- PLC with HMI and I/O
- HORNER X10 PLC HMI controller with 10″ colour touchscreen, analog / digital inputs and outputs
HORNER X10 PLC HMI controller with 10″ colour touchscreen, analog / digital inputs and outputs - Type: 12x DI (24 VDC, 4x HSC, 500 kHz), 12x DO (24 VDC, 2x PWM, 65 kHz), 4x AI (0-20 mA, 4-20 mA, PT100 RTD, 12 bit), 2x AO (4-20 mA, 12 bit)
HORNER X10 combines PLC, 10,1″ color touch screen and built-in I/O for machinery and small technology. Cscape for PLC program and screens is free. FOXON will help with selection, first project and training.
More
Code: HE-X10A
HORNER X10 combines PLC, 10,1″ color touch screen and built-in I/O for machinery and small technology. Cscape for PLC program and screens is free. FOXON will help with selection, first project and training.
More
Code: HE-X10A
Options 2
| Type | Code | Availability | Price excl. VAT | |
|---|---|---|---|---|
| 12x DI (24 VDC, 4x HSC, 500 kHz), 12x DO (24 VDC, 2x PWM, 65 kHz), 4x AI (0-20 mA, 4-20 mA, PT100 RTD, 12 bit), 2x AO (4-20 mA, 12 bit) | HE-X10A | Delivery in 1-2 weeks |
1 127 EUR
|
|
| 12x DI (24 VDC, 4x HSC, 500 kHz), 2x DO (24 VDC, 2x PWM, 65 kHz), 6x DO relay (3 A), 4x AI (0-20 mA, 4-20 mA, PT100 RTD, 12 bit), 2x AO (4-20 mA, 12 bit) | HE-X10R | Delivery in 1-2 weeks |
1 127 EUR
|
PLC, control and I/O in one panel.
HORNER X10 connects PLC, 10,1″ color touch screen and built-in inputs and outputs. From one place you collect signals, control the machine or tool and change the technology settings. The larger screen will provide more space for controls, status messages and value overview.
Standard Cscape is free with each panel. You can create the PLC program and the HMI screens without a paid programming license. Additional features have their own license terms.

Verify X10 on your own task.
Free loan of selected products for 14 days is arranged individually according to availability. We will confirm the specific model, date and conditions in advance. FOXON will help with the selection and the first project.
Introducing X10
The Horner short product video introduces the X10 and its basic equipment. English.
Applications in small machines and systems
Pump switching according to time or event
Starting at a specified time, running for a set time or reacting to a level and other input signal. The operator sets the values and sees the pump status on the display.
Controlling a small machine or fixture
Starting the work cycle, continuity of individual steps and counting of pieces. The operator changes the length of the step or the number of repetitions on the panel.
Measurement and simple regulation
Display of pressure, temperature or other quantity and reaction to the set limit. The sensor type and signal range must match the selected panel inputs.
Local equipment monitoring
Input states, error messages and common settings on one display. You can prepare the range of screens and controls according to the specific device.
You create a function for your technology in Cscape. Select the necessary sensors and control elements according to the device.
Trial loan and training
Free loan by agreement
Free loan of selected products for 14 days is arranged individually according to availability. We will confirm the specific model, date and conditions in advance.
Training in Liberec
We train individuals and groups in our training room in Liberec. We will agree on the scope and date according to the experience of the participants and their tasks.
The original Horner Automation Europe video instructions are used for self-study. Translated titles and annotations explain their content, videos remain in English. Horner Europe video tutorials on YouTube
Selection of variant X10
In the menu above, you choose from two designs X10. It is mainly the type of outputs that decides; analog inputs and outputs are the same for both variants.
HE-X10A12 digital inputs, 12 transistor outputs, 4 analog inputs and 2 analog outputs.
For tasks with transistor outputs; two support PWM to 65 kHz.
HE-X10R12 digital inputs, 6 relay and 2 transistor/PWM outputs, 4 analog inputs and 2 analog outputs.
For tasks requiring relay contacts. Two transistor outputs support PWM to 65 kHz.
We will advise you on the selection of a suitable design and accessories according to the project.
Signal types and wiring limitations
Analog inputs support 0 - 20 mA , 4 - 20 mA or Pt100 (- 50 to + 200 °C); these are not inputs 0 - 10 V . The method of connection Pt100 and the use of terminals is different from the current measurement. The two analog outputs are 4 - 20 mA . The high-speed counters share four digital inputs and the PWM shares two transistor outputs. Check load limits, common terminals and wiring for A or R in the datasheet. Control the pump or motor via a power element suitable for the given load.
Technical parameters HORNER X10
| Display | 10,1″ color touch, 1024 × 600 px |
|---|---|
| Program memory | 256 kB |
| Built-in I/O | A: 12 DI / 12 DO / 4 AI / 2 AO; R: 12 DI / 6 relay + 2 DO / 4 AI / 2 AO |
| Analog signals | AI: 0-20 mA, 4-20 mA or Pt100; AO: 4-20 mA |
| Connection | Ethernet 10/100 Mb/s, RS232, RS485, CAN, USB Mini-B, microSD |
| Power supply | 10-30 V DC; commonly 24 V DC |
| Operating temperature | -10 to +60 °C |
You can find detailed information in the tab Features.
Connection and operation
X10 has Ethernet 10/100 Mb/s, RS232 and RS485 in common connector MJ1/2 and CAN with CsCAN protocol for corresponding expansion I/O. USB Mini-B is for programming; microSD to store and transfer data.
You create the control program and screens in Cscape. Choose protocols and remote access according to the specific feature and its license; Do not consider CANopen, BACnet and extended WebMI as an automatic part of free programming. We will verify the necessary combination before ordering.

Equipment and cost of first launch
| Panel HORNER X10 | Current price in the selection of variants above |
|---|---|
| Standard Cscape | 0 CZK - program PLC and screens HMI |
| Power supply and connection | Source 24 V DC and programming cable USB Mini-B or Ethernet; separate items by assembly. |
| Sensors and controls | According to the signals and loads of your job |
| Training, design and assembly | Pricing according to the agreed scope |
The price of the panel is not the price of the entire automation. In the offer, we will discuss the necessary equipment and the possible work of technicians. We select the source, cables and other accessories according to the assembly.
Contents of the standard package
Panel in selected design and mounting clips. We will confirm the exact range of connectors and accessories for the supplied version. Choose the source, programming cable and sensors separately.
First project in Cscape
Download Cscape from Horner. You need a manufacturer account to download. The video shows PC connection, hardware configuration, simple program and HMI Micro OCS series screen.
Your first test task
When first verifying, start with one simple function. For example, an output that switches on for a set time after pressing a button or changing the input signal.
- Set the switching time on the display and show the input and output status.
- Handle the trigger condition and timer in the program.
- On the test load, verify switching on, switching off after a time has elapsed and changing the settings on the display.
Photo gallery and connection
Click to open a separate image in a larger view.
Frequently asked questions
Do I need separate PLC or HMI?
X10 includes PLC, color touch screen and built-in I/O. You do not need separate PLC and HMI for the same task. You choose the extension according to the signals you need.
What is free and what is charged separately?
Standard Cscape is free with each panel. You can create the PLC program and the HMI screens without a paid programming license. Additional features have their own license terms. Free loan of selected products for 14 days is arranged individually according to availability. We will confirm the specific model, date and conditions in advance. Accessories, training and the work of technicians will be priced according to the scope.
Do I connect sensor 0-10 V?
HE-X10A and HE-X10R have current or Pt100 analog inputs. For sensor 0 - 10 V a corresponding other I/O or design modification is needed. Send the sensor type and we will choose the right solution.
How can I check trial loan availability?
Click Arrange a trial loan and describe your application. We will check a suitable loan model, availability, dates and conditions. Trial loans of selected products are arranged individually.
Can you help with the first project?
We advise on the selection of equipment and offer training in Liberec for individuals and groups. If necessary, we will prepare the project design and assembly with our own technicians.
Why buy from FOXON
Distributor HORNER
We supply new HORNER products with warranty and will help you choose the right equipment and accessories.
Selection according to your project
We will discuss technology function, signals and communication. We will compare the entry with the HORNER options and select a suitable product.
Technical support and training
We advise on the use of the equipment and train individuals and groups. For self-study, we recommend the manufacturer's instructions.
Solution design and assembly
If necessary, we will design a solution, prepare a project and install the equipment with our own technicians. We will agree on the scope of work according to the technology.
Video tutorials by topic
First project, starter setup and support
Setup for initial commissioning
We will select a suitable power supply, connections and any external I/O for this panel. The quotation will itemise the hardware and optional start-up support. Standard Cscape is free.
Help with your project
We arrange consultation, configuration, programming or training in Liberec for individuals and groups. We will confirm the scope of work, output, price and deadline in advance.
Deployment examples HORNER
View specific deployments of HORNER X4 and X7 at machine manufacturers. The model used and the implementer are listed in the relevant study.
Try and choose for your task
Send technology function, necessary signals and deadline. We will check the possibility of a loan or discuss a suitable product and the price of the necessary equipment.
Downloads and initial setup
Documents and videos are in English. Select the current datasheet according to the entire order code. Some downloads on the manufacturer's website require registration and login.
Software and first steps
Cscape - environment for both PLC and HMI
Standard Cscape is free with each panel. You can create the PLC program and the HMI screens without a paid programming license. Additional features have their own license terms. You need a manufacturer account to download.
Open the materialFirst project in Cscape
The video shows PC connection, hardware configuration, simple program and HMI Micro OCS series screen.
Open the materialHorner Europe video tutorial library
Additional procedures for programming, screens and communication. Choose according to the functions of your panel.
Open the materialProduct selection and range overview
X10 - overview of product and use
Brief brochure for the first acquaintance. Use the current datasheet for connection.
Open the materialConnection and commissioning
X10 A/R - electrical parameters and connections
Current datasheet for HE-X10A and HE-X10R. Signal types, output limits, terminals, ports and dimensional drawing.
Open the materialX10 - quick connection and assembly
A quick guide for the first connection and installation. Check the datasheet for electrical limits.
Open the materialX10 A/R - configuration and operation
User manual: system menu, configuration, communication, work with data and I/O.
Open the materialDrawings and firmware
X10 - electrical drawings
Basics for circuit design; distinguish the A and R versions.
Open the materialX10 - mechanical drawings
Dimensional documents for installation in the switchboard. Please verify the specific model before production.
Open the materialFirmware and Release Notes
Select the exact model and read the update conditions. Back up the project and settings before changing the firmware.
Open the materialProperties HORNER X10
In the menu above, you choose from two designs X10. It is mainly the type of outputs that decides; analog inputs and outputs are the same for both variants.
Design and types of signals
HE-X10A12 digital inputs, 12 transistor outputs, 4 analog inputs and 2 analog outputs.
For tasks with transistor outputs; two support PWM to 65 kHz.
HE-X10R12 digital inputs, 6 relay and 2 transistor/PWM outputs, 4 analog inputs and 2 analog outputs.
For tasks requiring relay contacts. Two transistor outputs support PWM to 65 kHz.
Control system and hardware versions
| Programming | Cscape; Advanced Ladder and languages IEC 61131-3 |
|---|---|
| Program memory | 256 kB |
| Cycle of logic | 0,4 ms/kB |
| Display | 10,1″, 65 thousand colours, touch control |
| Resolution and brightness | 1024 × 600 px; 300 cd/m² |
| Screens | Up to 250 screens; up to 100 objects on the screen |
| Storage medium | microSD, max 32 GB, FAT32 |
Inputs and outputs
| Digital inputs | 12; input voltage 12/24 V DC; 4 inputs can be used as HSC to 500 kHz |
|---|---|
| Outputs HE-X10A | 12 transistors; including 2 PWM to 65 kHz |
| Outputs HE-X10R | 6 relay + 2 transistor; PWM to 65 kHz |
| Analog inputs | 4; 0-20 mA, 4-20 mA or Pt100; 12 bits |
| Measurement Pt100 | -50 to +200 °C; connection according to the scheme of the selected model |
| Analog outputs | 2; 4-20 mA; 12 bits; max. load 500 Ω |
Ports and communication functions
| Ethernet | 1× 10/100 Mb/s |
|---|---|
| Serial ports | 1× RS232 and 1× RS485; common connector MJ1/2 |
| Serial communication | Modbus RTU; additional protocols and licenses as configured |
| CAN | 1× RJ45; CsCAN, connecting the corresponding remote I/O |
| USB Mini-B | Programming; does not serve as USB host for flash drive |
| License | Standard Cscape free; we will verify additional communication and web functions according to requirements |
Assembly and operating conditions
| Power supply | 10-30 V DC; commonly 24 V DC |
|---|---|
| Current consumption at full backlight | HE-X10A : typically 305 mA ; HE-X10R : typically 295 mA at 24 V DC |
| Device dimensions (w x h x d) | 265,2 × 167,8 × 55,1 mm |
| Mounting cutout | 175 × 131,9 mm; tolerance ±1 mm |
| Assembly | Into the panel using four clips |
| Device weight | 1 105,6 g |
| Operating temperature | -10 to +60 °C |
| Storage temperature | -20 to +70 °C |
| Relative humidity | 5-95 %, no condensation |
Contents of delivery and accessories
Panel in selected design and mounting clips. We will confirm the exact range of connectors and accessories for the supplied version. Choose the source, programming cable and sensors separately.
Source 24 V DC and programming cable USB Mini-B or Ethernet; separate items by assembly.

VIDEO: Tips and tricks for setting up HORNER PLCs with display, inputs and outputs
HORNER PLCs combine machine control, operator display and inputs/outputs in one device. If you need a compact solution for a smaller machine, part of a production line, a test station or modernization of older equipment, you do not have to source and combine a separate PLC, HMI panel and I/O modules.
The manufacturer’s training videos show how to connect the panel, work in Cscape, set up communication, use WebMI and work with basic inputs and outputs. They are especially useful during initial commissioning, so you do not have to figure everything out by trial and error.

Review: Horner Canvas Series PLC with Integrated HMI – Part 1: PLC
Horner PLCs with integrated HMI are new not only to our e-shop, but also to our market. We asked respected industrial automation specialist Jaroslav Blažek (blaja.cz) to explore all the functions and user-friendliness of these devices. You can find out whether he was satisfied and what it was like working with the Horner units in his review.

Review: How CANbus OCS-I/O Peripherals Work with the Horner Canvas 4 PLC/HMI
External I/O peripherals can be connected to Horner PLCs with HMI—and are often required. Learn how Jaroslav Blažek (blaja.cz) tested connecting an OCS-I/O module with digital and analog inputs/outputs to a Canvas 4 PLC/HMI via the CANbus.

Review: Cscape Software for Horner PLCs with Integrated HMI
For efficient work with Horner panels (PLCs with integrated HMI), you need a reliable and intuitive programming tool. The Cscape software allows configuration of both the PLC and the integrated HMI within a single environment—and it’s free. Once again, we asked specialist Jaroslav Blažek (blaja.cz) to take a closer look at the software. You can find out how the installation and registration went in his review.

Review: Horner Canvas Series PLC with Integrated HMI – Part 2: HMI and Remote Monitoring
Horner PLCs with integrated HMI have not been part of our product range for long, but they are already attracting well-deserved attention. We asked industrial automation expert Jaroslav Blažek (blaja.cz) to take a closer look at them — especially in terms of functionality, intuitive operation, and practical deployment options. Find out how these Horner devices performed and what he has to say about them in the following review.

New on the Market: Touchscreen PLC with Integrated HMI and I/Os from Horner Automation
Are you looking for a compact, powerful and easy-to-integrate solution for machine control or upgrading existing technology? We are pleased to introduce a new addition to our product range: panels from Horner Automation. Their PLCs, which feature an integrated HMI with a touchscreen display and inputs/outputs, are ideal for designers of new machines as well as engineers looking to innovate their companies' production.

Case Study: How the Horner X7 Control Panel Automated Weighing and Dosing
A new fully automated dosing and weighing machine is controlled by a Horner X7 PLC with integrated HMI and I/Os. In this setup, the industrial panel manages recipes, temperature control, and precise weighing of ingredients. At the same time, it collects batch data, eliminates human errors, and ensures consistent food quality. What does it look like in practice?
Highlighted items are mandatory.