HORNER XL10 PRIME combines PLC and 10,4″ color touch screen and physical function buttons. Six designs allow you to choose the necessary I/O; HEXP505C100 is without built-in inputs and outputs. Cscape for PLC program and screens is free. FOXON will help with selection, first project and training.

Arrange a trial loan


More

Code: HEXP505C100

2 180 EUR excl. VAT (2 637,80 EUR Incl. VAT)
Variant does not exist
Delivery in 1-2 weeks
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote

Horner Automation

HORNER XL10 PRIME combines PLC and 10,4″ color touch screen and physical function buttons. Six designs allow you to choose the necessary I/O; HEXP505C100 is without built-in inputs and outputs. Cscape for PLC program and screens is free. FOXON will help with selection, first project and training.

Arrange a trial loan


More

Code: HEXP505C100

Options 6

Type Code Availability Price excl. VAT
No built-in I/O HEXP505C100 Delivery in 1-2 weeks
2 180 EUR
12x DI (24 VDC, 4x HSC, 1 MHz), 6x DO relay (3 A), 4x AI (0-10 V, 0-20 mA, 4-20 mA, 12 bit) HEXP505C112 Delivery in 1-2 weeks
2 323 EUR
12x DI (24 VDC, 4x HSC, 500 kHz), 12x DO (24 VDC, 2x PWM, 10 kHz), 2x AI (0-10 V, 0-20 mA, 4-20 mA, 12 bit) HEXP505C113 Delivery in 1-2 weeks
2 443 EUR
24x DI (24 VDC, 4x HSC, 500 kHz), 16x DO (24 VDC, 2x PWM, 10 kHz), 2x AI (0-10 V, 0-20 mA, 4-20 mA, 12 bit) HEXP505C114 Delivery in 1-2 weeks
2 486 EUR
12x DI (24 VDC, 4x HSC, 500 kHz), 12x DO (24 VDC, 2x PWM, 10 kHz), 2x AI (0-10 V, 100 mV, 0-20 mA, 4-20 mA, RTD, THM, 14/16 bit), 2x AO (0-10 V, 0-20 mA, 4-20 mA, 12 bit) HEXP505C115 Delivery in 1-2 weeks
2 533 EUR
12x DI (24 VDC, 4x HSC, 500 kHz), 12x DO (24 VDC, 2x PWM, 10 kHz), 6x AI (0-10 V, 60 mV, 0-20 mA, 4-20 mA, RTD, THM, 17 bit), 4x AO (0-10 V, 0-20 mA, 4-20 mA, 12 bit) HEXP505C116 Delivery in 1-2 weeks
2 669 EUR
HORNER XL10 PRIME · PLC + HMI · I/O according to variant

PLC and control in one panel. I/O according to your task.

HORNER XL10 PRIME combines PLC and 10,4″ color touch screen and physical function buttons. You control a small machine or fixture and monitor operating values ​​from one place. You can choose from six designs: from the model without built-in I/O to variants with digital, analog and temperature inputs.

Standard Cscape for both PLC program and HMI screens is free with each panel. You do not buy a programming license. Optional communication and web features have their own license and firmware terms.

HORNER XL10 PRIME - device photo

Verify XL10 PRIME on your own task.
Free loan of selected products for 14 days is arranged individually according to availability. We will confirm the specific model, date and conditions in advance. FOXON will help with the selection and the first project.

10,4″ color touch640 × 480 px; function buttons
Six designs I/OFrom no built-in I/O to up to 42 built-in points
2 MB program memoryCscape for both logic and screens

Introducing the XL PRIME series

The original video Horner presents the XL series PRIME, which also includes XL10 PRIME. It shows the common concept of PLC and HMI; choose a specific display, connectors and I/O according to the parameters of this model. English.

Watch the introduction on YouTube

Applications in small machines and systems

Pump switching according to time or event

Starting at a specified time, running for a set time or reacting to a level and other input signal. The operator sets the values ​​and sees the pump status on the display.

Controlling a small machine or fixture

Starting the work cycle, continuity of individual steps and counting of pieces. The operator changes the length of the step or the number of repetitions on the panel.

Measurement and simple regulation

Display of pressure, temperature or other quantity and reaction to the set limit. The sensor type and signal range must match the selected built-in or extension I/O.

Local equipment monitoring

Input states, error messages and common settings on one display. You can prepare the range of screens and controls according to the specific device.

You create a function for your technology in Cscape. Select the necessary sensors and control elements according to the device.

Trial loan and training

Free loan by agreement

Free loan of selected products for 14 days is arranged individually according to availability. We will confirm the specific model, date and conditions in advance.

Training in Liberec

We train individuals and groups in our training room in Liberec. We will agree on the scope and date according to the experience of the participants and their tasks.

The original Horner Automation Europe video instructions are used for self-study. Translated titles and annotations explain their content, videos remain in English. Horner Europe video tutorials on YouTube

Selection of variant XL10 PRIME

Select the design according to the list of signals. The HEXP505C100 is the 0 model without the built-in I/O. Codes HEXP505C112 to HEXP505C116 indicate models 2 to 6 with different combinations of inputs and outputs. Prices and availability are listed above.

HEXP505C100

No built-in inputs and outputs.

For control over a communication interface or with suitable expansion I/O.

HEXP505C112

12 digital inputs, 6 relay outputs and 4 analog inputs (12 bits).

For tasks with relay contacts and measuring 0-10 V or current signals.

HEXP505C113

12 digital inputs, 12 transistor outputs and 2 analog inputs (12 bits).

For control with transistor outputs and two analog signals.

HEXP505C114

24 digital inputs, 16 transistor outputs and 2 analog inputs (12 bits).

For jobs with more digital signals; total 42 points I/O.

HEXP505C115

12 digital inputs, 12 transistor outputs, 2 universal analog inputs and 2 analog outputs.

For measurements including Pt100 and thermocouples and for analog control.

HEXP505C116

12 digital inputs, 12 transistor outputs, 6 universal analog inputs and 4 analog outputs.

For multiple analog and temperature signals as well as output values.

We will advise you on the selection of a suitable design and accessories according to the project.

Signal types and wiring limitations

The numbers and types of I/O relate to a specific order code. HEXP505C100 does not have a built-in I/O. 2, 3 and 4 models support analog inputs 0-10 V, 0-20 mA and 4-20 mA. Choose 5 or 6 for direct measurement of Pt100 and thermocouples. The analog channel mode must match the jumpers and configuration of the Cscape. The voltage and current terminals of the same analog output are not two independent channels. Quick features share selected digital channels. Check the connection, signal combination and current limits in the datasheet of the exact design.

Technical parameters HORNER XL10 PRIME

Display and control10,4″ color touch, 640 × 480 px; touch screen and physical function buttons
Program memory2 MB
Built-in I/OAccording to the variant: none to 42 points
Connection1× Ethernet, RS232, RS485, 1× CAN, USB Mini-B, USB-A, microSD
ProgrammingStandard Cscape free; logic and screens in one project
Power supply10-30 V DC for standard design
Operating temperature-10 to +60 °C for standard design

You can find detailed information in the tab Features.

Connection and operation

XL10 PRIME has 1 ethernet port 10/100 Mb/s, RS232 and RS485 in a common connector MJ1/2, another serial port MJ3 (RS232 or RS485) and 1 port CAN. For data exchange you use for example Modbus TCP or Modbus RTU depending on the project settings. USB-A and microSD are for working with data; USB Mini-B to connect to a PC.

You can create logic and standard HMI screens in the free Cscape. WebMI, MQTT, J1939 and other optional features have their own license and firmware terms. We will verify the required communication and its price according to the project.

HORNER XL10 PRIME - photo of the device from the front
Photograph of the device from the front

Equipment and cost of first launch

Panel HORNER XL10 PRIMECurrent price in the selection of variants above
Standard Cscape0 CZK - program PLC and screens HMI
Power supply and connection24 V DC power supply and programming link USB Mini-B or Ethernet; separate items depending on the setup. For HEXP505C100, add the necessary external I/O if the job requires them.
Sensors and controlsAccording to the signals and loads of your job
Training, design and assemblyPricing according to the agreed scope

The price of the panel is not the price of the entire automation. In the offer, we will discuss the necessary equipment and the possible work of technicians. We select the source, cables and other accessories according to the assembly.

Contents of the standard package

Panel in the ordered version. We will confirm the range of supplied mounting elements and connectors for the selected I/O model. Select the source, programming cable, memory medium, sensors and external I/O according to the assembly. The HEXP505C100 model does not have a built-in I/O.

First project in Cscape

Download Cscape from Horner. You need a manufacturer account to download Cscape. The video shows the PC connection, simple logic and the first screen on the Micro OCS panel. When working with XL10 PRIME, select your exact model and the corresponding I/O in configuration.

Open YouTube tutorial

Your first test task

When first verifying, start with one simple function. For example, an output that switches on for a set time after pressing a button or changing the input signal.

  • Set the switching time on the display and show the input and output status.
  • Handle the trigger condition and timer in the program.
  • On the test load, verify switching on, switching off after a time has elapsed and changing the settings on the display.

Cscape training exercises from Horner

Photo gallery and connection

Click to open a separate image in a larger view.

Frequently asked questions

Do I need separate PLC or HMI?

XL10 PRIME contains both PLC and touch HMI. You do not need separate PLC and HMI for the same task. Built-in I/O depends on the code: HEXP505C100 does not have them, models 2 to 6 have different combinations of signals.

What is free and what is charged separately?

Standard Cscape is free with each panel. You can create the PLC program and the HMI screens without a paid programming license. Additional features have their own license terms. Free loan of selected products for 14 days is arranged individually according to availability. We will confirm the specific model, date and conditions in advance. Accessories, training and the work of technicians will be priced according to the scope.

Which design to choose for Pt100 or thermocouple?

For direct temperature measurement, choose universal analog inputs of model 5 (HEXP505C115) or model 6 (HEXP505C116). We will compare the sensor type, number of channels and connection with the datasheet of the selected design.

How to choose the display size?

XL10 PRIME offers a 10,4″ display with a 640 × 480 px resolution. Place the necessary buttons, values ​​and alarms in the screen design. We will compare the readability, space in the cabinet and I/O with other Horner panels.

Can you assess migration from an older panel?

Send the full order number of the original device, version Cscape and available project. We will verify the I/O configuration, assembly, communication and the necessary modifications to the project.

How can I check trial loan availability?

Click Arrange a trial loan and describe your application. We will check a suitable loan model, availability, dates and conditions. Trial loans of selected products are arranged individually.

Can you help with the first project?

We advise on the selection of equipment and offer training in Liberec for individuals and groups. If necessary, we will prepare the project design and assembly with our own technicians.

Why buy from FOXON

Distributor HORNER

We supply new HORNER products with warranty and will help you choose the right equipment and accessories.

Selection according to your project

We will discuss technology function, signals and communication. We will compare the entry with the HORNER options and select a suitable product.

Technical support and training

We advise on the use of the equipment and train individuals and groups. For self-study, we recommend the manufacturer's instructions.

Solution design and assembly

If necessary, we will design a solution, prepare a project and install the equipment with our own technicians. We will agree on the scope of work according to the technology.

More than 3 500customers
We deliver tomore than 100 countries of the world
Express delivery?We will check it, contact us immediately.

Video tutorials by topic

The videos were prepared by Horner. Translated titles and summaries explain their content. The videos are in English. General Cscape tutorials also use other panels; adapt the hardware configuration, I/O and licensed features to XL10 PRIME.

First project and programming

  • First project with Micro OCSGet Started with Cscape 10 and Micro OCS
    Panel connection to PC, hardware configuration, simple program and first screen.Play video
  • Orientation in the Cscape 10 projectThe Cscape 10 Project Navigator
    Working with the project navigator and overview of its parts in Cscape 10.Play video
  • Programming in IEC 61131 languagesIEC 61131 Logic Programming in Cscape 10
    Introducing IEC control logic editor capabilities in Cscape 10.Play video
  • Uploading the program to the panelCscape 10 Program Downloads
    Program transfer options and procedures in Cscape 10.Play video

Display, screens and alarms

  • Creating and editing screensCscape 10 Graphics Editing
    Editing graphics and working with the screen editor in Cscape 10.Play video
  • Screen arrangement HMIScreen Organisation in Cscape
    Organization of multiple user screens in the Cscape project.Play video
  • Setting and using alarmsProgramming and using Alarms on the OCS
    Programming and use of fault and other alarm messages in OCS.Play video

Inputs, outputs and control

  • Signal conversion to pressure, temperature or levelAnalog IO Scaling in Cscape
    Conversion of analog sensor values to physical units in the program.Play video
  • Conditions by value, time and dateCompare Functions (Including LIMIT & Time/Date) in Cscape
    Comparison function including limits and working with time and date.Play video
  • Initial values of machine parametersUsing Setpoints with Horner Controllers
    Setting and transferring initial values of variables; the procedure depends on the selected language.Play video

Data logging, graphs and files

  • Setting up the recording of operating dataProgramming and using Datalogging on the OCS
    The basics of programming and using datalogging in the OCS control unit.Play video
  • Displaying trends in a graphUsing Trends on the Horner OCS
    Use of trends to display the evolution of monitored values.Play video
  • Management of recorded data filesTake Control of Horner Datalogging Files
    Working with files that are created when data is recorded on a storage medium.Play video
  • Reading and writing CSV, XML and TXT filesUsing Removable Media Functions in Cscape Part 2
    Creating and using custom data files. For XL10 PRIME, use a supported storage medium; samples also include USB for other models.Play video

Program communication and protection

  • Modbus RTU setup and troubleshootingModbus RTU Master Setup & Troubleshooting
    Setting the role of master and finding problems in serial communication Modbus RTU.Play video
  • Data exchange via Modbus TCPUsing Modbus TCP for OCS to OCS Communication
    Example of connecting OCS controllers and exchanging data over Ethernet.Play video
  • Protection of the created programCscape Security: Protecting your IP in the Horner OCS
    Protecting your program in Cscape, including OEM Lock.Play video

Product series selection and communication

  • Comparison of XL PRIME and CANVASXL Prime vs Canvas – Which Should I Use?
    Comparison of equipment, graphics, communication and license terms of both series.Play video

Choose the procedures according to the series, equipment and version Cscape of your device.

First project, starter setup and support

Setup for initial commissioning

We will select a suitable power supply, connections and any external I/O for this panel. The quotation will itemise the hardware and optional start-up support. Standard Cscape is free.

Help with your project

We arrange consultation, configuration, programming or training in Liberec for individuals and groups. We will confirm the scope of work, output, price and deadline in advance.

The price of the entire assembly and services is on request. The price of the panel itself remains in the offer above. We select sensors and controlled elements according to the actual task.

Deployment examples HORNER

View specific deployments of HORNER X4 and X7 at machine manufacturers. The model used and the implementer are listed in the relevant study.

Try and choose for your task

Send technology function, necessary signals and deadline. We will check the possibility of a loan or discuss a suitable product and the price of the necessary equipment.

Properties HORNER XL10 PRIME

Select the design according to the list of signals. The HEXP505C100 is the 0 model without the built-in I/O. Codes HEXP505C112 to HEXP505C116 indicate models 2 to 6 with different combinations of inputs and outputs. Prices and availability are listed above.

Design and types of signals

HEXP505C100

No built-in inputs and outputs.

For control over a communication interface or with suitable expansion I/O.

HEXP505C112

12 digital inputs, 6 relay outputs and 4 analog inputs (12 bits).

For tasks with relay contacts and measuring 0-10 V or current signals.

HEXP505C113

12 digital inputs, 12 transistor outputs and 2 analog inputs (12 bits).

For control with transistor outputs and two analog signals.

HEXP505C114

24 digital inputs, 16 transistor outputs and 2 analog inputs (12 bits).

For jobs with more digital signals; total 42 points I/O.

HEXP505C115

12 digital inputs, 12 transistor outputs, 2 universal analog inputs and 2 analog outputs.

For measurements including Pt100 and thermocouples and for analog control.

HEXP505C116

12 digital inputs, 12 transistor outputs, 6 universal analog inputs and 4 analog outputs.

For multiple analog and temperature signals as well as output values.

Control system and hardware versions

ProgrammingCscape; Advanced Ladder and languages IEC 61131-3, extended modes by license
Program memory2 MB
Cycle of logic0,02 ms/kB
Display10,4″ VGA TFT
Resolution640 × 480 px
Brightness550 cd/m² typically
ControlTouch screen and physical function buttons
ScreensUp to 1 023 screens; up to 1 023 objects on the screen
Storage mediamicroSD up to 32 GB, FAT32; supported USB media via USB-A
Graphics memory27 MB

Inputs and outputs

HEXP505C100 - model 0Without built-in I/O
HEXP505C112 - model 212 DI / 6 relays / 4 AI (12 bits)
HEXP505C113 - model 312 DI / 12 DO / 2 AI (12 bits)
HEXP505C114 - model 424 DI / 16 DO / 2 AI (12 bits)
Analog inputs of models 2, 3 and 40-10 V, 0-20 mA, 4-20 mA
HEXP505C115 - model 512 DI / 12 DO / 2 universal AI / 2 AO
Analog signals of the model 5AI: 0-10 V, 0-20 mA, 4-20 mA, mV, Pt100 and J/K/N/T/E/R/S/B thermocouples; 14 bits for V/mA/mV, 16 bits for temperature. AO: 0-10 V or 0-20 mA; 12 bits.
HEXP505C116 - model 612 DI / 12 DO / 6 universal AI / 4 AO
Analog signals of the model 6AI: 0-10 V, 0-20 mA, 4-20 mA, mV, Pt100/Pt1000 and ungrounded thermocouples J/K/N/T/E/R/S/B; 17 bits. AO: 0-10 V, 0-20 mA, 4-20 mA; 12 bits.
The numbers and types of I/O relate to a specific order code. HEXP505C100 does not have a built-in I/O. 2, 3 and 4 models support analog inputs 0-10 V, 0-20 mA and 4-20 mA. Choose 5 or 6 for direct measurement of Pt100 and thermocouples. The analog channel mode must match the jumpers and configuration of the Cscape. The voltage and current terminals of the same analog output are not two independent channels. Quick features share selected digital channels. Check the connection, signal combination and current limits in the datasheet of the exact design.

Ports and communication functions

Ethernet1× 10/100 Mb/s; for example Modbus TCP, FTP, SMTP and ASCII
Serial ports1× RS232 and 1× RS485 on MJ1/2; an additional 1× RS232 or 1× RS485 on MJ3
CAN1×; specific protocol and firmware according to configuration
USB Mini-BPC connection for programming and data access
USB-AUSB host for supported devices and storage media
Expanding I/OSelection according to signals, bus and project configuration
License and Remote AccessStandard Cscape Free; We will verify WebMI, MQTT and other optional features according to requirements and license

Assembly and operating conditions

Standard design power supply10-30 V DC
Front dimensions303,3 × 230,6 mm; depth according to dimensional drawing and I/O design
Assembly288,5 × 216 mm; tolerance ±0,1 mm
Operating temperature of the standard design-10 to +60 °C
Storage temperature-20 to +60 °C
Relative humidity5-95 %, no condensation

Contents of delivery and accessories

Panel in the ordered version. We will confirm the range of supplied mounting elements and connectors for the selected I/O model. Select the source, programming cable, memory medium, sensors and external I/O according to the assembly. The HEXP505C100 model does not have a built-in I/O.

24 V DC power supply and programming link USB Mini-B or Ethernet; separate items depending on the setup. For HEXP505C100, add the necessary external I/O if the job requires them.

Accessories3