HORNER CANVAS 4 PLC HMI controller with 3.5″ colour touchscreen, analog / digital inputs and outputs - Type: No built-in I/O

HORNER CANVAS 4 PLC HMI controller with 3.5″ colour touchscreen, analog / digital inputs and outputs - Type: No built-in I/O

Software for free FOXON PLUS

Horner Automation

HORNER CANVAS 4 connects PLC, 3,5″ color touch screen and buttons. Six variants allow you to choose the necessary I/O; the -00 model is without built-in inputs and outputs. Cscape for PLC program and screens is free. FOXON will help with selection, first project and training.

Arrange a trial loan


More

Code: HE-CV-035C-00

881 EUR excl. VAT (1 066,01 EUR Incl. VAT)
Variant does not exist
Delivery in 1-2 weeks
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote

Horner Automation

HORNER CANVAS 4 connects PLC, 3,5″ color touch screen and buttons. Six variants allow you to choose the necessary I/O; the -00 model is without built-in inputs and outputs. Cscape for PLC program and screens is free. FOXON will help with selection, first project and training.

Arrange a trial loan


More

Code: HE-CV-035C-00

Options 6

Type Code Availability Price excl. VAT
No built-in I/O HE-CV-035C-00 Delivery in 1-2 weeks
881 EUR
12x DI (24 VDC, 4x HSC, 1 MHz), 6x DO relay (3 A), 4x AI (0-10 V, 0-20 mA, 4-20 mA, 12 bit) HE-CV-035C-02 In stock  2 pcs
930 EUR
12x DI (24 VDC, 4x HSC, 500 kHz), 12x DO (24 VDC, 2x PWM, 10 kHz), 2x AI (0-10 V, 0-20 mA, 4-20 mA, 12 bit) HE-CV-035C-03 Delivery in 1-2 weeks
1 061 EUR
24x DI (24 VDC, 4x HSC, 500 kHz), 16x DO (24 VDC, 2x PWM, 10 kHz), 2x AI (0-10 V, 0-20 mA, 4-20 mA, 12 bit) HE-CV-035C-04 Delivery in 1-2 weeks
1 118 EUR
12x DI (24 VDC, 4x HSC, 500 kHz), 12x DO (24 VDC, 2x PWM, 10 kHz), 2x AI (0-10 V, 100 mV, 0-20 mA, 4-20 mA, RTD, THM, 14/16 bit), 2x AO (0-10 V, 0-20 mA, 4-20 mA, 12 bit) HE-CV-035C-05 Delivery in 1-2 weeks
1 160 EUR
12x DI (24 VDC, 4x HSC, 500 kHz), 12x DO (24 VDC, 2x PWM, 10 kHz), 6x AI (0-10 V, 60 mV, 0-20 mA, 4-20 mA, RTD, THM, 17 bit), 4x AO (0-10 V, 0-20 mA, 4-20 mA, 12 bit) HE-CV-035C-06 Delivery in 1-2 weeks
1 314 EUR
HORNER CANVAS 4 · PLC + HMI · I/O according to variant

PLC and control in one panel. I/O according to your task.

HORNER CANVAS 4 combines PLC, 3,5″ color touch screen and five physical buttons. You control a small machine or fixture and monitor operating values ​​from one place. There are six designs on offer: from the model without built-in I/O to variants with digital, analog and temperature inputs.

Cscape 10 for both the PLC program and the HMI screens is free with each panel. You do not buy a programming license. In addition, CANVAS includes WebMI+, MQTT, Enhanced IEC and J1939 by default; external and cloud services have their own terms and conditions.

HORNER CANVAS 4 - device photo

Verify CANVAS 4 on your own task.
Free loan of selected products for 14 days is arranged individually according to availability. We will confirm the specific model, date and conditions in advance. FOXON will help with the selection and the first project.

3,5″ touch and buttons320 × 240 px and five physical keys
Six designs I/OFrom no built-in I/O to up to 42 built-in points
2 MB program memoryCscape 10 for both logic and screens

Introducing the CANVAS series

The short video Horner introduces the CANVAS series, its operation and basic equipment. It shows more models of the series. English.

Watch the introduction on YouTube

Applications in small machines and systems

Pump switching according to time or event

Starting at a specified time, running for a set time or reacting to a level and other input signal. The operator sets the values ​​and sees the pump status on the display.

Controlling a small machine or fixture

Starting the work cycle, continuity of individual steps and counting of pieces. The operator changes the length of the step or the number of repetitions on the panel.

Measurement and simple regulation

Display of pressure, temperature or other quantity and reaction to the set limit. The sensor type and signal range must match the selected built-in or extension I/O.

Local equipment monitoring

Input states, error messages and common settings on one display. You can prepare the range of screens and controls according to the specific device.

You create a function for your technology in Cscape. Select the necessary sensors and control elements according to the device.

Trial loan and training

Free loan by agreement

Free loan of selected products for 14 days is arranged individually according to availability. We will confirm the specific model, date and conditions in advance.

Training in Liberec

We train individuals and groups in our training room in Liberec. We will agree on the scope and date according to the experience of the participants and their tasks.

The original Horner Automation Europe video instructions are used for self-study. Translated titles and annotations explain their content, videos remain in English. Horner Europe video tutorials on YouTube

Selection of variant CANVAS 4

Select the version according to the list of signals. The basic HE-CV-035C-00 does not have a built-in I/O; other codes differ in their number and type. Prices and availability of a specific variant are listed above.

HE-CV-035C-00

No built-in inputs and outputs.

For control over a communication interface or with suitable expansion I/O.

HE-CV-035C-02

12 digital inputs, 6 relay outputs and 4 analog inputs (12 bits).

For tasks with relay contacts and measuring 0-10 V or current signals.

HE-CV-035C-03

12 digital inputs, 12 transistor outputs and 2 analog inputs (12 bits).

For control with transistor outputs and two analog signals.

HE-CV-035C-04

24 digital inputs, 16 transistor outputs and 2 analog inputs (12 bits).

For jobs with more digital signals; total 42 points I/O.

HE-CV-035C-05

12 digital inputs, 12 transistor outputs, 2 universal analog inputs and 2 analog outputs.

For measurements including Pt100 and thermocouples and for analog control.

HE-CV-035C-06

12 digital inputs, 12 transistor outputs, 6 universal analog inputs and 4 analog outputs.

For multiple analog and temperature signals as well as output values.

We will advise you on the selection of a suitable design and accessories according to the project.

Signal types and wiring limitations

The numbers and types of I/O refer to a specific order code. The -00 model does not have a built-in I/O. -02/-03/-04 models support 0-10 V, 0-20 mA and 4-20 mA analog inputs; direct measurement of Pt100 and thermocouples, choose -05/-06. For -05, the range is also selected using jumpers; -06 has its own connection of universal channels. The voltage and current terminals of the same analog output are not two independent channels. Quick features share selected digital channels. Check the connection, signal combination and current limits in the datasheet of the exact code.

Technical parameters HORNER CANVAS 4

Display and control3,5″ color touch, 320 × 240 px; 5 physical buttons
Program memory2 MB
Built-in I/OAccording to the variant: none to 42 points
ConnectionEthernet 10/100 Mb/s, RS232, RS485, CAN, USB Mini-B, USB-A, microSD
ProgrammingCscape 10 free; logic and screens in one project
Power supply10-30 V DC for standard design
Operating temperature-10 to +60 °C for standard design

You can find detailed information in the tab Features.

Connection and operation

CANVAS 4 has Ethernet, RS232 and RS485 on a shared connector, and a CAN port. It supports Modbus TCP and serial Modbus RTU communication, for example. We will select suitable modules and communication for remote I/O expansion. USB-A and microSD are used for data; USB Mini-B connects to a PC.

You can create logic and more advanced screens in the free Cscape 10. WebMI+, MQTT, Enhanced IEC and J1939 are standard on the CANVAS. When designing remote access, we will also verify the network, the necessary services and their conditions.

HORNER CANVAS 4 - photo of the device from the front
Photograph of the device from the front

Equipment and cost of first launch

Panel HORNER CANVAS 4Current price in the selection of variants above
Standard Cscape0 CZK - program PLC and screens HMI
Power supply and connection24 V DC source and USB Mini-B or Ethernet programming interface; separate items by assembly. For -00, add the necessary external I/O if the task requires them.
Sensors and controlsAccording to the signals and loads of your job
Training, design and assemblyPricing according to the agreed scope

The price of the panel is not the price of the entire automation. In the offer, we will discuss the necessary equipment and the possible work of technicians. We select the source, cables and other accessories according to the assembly.

Contents of the standard package

Panel in ordered design and mounting accessories. We will confirm the content of the connectors for the selected I/O model. Choose the power supply, programming cable, memory medium, sensors and external I/O according to the assembly; the -00 model does not have I/O built-in.

First project in Cscape

Download Cscape from Horner. You need a manufacturer account to download Cscape. The CANVAS tutorial shows PC connection, hardware configuration, control logic and creating the first screen.

Open YouTube tutorial

Your first test task

When first verifying, start with one simple function. For example, an output that switches on for a set time after pressing a button or changing the input signal.

  • Set the switching time on the display and show the input and output status.
  • Handle the trigger condition and timer in the program.
  • On the test load, verify switching on, switching off after a time has elapsed and changing the settings on the display.

Cscape training exercises from Horner

Photo gallery and connection

Click to open a separate image in a larger view.

Frequently asked questions

Do I need separate PLC or HMI?

CANVAS 4 contains both PLC and touch HMI. You do not need separate PLC and HMI for the same task. The built-in I/O depends on the code: -00 does not have them, other variants have different combinations of signals.

What is free and what is charged separately?

Standard Cscape is free with each panel. You can create the PLC program and the HMI screens without a paid programming license. Additional features have their own license terms. Free loan of selected products for 14 days is arranged individually according to availability. We will confirm the specific model, date and conditions in advance. Accessories, training and the work of technicians will be priced according to the scope.

Which design to choose for Pt100 or thermocouple?

For direct temperature measurement, select universal analog inputs of model -05 or -06. We compare the sensor type, number of channels and connection with the datasheet of the given variant.

Is the cheapest option ready for direct sensor connection?

The basic HE-CV-035C-00 has no built-in inputs and outputs. You then connect the sensors and controlled elements via suitable external I/O or choose another design CANVAS 4.

How can I check trial loan availability?

Click Arrange a trial loan and describe your application. We will check a suitable loan model, availability, dates and conditions. Trial loans of selected products are arranged individually.

Can you help with the first project?

We advise on the selection of equipment and offer training in Liberec for individuals and groups. If necessary, we will prepare the project design and assembly with our own technicians.

Why buy from FOXON

Distributor HORNER

We supply new HORNER products with warranty and will help you choose the right equipment and accessories.

Selection according to your project

We will discuss technology function, signals and communication. We will compare the entry with the HORNER options and select a suitable product.

Technical support and training

We advise on the use of the equipment and train individuals and groups. For self-study, we recommend the manufacturer's instructions.

Solution design and assembly

If necessary, we will design a solution, prepare a project and install the equipment with our own technicians. We will agree on the scope of work according to the technology.

More than 3 500customers
We deliver tomore than 100 countries of the world
Express delivery?We will check it, contact us immediately.

Video tutorials by topic

Videos prepared by Horner. Translated titles and annotations explain their content. The videos are in English; samples may use another model of the same series.

First project and programming

  • First project with CANVASGet Started with Cscape 10 and Canvas
    Panel connection, hardware configuration, logic programming and first screen.Play video
  • Orientation in the Cscape 10 projectThe Cscape 10 Project Navigator
    Working with the project navigator and overview of its parts in Cscape 10.Play video
  • Programming in IEC 61131 languagesIEC 61131 Logic Programming in Cscape 10
    Introducing IEC control logic editor capabilities in Cscape 10.Play video
  • Uploading the program to the panelCscape 10 Program Downloads
    Program transfer options and procedures in Cscape 10.Play video

Inputs, outputs and control

  • Signal conversion to pressure, temperature or levelAnalog IO Scaling in Cscape
    Conversion of analog sensor values to physical units in the program.Play video
  • Conditions by value, time and dateCompare Functions (Including LIMIT & Time/Date) in Cscape
    Comparison function including limits and working with time and date.Play video
  • Initial values of machine parametersUsing Setpoints with Horner Controllers
    Setting and transferring initial values of variables; the procedure depends on the selected language.Play video

Data logging, graphs and files

  • Setting up the recording of operating dataProgramming and using Datalogging on the OCS
    The basics of programming and using datalogging in the OCS control unit.Play video
  • Displaying trends in a graphUsing Trends on the Horner OCS
    Use of trends to display the evolution of monitored values.Play video
  • Management of recorded data filesTake Control of Horner Datalogging Files
    Working with files that are created when data is recorded on a storage medium.Play video

Program communication and protection

  • Modbus RTU setup and troubleshootingModbus RTU Master Setup & Troubleshooting
    Setting the role of master and finding problems in serial communication Modbus RTU.Play video
  • Data exchange via Modbus TCPUsing Modbus TCP for OCS to OCS Communication
    Example of connecting OCS controllers and exchanging data over Ethernet.Play video
  • Protection of the created programCscape Security: Protecting your IP in the Horner OCS
    Protecting your program in Cscape, including OEM Lock.Play video

Display, screens and alarms

  • Creation of CANVAS screensCanvas Graphics Overview in Cscape 10
    Overview of graphical objects for CANVAS: values, buttons, indicators and controls.Play video

Choose the procedures according to the series, equipment and version Cscape of your device.

First project, starter setup and support

Setup for initial commissioning

We will select a suitable power supply, connections and any external I/O for this panel. The quotation will itemise the hardware and optional start-up support. Standard Cscape is free.

Help with your project

We arrange consultation, configuration, programming or training in Liberec for individuals and groups. We will confirm the scope of work, output, price and deadline in advance.

The price of the entire assembly and services is on request. The price of the panel itself remains in the offer above. We select sensors and controlled elements according to the actual task.

Deployment examples HORNER

View specific deployments of HORNER X4 and X7 at machine manufacturers. The model used and the implementer are listed in the relevant study.

Try and choose for your task

Send technology function, necessary signals and deadline. We will check the possibility of a loan or discuss a suitable product and the price of the necessary equipment.

Properties HORNER CANVAS 4

Select the version according to the list of signals. The basic HE-CV-035C-00 does not have a built-in I/O; other codes differ in their number and type. Prices and availability of a specific variant are listed above.

Design and types of signals

HE-CV-035C-00

No built-in inputs and outputs.

For control over a communication interface or with suitable expansion I/O.

HE-CV-035C-02

12 digital inputs, 6 relay outputs and 4 analog inputs (12 bits).

For tasks with relay contacts and measuring 0-10 V or current signals.

HE-CV-035C-03

12 digital inputs, 12 transistor outputs and 2 analog inputs (12 bits).

For control with transistor outputs and two analog signals.

HE-CV-035C-04

24 digital inputs, 16 transistor outputs and 2 analog inputs (12 bits).

For jobs with more digital signals; total 42 points I/O.

HE-CV-035C-05

12 digital inputs, 12 transistor outputs, 2 universal analog inputs and 2 analog outputs.

For measurements including Pt100 and thermocouples and for analog control.

HE-CV-035C-06

12 digital inputs, 12 transistor outputs, 6 universal analog inputs and 4 analog outputs.

For multiple analog and temperature signals as well as output values.

Control system and hardware versions

ProgrammingCscape 10; Advanced Ladder and languages IEC 61131-3
Program memory2 MB
Cycle of logic0,02 ms/kB
Display3,5″ TFT; 65 thousand colours; touch control
Resolution and brightness320 × 240 px; 640 cd/m²
Physical buttons5
ScreensUp to 1 023 screens; up to 1 023 objects on the screen
Storage mediamicroSD up to 32 GB, FAT32; USB flash drive via USB-A

Inputs and outputs

Model -00Without built-in I/O
Model -0212 DI / 6 relays / 4 AI (12 bits)
Model -0312 DI / 12 DO / 2 AI (12 bits)
Model -0424 DI / 16 DO / 2 AI (12 bits)
Analog Inputs -02/-03/-040-10 V, 0-20 mA, 4-20 mA
Model -0512 DI / 12 DO / 2 universal AI / 2 AO
Analog signals -05AI: 0-10 V, 0-20 mA, 4-20 mA, mV, Pt100 and thermocouples J/K/N/T/E/R/S/B; resolution 14 bits for V/mA/mV, 16 bits for temperature. AO: 0-10 V or 0-20 mA, 12 bits.
Model -0612 DI / 12 DO / 6 universal AI / 4 AO
Analog signals -06AI: 0-10 V, 0-20 mA, 4-20 mA, mV, Pt100/Pt1000 and ungrounded thermocouples J/K/N/T/E/R/S/B; 17 bits. AO: 0-10 V, 0-20 mA, 4-20 mA; 12 bits.
The numbers and types of I/O refer to a specific order code. The -00 model does not have a built-in I/O. -02/-03/-04 models support 0-10 V, 0-20 mA and 4-20 mA analog inputs; direct measurement of Pt100 and thermocouples, choose -05/-06. For -05, the range is also selected using jumpers; -06 has its own connection of universal channels. The voltage and current terminals of the same analog output are not two independent channels. Quick features share selected digital channels. Check the connection, signal combination and current limits in the datasheet of the exact code.

Ports and communication functions

Ethernet1× 10/100 Mb/s; for example Modbus TCP, FTP, SMTP and ASCII
Serial ports1× RS232 and 1× RS485; common connector MJ1/2
CAN1×; CsCAN, CANopen, DeviceNet and J1939 depending on configuration
USB Mini-BPC connection for programming and data access
USB-AUSB host for supported devices and storage media
Web and data transferWebMI+ and MQTT; setting in Cscape 10
Expanding I/OSelection according to the required signals, bus and project configuration

Assembly and operating conditions

Standard design power supply10-30 V DC
Front dimensions96 × 96 mm; depth according to I/O design and installed accessories
Mounting cutout92 × 92 mm; tolerance ±0,1 mm
Base unit weight without I/O340 g; the weight of the complete variant depends on I/O
Operating temperature of the standard design-10 to +60 °C
Storage temperature-20 to +60 °C
Relative humidity5-95 %, no condensation

Contents of delivery and accessories

Panel in ordered design and mounting accessories. We will confirm the content of the connectors for the selected I/O model. Choose the power supply, programming cable, memory medium, sensors and external I/O according to the assembly; the -00 model does not have I/O built-in.

24 V DC source and USB Mini-B or Ethernet programming interface; separate items by assembly. For -00, add the necessary external I/O if the task requires them.

Accessories3