on your own task.
Free loan of selected products for 14 days is arranged individually according to availability. We will confirm the specific model, date and conditions in advance. FOXON will help with the selection and the first project.

4,3″ color touch480 × 272 px for operation and overview of values
12 built-in I/O4 DI + 4 DO + 4 analog inputs
2 MB program memoryCscape for both logic and screens

Introducing X5 PRIME

The Horner short product video introduces the X5 PRIME and its basic equipment. English.

Watch the introduction on YouTube

Applications in small machines and systems

Pump switching according to time or event

Starting at a specified time, running for a set time or reacting to a level and other input signal. The operator sets the values ​​and sees the pump status on the display.

Controlling a small machine or fixture

Starting the work cycle, continuity of individual steps and counting of pieces. The operator changes the length of the step or the number of repetitions on the panel.

Measurement and simple regulation

Display of pressure, temperature or other quantity and reaction to the set limit. The sensor type and signal range must match the selected panel inputs.

Local equipment monitoring

Input states, error messages and common settings on one display. You can prepare the range of screens and controls according to the specific device.

You create a function for your technology in Cscape. Select the necessary sensors and control elements according to the device.

Trial loan and training

Free loan by agreement

Free loan of selected products for 14 days is arranged individually according to availability. We will confirm the specific model, date and conditions in advance.

Training in Liberec

We train individuals and groups in our training room in Liberec. We will agree on the scope and date according to the experience of the participants and their tasks.

The original Horner Automation Europe video instructions are used for self-study. Translated titles and annotations explain their content, videos remain in English. Horner Europe video tutorials on YouTube

Selection of variant X5 PRIME

On this page you order the HE-XP5 with a fixed combination of 4 digital inputs, 4 transistor outputs and 4 analog inputs. For a different number or type of signals, we will select a suitable extension or a different model.

HE-XP5

4 digital inputs, 4 transistor outputs and 4 analog inputs 0-10 V, 0-20 mA or 4-20 mA.

For smaller tasks with a color touch screen. It has no built-in relay or analog outputs.

We will advise you on the selection of a suitable design and accessories according to the project.

Signal types and wiring limitations

Built-in analog inputs support 0-10 V, 0-20 mA and 4-20 mA; direct measurement of Pt100 and thermocouples is not their function. Set the current or voltage mode according to the connection and configuration. High-speed counters use the same four digital inputs. Transistor outputs are limited to 0,5 A per channel and 2 A in total; control the power load via the corresponding power element. X5 PRIME does not have built-in analog or relay outputs.

Technical parameters HORNER X5 PRIME

Display4,3″ color touch, 480 × 272 px
Program memory2 MB
Built-in I/O4 digital inputs + 4 transistor outputs + 4 analog inputs
Analog signals0-10 V, 0-20 mA, 4-20 mA; 12 bits
ConnectionEthernet, RS232, RS485, CAN, USB Mini-B, USB-A and microSD
Power supply10-30 V DC; commonly 24 V DC
Operating temperature-10 to +60 °C

You can find detailed information in the tab Features.

Connection and operation

X5 PRIME has Ethernet 10/100 Mb/s, RS232 and RS485 in common connector MJ1/2 and CAN for corresponding remote I/O. For data exchange, you can use, for example, Modbus TCP or Modbus RTU, depending on the configuration. USB-A and microSD are used for working with data, USB Mini-B for PC connection.

You can create both the PLC program and the standard HMI screens in the free Cscape. WebMI, MQTT, J1939 and other optional features are judged by their license and required firmware version. We will verify the required communication and its price in the offer.

HORNER X5 PRIME - photo of the device from the front
Photograph of the device from the front

Equipment and cost of first launch

Panel HORNER X5 PRIMEThe current price of the panel above
Standard Cscape0 CZK - program PLC and screens HMI
Power supply and connection24 V DC power supply and programming link USB Mini-B or Ethernet; separate items depending on the setup.
Sensors and controlsAccording to the signals and loads of your job
Training, design and assemblyPricing according to the agreed scope

The price of the panel is not the price of the entire automation. In the offer, we will discuss the necessary equipment and the possible work of technicians. We select the source, cables and other accessories according to the assembly.

Contents of the standard package

HE-XP5 panel and mounting accessories. We will confirm the exact range of supplied connectors before ordering. Select the source, programming cable, memory medium and sensors separately according to the assembly.

First project in Cscape

Download Cscape from Horner. You need a manufacturer account to download Cscape. The video shows the PC connection, simple logic and the first screen on the Micro OCS panel. When working with X5 PRIME, select your exact model and the corresponding I/O in configuration.

Open YouTube tutorial

Your first test task

When first verifying, start with one simple function. For example, an output that switches on for a set time after pressing a button or changing the input signal.

  • Set the switching time on the display and show the input and output status.
  • Handle the trigger condition and timer in the program.
  • On the test load, verify switching on, switching off after a time has elapsed and changing the settings on the display.

Cscape training exercises from Horner

Photo gallery and connection

Click to open a separate image in a larger view.

Frequently asked questions

Do I need separate PLC or HMI?

X5 PRIME contains PLC, color touch screen and 12 built-in I/O. You don't need separate PLC and HMI for the same task. Next I/O depends on the required signals.

What is free and what is charged separately?

Standard Cscape is free with each panel. You can create the PLC program and the HMI screens without a paid programming license. Additional features have their own license terms. Free loan of selected products for 14 days is arranged individually according to availability. We will confirm the specific model, date and conditions in advance. Accessories, training and the work of technicians will be priced according to the scope.

How to decide between X5 PRIME and CANVAS 5?

Both models have a 4,3″ touch screen and a combination of 4 DI, 4 DO and 4 AI. CANVAS uses a different graphics system and has different communication function conditions. We will compare the required screens, communication, any existing project and the price of the necessary equipment.

Do I connect Pt100 directly or do I need an analog output?

The built-in analog channels are voltage/current inputs. For direct measurement of Pt100, thermocouple or for analog output, we select a suitable extension or other panel.

How can I check trial loan availability?

Click Arrange a trial loan and describe your application. We will check a suitable loan model, availability, dates and conditions. Trial loans of selected products are arranged individually.

Can you help with the first project?

We advise on the selection of equipment and offer training in Liberec for individuals and groups. If necessary, we will prepare the project design and assembly with our own technicians.

Why buy from FOXON

Distributor HORNER

We supply new HORNER products with warranty and will help you choose the right equipment and accessories.

Selection according to your project

We will discuss technology function, signals and communication. We will compare the entry with the HORNER options and select a suitable product.

Technical support and training

We advise on the use of the equipment and train individuals and groups. For self-study, we recommend the manufacturer's instructions.

Solution design and assembly

If necessary, we will design a solution, prepare a project and install the equipment with our own technicians. We will agree on the scope of work according to the technology.

More than 3 500customers
We deliver tomore than 100 countries of the world
Express delivery?We will check it, contact us immediately.

Video tutorials by topic

The videos were prepared by Horner. Translated titles and summaries explain their content. The videos are in English. General Cscape tutorials also use other panels; adapt the hardware configuration, I/O and licensed features to X5 PRIME.

First project and programming

  • First project with Micro OCSGet Started with Cscape 10 and Micro OCS
    Panel connection to PC, hardware configuration, simple program and first screen.Play video
  • Orientation in the Cscape 10 projectThe Cscape 10 Project Navigator
    Working with the project navigator and overview of its parts in Cscape 10.Play video
  • Programming in IEC 61131 languagesIEC 61131 Logic Programming in Cscape 10
    Introducing IEC control logic editor capabilities in Cscape 10.Play video
  • Uploading the program to the panelCscape 10 Program Downloads
    Program transfer options and procedures in Cscape 10.Play video

Display, screens and alarms

  • Creating and editing screensCscape 10 Graphics Editing
    Editing graphics and working with the screen editor in Cscape 10.Play video
  • Screen arrangement HMIScreen Organisation in Cscape
    Organization of multiple user screens in the Cscape project.Play video
  • Setting and using alarmsProgramming and using Alarms on the OCS
    Programming and use of fault and other alarm messages in OCS.Play video

Inputs, outputs and control

  • Signal conversion to pressure, temperature or levelAnalog IO Scaling in Cscape
    Conversion of analog sensor values to physical units in the program.Play video
  • Conditions by value, time and dateCompare Functions (Including LIMIT & Time/Date) in Cscape
    Comparison function including limits and working with time and date.Play video
  • Initial values of machine parametersUsing Setpoints with Horner Controllers
    Setting and transferring initial values of variables; the procedure depends on the selected language.Play video

Data logging, graphs and files

  • Setting up the recording of operating dataProgramming and using Datalogging on the OCS
    The basics of programming and using datalogging in the OCS control unit.Play video
  • Displaying trends in a graphUsing Trends on the Horner OCS
    Use of trends to display the evolution of monitored values.Play video
  • Management of recorded data filesTake Control of Horner Datalogging Files
    Working with files that are created when data is recorded on a storage medium.Play video
  • Reading and writing CSV, XML and TXT filesUsing Removable Media Functions in Cscape Part 2
    Creating and using custom data files. For X5 PRIME, use a supported storage medium; samples also include USB for other models.Play video

Program communication and protection

  • Modbus RTU setup and troubleshootingModbus RTU Master Setup & Troubleshooting
    Setting the role of master and finding problems in serial communication Modbus RTU.Play video
  • Data exchange via Modbus TCPUsing Modbus TCP for OCS to OCS Communication
    Example of connecting OCS controllers and exchanging data over Ethernet.Play video
  • Protection of the created programCscape Security: Protecting your IP in the Horner OCS
    Protecting your program in Cscape, including OEM Lock.Play video

Product series selection and communication

  • Comparison of XL PRIME and CANVASXL Prime vs Canvas – Which Should I Use?
    Comparison of equipment, graphics, communication and license terms of both series.Play video

Choose the procedures according to the series, equipment and version Cscape of your device.

First project, starter setup and support

Setup for initial commissioning

We will select a suitable power supply, connections and any external I/O for this panel. The quotation will itemise the hardware and optional start-up support. Standard Cscape is free.

Help with your project

We arrange consultation, configuration, programming or training in Liberec for individuals and groups. We will confirm the scope of work, output, price and deadline in advance.

The price of the entire assembly and services is on request. The price of the panel itself remains in the offer above. We select sensors and controlled elements according to the actual task.

Deployment examples HORNER

View specific deployments of HORNER X4 and X7 at machine manufacturers. The model used and the implementer are listed in the relevant study.

Try and choose for your task

Send technology function, necessary signals and deadline. We will check the possibility of a loan or discuss a suitable product and the price of the necessary equipment.

Properties HORNER X5 PRIME

On this page you order the HE-XP5 with a fixed combination of 4 digital inputs, 4 transistor outputs and 4 analog inputs. For a different number or type of signals, we will select a suitable extension or a different model.

Design and types of signals

HE-XP5

4 digital inputs, 4 transistor outputs and 4 analog inputs 0-10 V, 0-20 mA or 4-20 mA.

For smaller tasks with a color touch screen. It has no built-in relay or analog outputs.

Control system and hardware versions

ProgrammingCscape; Advanced Ladder and languages IEC 61131-3
Program memory2 MB
Cycle of logic0,02 ms/kB
Display4,3″ resistive touch, 65 thousand colours
Resolution and brightness480 × 272 px; 450 cd/m²
Screens and graphics memoryUp to 1 023 screens; 22 MB screen memory
Storage mediamicroSD in format FAT32; supported USB media via USB-A

Inputs and outputs

Digital inputs4; fast counters use the same input channels; 4 HSC to 500 kHz
Digital outputs4 transistorized; max 0,5 A per channel, max 2 A total
Analog inputs4; 0-10 V, 0-20 mA, 4-20 mA; 12 bits
Analog outputsThey are not built-in
Relay outputsThey are not built-in
Direct temperature inputsFor Pt100 or thermocouple, a corresponding external extension or converter is needed
Built-in analog inputs support 0-10 V, 0-20 mA and 4-20 mA; direct measurement of Pt100 and thermocouples is not their function. Set the current or voltage mode according to the connection and configuration. High-speed counters use the same four digital inputs. Transistor outputs are limited to 0,5 A per channel and 2 A in total; control the power load via the corresponding power element. X5 PRIME does not have built-in analog or relay outputs.

Ports and communication functions

Ethernet1× 10/100 Mb/s; for example Modbus TCP, FTP and ASCII
Serial ports1× RS232 and 1× two-wire RS485; common connector MJ1/2
CAN1×; specific protocol and firmware according to configuration
USB Mini-BPC connection for programming
USB-ASupported devices and storage media
License and Remote AccessStandard Cscape Free; We will verify WebMI, MQTT and other optional features according to requirements and license

Assembly and operating conditions

Power supply10-30 V DC
Typical current consumption118,1 mA at 24 V DC
Device dimensions (w x h x d)125 × 96 × 31 mm
Mounting cutout119,5 × 90,5 mm; tolerance ±0,5 mm
Device weight271 g
Operating temperature-10 to +60 °C
Storage temperature-30 to +70 °C
Relative humidity5-95 %, no condensation
Short power dropDuring a brief supply dip of approximately 100 ms, active outputs may remain on for approximately 1 second during restart. Take this into account when designing the power supply and control system.

Contents of delivery and accessories

HE-XP5 panel and mounting accessories. We will confirm the exact range of supplied connectors before ordering. Select the source, programming cable, memory medium and sensors separately according to the assembly.

24 V DC power supply and programming link USB Mini-B or Ethernet; separate items depending on the setup.

Accessories3