BACnet – license for Horner PLC HMI controllers X4, X7 and X10

BACnet – license for Horner PLC HMI controllers X4, X7 and X10
BACnet – license for Horner PLC HMI controllers X4, X7 and X10

BACnet – license for Horner PLC HMI controllers X4, X7 and X10


Horner Automation

Perpetual BACnet IP and MS/TP licence for 1 supported HORNER panel, for example Micro X4, X7 or X10. Exposes operating data to a building management system. We will verify the model, firmware and required interface.

More

Code: HE-VFB1-01

90 EUR excl. VAT (108,90 EUR Incl. VAT)
Inquire product
pcs

Rezervace termínu

Get a quote

Horner Automation

Perpetual BACnet IP and MS/TP licence for 1 supported HORNER panel, for example Micro X4, X7 or X10. Exposes operating data to a building management system. We will verify the model, firmware and required interface.

More

Code: HE-VFB1-01

HORNER BACnet IP and MS/TP

Make data from a small system available to the building management system.

The BACnet IP and MS/TP license will extend the supported HORNER panel with communication used in building automation. You make operational values, statuses and selected writable parameters available to the superior BMS system. Local control and operation of the technology will continue to be provided by the panel.

Optional extension for Micro X4, X7 and X10. BACnet is standard included in XL Prime, CANVAS and CPU300. We will verify the support of your model before purchase.

HORNER BACnet IP and MS/TP - original manufacturer's material

Send the model of the panel and the description of the desired function.
We will check whether the function is already part of the device, what license you need and what will need to be set.

BACnet/IPCommunication over Ethernet
BACnet MS/TPRS-485 serial communication
1 control unitPerpetual License HE-VFB1-01

Setting BACnet/IP in practice

Configuring the BACnet/IP server and making panel data available.

Open the video on YouTube

Use of BACnet in buildings

Transfer of temperatures and states to the BMS

The panel makes the values it measures or processes locally available to the superior building system.

Pump supervision

You transmit to the building system the running status, fault or hours of operation of the pump controlled by the panel.

Small ventilation system

You prepare local regulation and operation in HORNER and make the selected data available via BACnet.

Changing selected parameters

For enabled writable objects, you set the transfer of values from the BMS. You define the rights and behavior of the application in the project.

License selection and compatibility

Choose BACnet/IP over Ethernet or BACnet MS/TP over RS-485 according to the supervisory system and available port. The voucher includes both variants; actual use depends on the device and configuration.

Order codeHE-VFB1-01
License unit1 license for 1 controller HORNER; permanent activation by voucher.
Micro X4, X7 and X10BACnet is an optional license. Verify the model, firmware and available port.
CPU200 and CPU250BACnet is an optional licence; we will verify the required interface and scope for the specific configuration.
XL Prime, CANVAS and CPU300BACnet IP and MS/TP are standard functions.
XLEe and XLTeBACnet/IP is included by default. Do not infer MS/TP support from this.
Standard CscapeFree. This item is a separately paid feature extension.
Price and work of techniciansThe current price of the license is in the menu above. We will price configuration, training and the project according to the agreed scope.
The panel in the described use makes the BACnet objects available as a server. Automatic search and control of any foreign BACnet devices is not part of this offer.

Choice of communication interface

BACnet/IP

Suitable when connecting to a BMS Ethernet network. Network settings and device identification must be unified.

BACnet MS/TP

Suitable for RS-485 serial network. The project must address addresses, speed and correct bus wiring.

Data objects

Select the values and states the supervisory system should read and the parameters it is permitted to write.

Verification of communication before assembly

The bench test will facilitate the handover between the small technology manufacturer and the building system supplier. Below you will find the manufacturer's video dedicated to testing the BACnet before installation.

  1. Agree with the BMS supplier the variant BACnet, the list of objects and the required access.
  2. Verify panel, license, firmware and port for selected communication method.
  3. In Cscape prepare value mapping and device identification.
  4. Before installation, test readings, allowed writes, and response to loss of communication.

License content and project documents

Part of this itemPerpetual license BACnet IP and MS/TP for one supported device.
Necessary equipmentPanel or control unit HORNER with function support and corresponding interface.
Documents from BMS supplierRequired network variant, object list, read and write method and device identification.
SeparatelyCables, panel, superior BMS system and configuration or programming according to agreement.

Training and support for the first project

Training in Liberec

We train individuals and groups in our training room in Liberec. We will agree on the scope and date according to the experience of the participants and their tasks.

Self-study

The original Horner Automation Europe video instructions are used for self-study. Translated titles and annotations explain their content, videos remain in English. Video Tutorials Horner Europe.

We offer training in Liberec for individuals and groups. We will agree on the scope and price according to the project; you can also start with a self-study from the manufacturer's videos below.

BACnet verification before assembly

Communication testing procedure before deployment at the customer.

Open the video on YouTube

Original material HORNER

Click to open the original manufacturer's material in a larger view.

Frequently asked questions

Do I need special licenses for IP and MS/TP?

Voucher HE-VFB1-01 includes both BACnet IP and BACnet MS/TP for one device. We will verify the use of a specific interface and possible concurrence according to the panel and firmware.

Is a license also required for XL Prime?

For XL Prime, BACnet IP and MS/TP are included by default. Therefore, first verify the existing functions of the panel.

Does the panel automatically find all BACnet units?

This description refers to making panel data available as a BACnet server. The requirement to communicate with other devices must be assessed separately.

Is the older manual a one-size-fits-all installation procedure?

It is not. The manual contains procedures for older generations and versions. Choose the firmware and configuration for the current panel according to the specific model; don't automatically copy older packages.

Is standard Cscape paid?

The Cscape standard programming software is free. You buy a license that expands a specific function of the supported device, or you order our help with the project separately.

Can you help with the activation and the first project?

Yes. We will verify the model and license, advise on settings and offer training in Liberec. According to the agreement, we will also design the project and ensure assembly with our own technicians. We will confirm the scope and price of the services in the offer.

Why buy from FOXON

Distributor HORNER

We are a distributor of HORNER. We deliver new licenses and devices with warranty, advise on selection and provide technical support.

Selection according to your project

We will discuss technology function, signals and communication. We will compare the entry with the HORNER options and select a suitable product.

Technical support and training

We advise on the use of the equipment and train individuals and groups. For self-study, we recommend the manufacturer's instructions.

Solution design and assembly

If necessary, we will design a solution, prepare a project and install the equipment with our own technicians. We will agree on the scope of work according to the technology.

More than 3 500customers
We deliver tomore than 100 countries of the world
Express delivery?We will check it, contact us immediately.

Video tutorials by topic

The videos are from the producer HORNER and are in English. Translated headings make it easier to choose a topic. The samples use different panels and versions of Cscape; they are not a confirmation of compatibility for every model.

  • Overview of BACnet/IP and MS/TPBACnet MS/TP & BACnet IP
    Differences between Ethernet and Serial BACnet.Play video
  • Setting BACnet/IP in practiceHands-On with BACnet IP Protocol
    Configuring the BACnet/IP server and making panel data available.Play video
  • BACnet MS/TP networkBACnet MSTP Networking for Building Automation
    Demonstration of serial communication for building automation.Play video
  • BACnet verification before assemblyHow to Test BACnet IP & MSTP Prior to On-site Installation
    Communication testing procedure before deployment at the customer.Play video
  • HORNER panels licensed functionsLicensed Features on the Horner OCS
    Overview of additional features and licenses. Check specific support for your model.Play video

License for your specific project

Send panel order code, firmware version and Cscape and brief job description. We will verify the necessary license and propose a range of configuration assistance.

Technical features and license conditions

The HE-VFB1-01 license extends the functionality of the supported HORNER device. It depends on the exact model, its equipment and the corresponding firmware.

License and Activation

Order codeHE-VFB1-01
License unit1 license for 1 controller HORNER; permanent activation by voucher.
SoftwareFree Cscape and firmware supporting the function.
DeliveryLicense / activation voucher. Panel, cables, power supply or technician labor are not included in this item.

Communication and use

Protocol variantsBACnet/IP and BACnet MS/TP in one voucher.
BACnet/IPEthernet connection; corresponding hardware, firmware and network settings.
BACnet MS/TPRS-485; corresponding port, addressing and network connection.
Role in the described applicationA server making available supported panel data objects to a parent system.
Optional extensionMicro X4, X7, X10; CPU200 and CPU250 after verifying the configuration.
Included as standardBACnet IP and MS/TP in XL Prime, CANVAS and CPU300; only BACnet/IP on XLEe and XLTe.

Accessories1