HORNER X4 PLC HMI controller with 4.3″ colour touchscreen, analog / digital inputs and outputs - Type: 12x DI (24 VDC, 4x HSC, 500 kHz), 12x DO (24 VDC, 2x PWM, 65 kHz), 4x AI (0-20 mA, 4-20 mA, PT100 RTD, 12 bit), 2x AO (4-20 mA, 12 bit)

HORNER X4 PLC HMI controller with 4.3″ colour touchscreen, analog / digital inputs and outputs - Type: 12x DI (24 VDC, 4x HSC, 500 kHz), 12x DO (24 VDC, 2x PWM, 65 kHz), 4x AI (0-20 mA, 4-20 mA, PT100 RTD, 12 bit), 2x AO (4-20 mA, 12 bit)

Software for free FOXON PLUS

Horner Automation

PLC, color touch screen 4,3″ and I/O in one panel for small machines and technology. You can create the program and screens in Cscape for free. We will check the possibility of free loan of selected products for 14 days by agreement according to availability. FOXON will help with the selection and the first project.

Arrange a trial loan

More

Code: HE-X4A

464 EUR excl. VAT (561,44 EUR Incl. VAT)
Variant does not exist
Delivery in 1-2 weeks
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote

Horner Automation

PLC, color touch screen 4,3″ and I/O in one panel for small machines and technology. You can create the program and screens in Cscape for free. We will check the possibility of free loan of selected products for 14 days by agreement according to availability. FOXON will help with the selection and the first project.

Arrange a trial loan

More

Code: HE-X4A

Options 2

Type Code Availability Price excl. VAT
12x DI (24 VDC, 4x HSC, 500 kHz), 12x DO (24 VDC, 2x PWM, 65 kHz), 4x AI (0-20 mA, 4-20 mA, PT100 RTD, 12 bit), 2x AO (4-20 mA, 12 bit) HE-X4A Delivery in 1-2 weeks
464 EUR
12x DI (24 VDC, 4x HSC, 500 kHz), 2x DO (24 VDC, 2x PWM, 65 kHz), 6x DO relay (3 A), 4x AI (0-20 mA, 4-20 mA, PT100 RTD, 12 bit), 2x AO (4-20 mA, 12 bit) HE-X4R Delivery in 1-2 weeks
464 EUR
HORNER X4 · PLC + HMI + I/O

PLC, control and I/O
in one panel.

Compact control for small machines, pumps and fixtures. The panel reads signals, switches outputs according to your program and allows you to change settings on the color touch screen.

Standard Cscape is free with each panel. In one environment, you create the PLC program and the HMI screens without a paid programming license.

HORNER X4 - compact control panel with color touch screen

Option to try X4
Free loan of selected products for 14 days is arranged individually according to availability. We will confirm the specific model, date and conditions in advance. FOXON will help with the selection and the first project.

4,3″ touch screen480 × 272 px for machine settings, states and alarms.
30 I/O at HE-X4A12 DI, 12 DO, 4 AI and 2 AO. Other variants have a different composition.
Ethernet + RS + CANConnection of peripherals and extensions according to the selected protocol.

Introducing the X4 panel

The Horner APG product video presents the X4 panel. The video is in English.

Watch the X4 introduction on YouTube

Applications in small machines and systems

Pump switching according to time or event

Starting at a specified time, running for a set time or reacting to a level and other input signal. The operator sets the values ​​and sees the pump status on the display.

Controlling a small machine or fixture

Starting the work cycle, continuity of individual steps and counting of pieces. The operator changes the length of the step or the number of repetitions on the panel.

Measurement and simple regulation

Display of pressure, temperature or other quantity and reaction to the set limit. The sensor type and signal range must match the selected panel inputs.

Local equipment monitoring

Input states, error messages and common settings on one display. You can prepare the range of screens and controls according to the specific device.

You create a function for your technology in Cscape. Select sensors, power and safety elements according to the device.

Trial loan and training

Free loan by agreement

Free loan of selected products for 14 days is arranged individually according to availability. We will confirm the specific model, date and conditions in advance.

Training in Liberec and self-study

In our training room in Liberec, we will train you in the programming of HORNER panels in Cscape. An individual or a group of colleagues can come. We will agree on the scope and date of the training according to your experience and the required task.

You can also start yourself by following the video tutorials of Horner Automation Europe. They show the work in Cscape, the connection of the panel and the first program. The videos are in English. Horner Europe video tutorials on YouTube

Selection of variant X4

The available order options are HE-X4A and HE-X4R. A has transistor outputs, R combines relay and transistor outputs.

HE-X4A

12× DI · 12× transistor DO

4× AI: 0/4-20 mA or Pt100 · 2× AO: 4-20 mA

For 24 V DC signals, current sensors and regulation with 4-20 mA output.

HE-X4R

12× DI · 6× relay DO + 2× transistor DO

4× AI: 0/4-20 mA or Pt100 · 2× AO: 4-20 mA

When you need relay contacts and analogue current signals.

For signals 0-10 V, the voltage versions HE-X4R-V20 or HE-X4R-V42 are solved individually on demand. We will check their price and availability according to the specification. Standard A/Rs have current analog inputs or Pt100.
Pt100 wiring and concurrency of analog channels

For HE-X4A and HE-X4R, the use of analog channels depends on the connection. The four-wire Pt100 uses two channels per sensor; with four two-wire Pt100, there are no analog outputs. Therefore, check the necessary concurrence of measurements and outputs before making a selection.

Technical parameters HORNER X4

Display4,3″ color touch, 480 × 272 px
Program memory256 kB for control logic
Built-in I/OHE-X4A: 30 points; HE-X4R, V20 and V42: 26 points. Analog signal types vary.
Power supply24 V DC ±20 %
Communication1× Ethernet, 1× RS232, 1× RS485, 1× CAN; USB Mini-B for programming
Mounting and dimensionsPanel mounting; 125 × 96 × 31 mm (W × H × D), cutout 119.5 × 90.5 mm

You can find the exact number of signals, connections and conditions for a specific design in the tab Features. Select the documentation according to the entire order number.

Connections and operator screens

Via Modbus TCP or Modbus RTU you connect the corresponding peripherals. CsCAN is also used for supported remote I/O. Select a specific device according to the protocol and signals.

You prepare the buttons, settings, statuses and alarms of your machine on the display. CANopen, BACnet/IP and the WebMI extension have their own license terms.

Example of color visualization on HORNER X4 display
Screen shot. You design the HMI content for your task.

Equipment and cost of first launch

Panel HORNER X4Current price in the selection of variants above
Standard Cscape0 CZK - program PLC and screens HMI
Power supply and connection24 V DC source and USB Mini-B or Ethernet cable - separate items according to assembly
Sensors and controlsAccording to the signals and loads of your job
Training, design and assemblyPricing according to the agreed scope

The price of the panel is not the price of the entire automation. In the offer, we will discuss the necessary equipment and the possible work of technicians. The power supply and cables are not part of the standard package.

Contents of the standard package
  • Panel in the selected design.
  • Three I/O connectors and a power connector.
  • Four mounting clips and a quick guide.

First project in Cscape

Download free Cscape from Horner - you need a manufacturer account to download. The video shows PC connection, hardware configuration, simple program and HMI screen.

English · 28 min. Open YouTube tutorial

Your first test task

When first verifying, start with one simple function. For example, an output that switches on for a set time after pressing a button or changing the input signal.

  • Set the switching time on the display and show the input and output status.
  • Handle the trigger condition and timer in the program.
  • On the test load, verify switching on, switching off after a time has elapsed and changing the settings on the display.

Cscape training exercises from Horner

Panel and connection photo gallery

View the front design, rear terminals and panel profile. Click to open a separate image in a larger view.

Frequently asked questions

Do I need separate PLC or HMI?

X4 contains PLC, touch screen and built-in I/O. You choose the extension according to the signals and requirements of the task.

What is free and what is charged separately?

Standard Cscape is free. Free loan of selected products for 14 days is arranged individually according to availability. We will confirm the specific model, date and conditions in advance. We will assess the necessary accessories, any additional licenses, training and the work of the technicians in the offer according to the scope.

Do I connect sensor 0-10 V to HE-X4A or HE-X4R?

Standard A/Rs have current analog inputs or Pt100. For 0-10 V, voltage version V20 or V42 is selected; We will check availability and price upon request.

How can I check trial loan availability?

Click Arrange a trial loan and describe your application. We will check a suitable loan model, availability, dates and conditions. Trial loans of selected products are arranged individually.

Can you help with the first project?

We advise on the selection of equipment and offer training in Liberec for individuals and groups. If necessary, we will prepare the project design and assembly with our own technicians.

Why buy from FOXON

Distributor HORNER

We are a distributor of HORNER. We supply new products with warranty and help you choose the right panel and accessories.

Selection according to your project

We will discuss machine function, signals and required communication. We will compare your entry with HORNER options and select a suitable product.

Technical support and training

We advise on the use of the device. In Liberec, we train individuals and groups in programming in Cscape; for self-study, use the manufacturer's video instructions.

Solution design and assembly

If necessary, we will design a solution, prepare a project and install the equipment with our own technicians. We will agree on the scope of work according to your technology.

Before ordering, we will verify the suitability of the selected design for your specification and confirm the delivery date. We supply new products with warranty.

More than 3 500customers
We deliver tomore than 100 countries of the world
Express delivery?We will check it, contact us immediately.

Video tutorials by topic

Select the topic you are currently solving. The videos were prepared by Horner Automation Europe and are in English. Translated titles and brief descriptions will make it easier to choose the manual.

First project and programming

  • First project with Micro OCSGet Started with Cscape 10 and Micro OCS
    Panel connection to PC, hardware configuration, simple program and first screen.
    Play video
  • Orientation in the Cscape 10 projectThe Cscape 10 Project Navigator
    Working with the project navigator and overview of its parts in Cscape 10.
    Play video
  • Programming in IEC 61131 languagesIEC 61131 Logic Programming in Cscape 10
    Introducing IEC control logic editor capabilities in Cscape 10.
    Play video
  • Uploading the program to the panelCscape 10 Program Downloads
    Program transfer options and procedures in Cscape 10.
    Play video

Display, screens and alarms

  • Creating and editing screensCscape 10 Graphics Editing
    Editing graphics and working with the screen editor in Cscape 10.
    Play video
  • Screen arrangement HMIScreen Organisation in Cscape
    Organization of multiple user screens in the Cscape project.
    Play video
  • Setting and using alarmsProgramming and using Alarms on the OCS
    Programming and use of fault and other alarm messages in OCS.
    Play video

Inputs, outputs and control

  • Connecting signals to Micro OCSHorner Micro OCS I/O Tips and Tricks
    Tips for working with I/O series Micro OCS; compare the connection with the datasheet of your variant.
    Play video
  • Signal conversion to pressure, temperature or levelAnalog IO Scaling in Cscape
    Conversion of analog sensor values to physical units in the program.
    Play video
  • Conditions by value, time and dateCompare Functions (Including LIMIT & Time/Date) in Cscape
    Comparison function including limits and working with time and date.
    Play video
  • Initial values of machine parametersUsing Setpoints with Horner Controllers
    Setting and transferring initial values of variables; the procedure depends on the selected language.
    Play video

Data logging, graphs and files

  • Setting up the recording of operating dataProgramming and using Datalogging on the OCS
    The basics of programming and using datalogging in the OCS control unit.
    Play video
  • Displaying trends in a graphUsing Trends on the Horner OCS
    Use of trends to display the evolution of monitored values.
    Play video
  • Management of recorded data filesTake Control of Horner Datalogging Files
    Working with files that are created when data is recorded on a storage medium.
    Play video
  • Reading and writing CSV, XML and TXT filesUsing Removable Media Functions in Cscape Part 2
    Creating and using custom data files. For X4, work with microSD; samples also include USB for other models.
    Play video

Program communication and protection

  • Modbus RTU setup and troubleshootingModbus RTU Master Setup & Troubleshooting
    Setting the role of master and finding problems in serial communication Modbus RTU.
    Play video
  • Data exchange via Modbus TCPUsing Modbus TCP for OCS to OCS Communication
    Example of connecting OCS controllers and exchanging data over Ethernet.
    Play video
  • Protection of the created programCscape Security: Protecting your IP in the Horner OCS
    Protecting your program in Cscape, including OEM Lock.
    Play video

Full channel Horner Automation Europe on YouTube

The samples use different OCS models and Cscape versions. Refer the procedure to the equipment of your panel; for older videos, the appearance of the environment is different from the current version.

First project, starter setup and support

Setup for initial commissioning

We will select a suitable power supply, connections and any external I/O for this panel. The quotation will itemise the hardware and optional start-up support. Standard Cscape is free.

Help with your project

We arrange consultation, configuration, programming or training in Liberec for individuals and groups. We will confirm the scope of work, output, price and deadline in advance.

The price of the entire assembly and services is on request. The price of the panel itself remains in the offer above. We select sensors and controlled elements according to the actual task.

Deployment examples HORNER

X4 in a modernized machine

W&K-Automation used HORNER X4 and external I/O in upgrading a sheet metal cleaning machine. Read the deployment example published on FOXON.

Read case study X4

Try and choose for your task

Send machine function, necessary signals and deadline. We will check the loan option or discuss a suitable panel and the price of the entire assembly.

Properties HORNER X4

Parameters for selecting a variant, designing the wiring and mounting in a control cabinet. Compare the signal types first, then the I/O count.

Order HE-X4A and HE-X4R in the selection on this page. We deal with voltage versions V20 and V42 individually upon request; we will check the price and availability.
Standard Cscape is free with every HORNER panel. You do not need a paid license to program PLC and create HMI screens.

Design and types of signals

HE-X4A

12× DI · 12× transistor DO

4× AI: 0/4-20 mA or Pt100 · 2× AO: 4-20 mA

For 24 V DC signals, current sensors and regulation with 4-20 mA output.

HE-X4R

12× DI · 6× relay DO + 2× transistor DO

4× AI: 0/4-20 mA or Pt100 · 2× AO: 4-20 mA

When you need relay contacts and analogue current signals.

HE-X4R-V20

12× DI · 6× relay DO + 2× transistor DO

2× AI: 0-10 V + 2× AI: 0/4-20 mA or Pt100 · 2× AO: 4-20 mA

For a combination of voltage and current sensors.

HE-X4R-V42

12× DI · 6× relay DO + 2× transistor DO

4× AI: 0-10 V · 2× AO: 0-10 V

When both the sensors and the controlled elements work with voltage 0-10 V.

For HE-X4A and HE-X4R, the use of analog channels depends on the connection. The four-wire Pt100 uses two channels per sensor; with four two-wire Pt100, there are no analog outputs. Therefore, check the necessary concurrence of measurements and outputs before making a selection.

PLC, display and operating conditions

Manufacturer and seriesHorner Automation, Micro OCS X4
Device typePLC with built-in HMI and I/O
Display4,3″ color TFT, 480 × 272 px, touch control
Brightness / colors350 cd/m²; 65 thousand colours
Screens and objectsUp to 250 user screens, up to 100 objects per screen
Control logic memory256 kB
ProgrammingCscape; Advanced Ladder Logic and languages IEC 61131-3
Power supply24 V DC ±20 %
Typical current consumption190 mA at 24 V DC and 100% backlight
Operating temperature-10 to +60 °C
Storage temperature-20 to +70 °C
Humidity5 to 95 %, non-condensing
Panel weight360 g
Dimensions W x H x D125 × 96 × 31 mm
Mounting cutout119,5 × 90,5 mm; tolerance ±0,5 mm
FasteningMounting in the panel using four clips
Storage mediummicroSD slot; choose the card separately

Digital and analog signals

Digital inputs12; positive or negative logic according to wiring and configuration
High-speed counters4 of the digital inputs are usable as HSC, up to 500 kHz
PWM2 from the transistor outputs, up to 65 kHz
HE-X4A - transistor outputs12, switching to the positive branch (sourcing); max 0,5 A to output at 24 V DC
HE-X4R - transistor outputs2; sinking with internal pull-up. Load capacity depends on the wiring; do not confuse these with model A outputs.
HE-X4R - relays6; max 3 A at 30 V DC or 60 V AC for resistive load, max total current 5 A
HE-X4A and HE-X4R - analog inputs4; 0-20 mA, 4-20 mA or Pt100 depending on configuration, nominal 12 bit resolution
Pt100 in HE-X4A and HE-X4RRange -50 to +200 °C; the number of sensors and the availability of the AO depend on the two-, three- or four-wire connection
HE-X4A and HE-X4R - analog outputs2; 4-20 mA, nominal 12 bit resolution, maximum load 500 Ω at 20 mA
Check the limits for load and concurrency of signals in the datasheet of the respective model. HSC and PWM are alternative functions of selected I/O, they do not add additional physical inputs and outputs.

Ports and communication functions

Ethernet LAN1× RJ45, 10/100 Mb/s
Serial interfaces1× RS232 + 1× RS485, shared connector MJ1/2
CAN1× CAN via RJ45; CsCAN network. This is not an Ethernet port.
USB Mini-BFor programming, not USB-A flash drive port
ModbusModbus TCP via Ethernet and Modbus RTU via serial interface according to configuration
Extension I/ORemote modules supported via CsCAN or Modbus; the specific assembly needs to be verified
CANopen and BACnet/IPAdditional Licenses; required firmware version and Cscape according to license terms
Web controlWebMI; Check the function scope, license and firmware compatibility for a specific request

Assembly and connection

HORNER X4 - rear side with I/O connection and communication ports
  • Dimension the power supply and load I/O separately according to the connection.
  • Distinguish LAN, CAN, and serial ports by the label, not just by the shape of the RJ45 connector.
  • Check the cut-out and fasteners before making the cabinet door.
  • Select diagrams and terminals according to the entire order number.

What you get and what to add

Standard packaging includes a panel, three I/O connectors, a power connector, four mounting clips and a quick guide. Select the 24 V DC source, programming cable, microSD, sensors and power elements separately.

Accessories3