HORNER X7 PLC HMI controller with 7″ colour touchscreen, analog / digital inputs and outputs - Type: 12x DI (24 VDC, 4x HSC, 500 kHz), 12x DO (24 VDC, 2x PWM, 65 kHz), 4x AI (0-20 mA, 4-20 mA, PT100 RTD, 12 bit), 2x AO (4-20 mA, 12 bit)

HORNER X7 PLC HMI controller with 7″ colour touchscreen, analog / digital inputs and outputs - Type: 12x DI (24 VDC, 4x HSC, 500 kHz), 12x DO (24 VDC, 2x PWM, 65 kHz), 4x AI (0-20 mA, 4-20 mA, PT100 RTD, 12 bit), 2x AO (4-20 mA, 12 bit)

Software for free FOXON PLUS

Horner Automation

HORNER X7 combines PLC, 7″ color touch screen and built-in I/O to control small machines and technologies. Cscape for PLC program and screens is free. FOXON will help with selection, first project and training.

Arrange a trial loan


More

Code: HE-X7A

774 EUR excl. VAT (936,54 EUR Incl. VAT)
Variant does not exist
Delivery in 1-2 weeks
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote

Horner Automation

HORNER X7 combines PLC, 7″ color touch screen and built-in I/O to control small machines and technologies. Cscape for PLC program and screens is free. FOXON will help with selection, first project and training.

Arrange a trial loan


More

Code: HE-X7A

Options 2

Type Code Availability Price excl. VAT
12x DI (24 VDC, 4x HSC, 500 kHz), 12x DO (24 VDC, 2x PWM, 65 kHz), 4x AI (0-20 mA, 4-20 mA, PT100 RTD, 12 bit), 2x AO (4-20 mA, 12 bit) HE-X7A Delivery in 1-2 weeks
774 EUR
12x DI (24 VDC, 4x HSC, 500 kHz), 2x DO (24 VDC, 2x PWM, 65 kHz), 6x DO relay (3 A), 4x AI (0-20 mA, 4-20 mA, PT100 RTD, 12 bit), 2x AO (4-20 mA, 12 bit) HE-X7R Delivery in 1-2 weeks
774 EUR
HORNER X7 · PLC + HMI + I/O

PLC, control and I/O in one panel.

HORNER X7 connects PLC, 7″ color touch screen and built-in inputs and outputs. From one place, you collect signals, control a small machine or fixture and change technology settings. A larger screen than the X4 will provide more space for operation and an overview of values.

Standard Cscape is free with each panel. You can create the PLC program and the HMI screens without a paid programming license. Additional features have their own license terms.

HORNER X7 - device photo

Verify X7 on your own task.
Free loan of selected products for 14 days is arranged individually according to availability. We will confirm the specific model, date and conditions in advance. FOXON will help with the selection and the first project.

7″ color touch800 × 480 px to control and display values
Two variants of I/OTransistor outputs A or relay design R
Ethernet, serial ports and CANConnecting communication and expanding I/O

Introducing X7

Short product video Horner presents X7. The player is ready to start; the video is in English.

Watch the introduction on YouTube

Applications in small machines and systems

Pump switching according to time or event

Starting at a specified time, running for a set time or reacting to a level and other input signal. The operator sets the values ​​and sees the pump status on the display.

Controlling a small machine or fixture

Starting the work cycle, continuity of individual steps and counting of pieces. The operator changes the length of the step or the number of repetitions on the panel.

Measurement and simple regulation

Display of pressure, temperature or other quantity and reaction to the set limit. The sensor type and signal range must match the selected panel inputs.

Local equipment monitoring

Input states, error messages and common settings on one display. You can prepare the range of screens and controls according to the specific device.

You create a function for your technology in Cscape. Select the necessary sensors and control elements according to the device.

Trial loan and training

Free loan by agreement

Free loan of selected products for 14 days is arranged individually according to availability. We will confirm the specific model, date and conditions in advance.

Training in Liberec

We train individuals and groups in our training room in Liberec. We will agree on the scope and date according to the experience of the participants and their tasks.

The original Horner Automation Europe video instructions are used for self-study. Translated titles and annotations explain their content, videos remain in English. Horner Europe video tutorials on YouTube

Selection of variant X7

In the menu above, you choose from two designs X7. It is mainly the type of outputs that decides; analog inputs and outputs are the same for both variants.

HE-X7A

12 digital inputs, 12 transistor outputs, 4 analog inputs and 2 analog outputs.

For tasks with transistor outputs; two support PWM to 65 kHz.

HE-X7R

12 digital inputs, 6 relay and 2 transistor/PWM outputs, 4 analog inputs and 2 analog outputs.

For tasks requiring relay contacts. Two transistor outputs support PWM to 10 kHz.

We will advise you on the selection of a suitable design and accessories according to the project.

Signal types and wiring limitations

Analog inputs support 0 - 20 mA , 4 - 20 mA or Pt100 (- 50 to + 200 °C); these are not inputs 0 - 10 V . The method of connection Pt100 and the use of terminals is different from the current measurement. The two analog outputs are 4 - 20 mA . The high-speed counters share four digital inputs and the PWM shares two transistor outputs. Check load limits, common terminals and wiring for A or R in the datasheet. Control the pump or motor via a power element suitable for the given load.

Technical parameters HORNER X7

Display7″ color touch, 800 × 480 px
Program memory256 kB
Built-in I/OA: 12 DI / 12 DO / 4 AI / 2 AO; R: 12 DI / 6 relay + 2 DO / 4 AI / 2 AO
Analog signalsAI: 0-20 mA, 4-20 mA or Pt100; AO: 4-20 mA
ConnectionEthernet 10/100 Mb/s, RS232, RS485, CAN, USB Mini-B, microSD
Power supply24 V DC ±20 %
Operating temperature-10 to +60 °C

You can find detailed information in the tab Features.

Connection and operation

X7 has Ethernet 10/100 Mb/s, RS232 and RS485 in a common connector MJ1/2 and a CAN port for CsCAN and corresponding expansion I/O. USB Mini-B is used for programming, microSD for storing and transferring data.

You create the control program and screens in Cscape. Choose protocols and remote access according to the specific feature and its license; Do not consider CANopen, BACnet and extended WebMI as an automatic part of free programming. We will verify the necessary combination before ordering.

HORNER X7 - photo of the device from the front
Photograph of the device from the front

Equipment and cost of first launch

Panel HORNER X7Current price in the selection of variants above
Standard Cscape0 CZK - program PLC and screens HMI
Power supply and connectionSource 24 V DC and programming cable USB Mini-B or Ethernet; separate items by assembly.
Sensors and controlsAccording to the signals and loads of your job
Training, design and assemblyPricing according to the agreed scope

The price of the panel is not the price of the entire automation. In the offer, we will discuss the necessary equipment and the possible work of technicians. We select the source, cables and other accessories according to the assembly.

Contents of the standard package

Panel in selected design and mounting clips. We will confirm the exact range of connectors and accessories for the supplied version. Choose the source, programming cable and sensors separately.

First project in Cscape

Download Cscape from Horner. You need a manufacturer account to download. The video shows PC connection, hardware configuration, simple program and HMI Micro OCS series screen.

Open YouTube tutorial

Your first test task

When first verifying, start with one simple function. For example, an output that switches on for a set time after pressing a button or changing the input signal.

  • Set the switching time on the display and show the input and output status.
  • Handle the trigger condition and timer in the program.
  • On the test load, verify switching on, switching off after a time has elapsed and changing the settings on the display.

Cscape training exercises from Horner

Photo gallery and connection

Click to open a separate image in a larger view.

Frequently asked questions

Do I need separate PLC or HMI?

X7 contains PLC, touch screen and built-in I/O. So you don't need separate PLC and HMI for the same task. The extension depends on the number and type of signals needed.

What is free and what is charged separately?

Standard Cscape is free with each panel. You can create the PLC program and the HMI screens without a paid programming license. Additional features have their own license terms. Free loan of selected products for 14 days is arranged individually according to availability. We will confirm the specific model, date and conditions in advance. Accessories, training and the work of technicians will be priced according to the scope.

Do I connect sensor 0-10 V?

HE-X7A and HE-X7R have current or Pt100 analog inputs. For 0-10 V sensor, another suitable I/O or design modification is needed. Send the sensor type and we will design the corresponding connection.

How can I check trial loan availability?

Click Arrange a trial loan and describe your application. We will check a suitable loan model, availability, dates and conditions. Trial loans of selected products are arranged individually.

Can you help with the first project?

We advise on the selection of equipment and offer training in Liberec for individuals and groups. If necessary, we will prepare the project design and assembly with our own technicians.

Why buy from FOXON

Distributor HORNER

We supply new HORNER products with warranty and will help you choose the right equipment and accessories.

Selection according to your project

We will discuss technology function, signals and communication. We will compare the entry with the HORNER options and select a suitable product.

Technical support and training

We advise on the use of the equipment and train individuals and groups. For self-study, we recommend the manufacturer's instructions.

Solution design and assembly

If necessary, we will design a solution, prepare a project and install the equipment with our own technicians. We will agree on the scope of work according to the technology.

More than 3 500customers
We deliver tomore than 100 countries of the world
Express delivery?We will check it, contact us immediately.

Video tutorials by topic

Videos prepared by Horner. Translated titles and annotations explain their content. The videos are in English; samples may use another model of the same series.

First project and programming

  • First project with Micro OCSGet Started with Cscape 10 and Micro OCS
    Panel connection to PC, hardware configuration, simple program and first screen.Play video
  • Orientation in the Cscape 10 projectThe Cscape 10 Project Navigator
    Working with the project navigator and overview of its parts in Cscape 10.Play video
  • Programming in IEC 61131 languagesIEC 61131 Logic Programming in Cscape 10
    Introducing IEC control logic editor capabilities in Cscape 10.Play video
  • Uploading the program to the panelCscape 10 Program Downloads
    Program transfer options and procedures in Cscape 10.Play video

Display, screens and alarms

  • Creating and editing screensCscape 10 Graphics Editing
    Editing graphics and working with the screen editor in Cscape 10.Play video
  • Screen arrangement HMIScreen Organisation in Cscape
    Organization of multiple user screens in the Cscape project.Play video
  • Setting and using alarmsProgramming and using Alarms on the OCS
    Programming and use of fault and other alarm messages in OCS.Play video

Inputs, outputs and control

  • Connecting signals to Micro OCSHorner Micro OCS I/O Tips and Tricks
    Tips for working with I/O series Micro OCS; compare the connection with the datasheet of your variant.Play video
  • Signal conversion to pressure, temperature or levelAnalog IO Scaling in Cscape
    Conversion of analog sensor values to physical units in the program.Play video
  • Conditions by value, time and dateCompare Functions (Including LIMIT & Time/Date) in Cscape
    Comparison function including limits and working with time and date.Play video
  • Initial values of machine parametersUsing Setpoints with Horner Controllers
    Setting and transferring initial values of variables; the procedure depends on the selected language.Play video

Data logging, graphs and files

  • Setting up the recording of operating dataProgramming and using Datalogging on the OCS
    The basics of programming and using datalogging in the OCS control unit.Play video
  • Displaying trends in a graphUsing Trends on the Horner OCS
    Use of trends to display the evolution of monitored values.Play video
  • Management of recorded data filesTake Control of Horner Datalogging Files
    Working with files that are created when data is recorded on a storage medium.Play video
  • Reading and writing CSV, XML and TXT filesUsing Removable Media Functions in Cscape Part 2
    Creating and using custom data files. For X7, work with microSD; samples also include USB for other models.Play video

Program communication and protection

  • Modbus RTU setup and troubleshootingModbus RTU Master Setup & Troubleshooting
    Setting the role of master and finding problems in serial communication Modbus RTU.Play video
  • Data exchange via Modbus TCPUsing Modbus TCP for OCS to OCS Communication
    Example of connecting OCS controllers and exchanging data over Ethernet.Play video
  • Protection of the created programCscape Security: Protecting your IP in the Horner OCS
    Protecting your program in Cscape, including OEM Lock.Play video

Choose the procedures according to the series, equipment and version Cscape of your device.

First project, starter setup and support

Setup for initial commissioning

We will select a suitable power supply, connections and any external I/O for this panel. The quotation will itemise the hardware and optional start-up support. Standard Cscape is free.

Help with your project

We arrange consultation, configuration, programming or training in Liberec for individuals and groups. We will confirm the scope of work, output, price and deadline in advance.

The price of the entire assembly and services is on request. The price of the panel itself remains in the offer above. We select sensors and controlled elements according to the actual task.

Deployment examples HORNER

X7 in weighing and dosing

Tomassis Engineering used HORNER X7 for weighing and dosing, recipes and batch data. Read the deployment example published on FOXON.

Read case study X7

Try and choose for your task

Send technology function, necessary signals and deadline. We will check the possibility of a loan or discuss a suitable product and the price of the necessary equipment.

Properties HORNER X7

In the menu above, you choose from two designs X7. It is mainly the type of outputs that decides; analog inputs and outputs are the same for both variants.

Design and types of signals

HE-X7A

12 digital inputs, 12 transistor outputs, 4 analog inputs and 2 analog outputs.

For tasks with transistor outputs; two support PWM to 65 kHz.

HE-X7R

12 digital inputs, 6 relay and 2 transistor/PWM outputs, 4 analog inputs and 2 analog outputs.

For tasks requiring relay contacts. Two transistor outputs support PWM to 10 kHz.

Control system and hardware versions

ProgrammingCscape; Advanced Ladder and languages IEC 61131-3
Program memory256 kB
Cycle of logic0,4 ms/kB
Display7″, 65 thousand colours, touch control
Resolution and brightness800 × 480 px; 300 cd/m²
ScreensUp to 250 screens; up to 100 objects on the screen
Storage mediummicroSD, max 32 GB, FAT32

Inputs and outputs

Digital inputs12; input voltage 12/24 V DC; 4 inputs can be used as HSC to 500 kHz
Outputs HE-X7A12 transistors; including 2 PWM to 65 kHz
Outputs HE-X7R6 relay + 2 transistor; PWM to 10 kHz
Analog inputs4; 0-20 mA, 4-20 mA or Pt100; 12 bits
Measurement Pt100-50 to +200 °C; connection according to the scheme of the selected model
Analog outputs2; 4-20 mA; 12 bits; max. load 500 Ω
Analog inputs support 0 - 20 mA , 4 - 20 mA or Pt100 (- 50 to + 200 °C); these are not inputs 0 - 10 V . The method of connection Pt100 and the use of terminals is different from the current measurement. The two analog outputs are 4 - 20 mA . The high-speed counters share four digital inputs and the PWM shares two transistor outputs. Check load limits, common terminals and wiring for A or R in the datasheet. Control the pump or motor via a power element suitable for the given load.

Ports and communication functions

Ethernet1× 10/100 Mb/s
Serial ports1× RS232 and 1× RS485; common connector MJ1/2
Serial communicationModbus RTU; additional protocols and licenses as configured
CAN1× RJ45; CsCAN, connecting the corresponding remote I/O
USB Mini-BProgramming; does not serve as USB host for flash drive
LicenseStandard Cscape free; we will verify additional communication and web functions according to requirements

Assembly and operating conditions

Power supply24 V DC ±20 %
Current consumption at full backlightTypically 190 mA at 24 V DC
Device dimensions (w x h x d)186,1 × 143,6 × 46,9 mm
Mounting cutout175 × 131,93 mm; tolerance ±0,5 mm
AssemblyInto the panel using four clips
Device weight590 g
Operating temperature-10 to +60 °C
Storage temperature-20 to +70 °C
Relative humidity5-95 %, no condensation

Contents of delivery and accessories

Panel in selected design and mounting clips. We will confirm the exact range of connectors and accessories for the supplied version. Choose the source, programming cable and sensors separately.

Source 24 V DC and programming cable USB Mini-B or Ethernet; separate items by assembly.

Accessories3