J1939 – license for Horner PLC HMI controllers XL4, XLW, XL6 Prime

J1939 – license for Horner PLC HMI controllers XL4, XLW, XL6 Prime
J1939 – license for Horner PLC HMI controllers XL4, XLW, XL6 Prime

J1939 – license for Horner PLC HMI controllers XL4, XLW, XL6 Prime


Horner Automation

Perpetual SAE J1939 licence for 1 supported HORNER controller. Receive and transmit messages over CAN according to the project. Before ordering, we will verify the panel, firmware and data list of the connected device.

More

Code: HE-VFJ1-01

60 EUR excl. VAT (72,60 EUR Incl. VAT)
Inquire product
pcs

Rezervace termínu

Get a quote

Horner Automation

Perpetual SAE J1939 licence for 1 supported HORNER controller. Receive and transmit messages over CAN according to the project. Before ordering, we will verify the panel, firmware and data list of the connected device.

More

Code: HE-VFJ1-01

HORNER SAE J1939

Display and process J1939 protocol device data.

The SAE J1939 licence allows a supported HORNER controller to communicate with devices using this protocol on the CAN bus. The messages can provide a local view of an engine, power unit or compatible sensor. Prepare the display and associated logic in Cscape.

Optional extensions for example for XL4 Prime, XL6 Prime and XLW Prime. XL7 Prime, XL10 Prime, XL10W Prime, XL15 Prime, CANVAS and CPU300 have J1939 by default.

HORNER SAE J1939 - original manufacturer's material

Send the model of the panel and the description of the desired function.
We will check whether the function is already part of the device, what license you need and what will need to be set.

SAE J1939CAN bus communication
PGN reception and transmissionMapping data by device
1 control unitPerpetual License HE-VFJ1-01

Setting up the J1939 protocol

Configuration of receiving and transmitting J1939 messages in Cscape.

Open the video on YouTube

Use of SAE J1939

Engine overview

On the panel you will see the revolutions, temperatures or other data that the specific engine control unit provides via J1939.

Monitoring a power unit

You will use the selected operating values and states for the operator screen and subsequent logic.

J1939 sensor connection

You plug the data of a compatible sensor or encoder into the HORNER application. An example with an encoder is shown in the video below.

Your own equipment with J1939

You prepare the reception and authorized transmission of messages according to the device protocol and project requirements.

License selection and compatibility

The license makes sense for devices that actually use SAE J1939. Please verify the exact HORNER model, feature availability and connected device message list first.

Order codeHE-VFJ1-01
License unit1 license for 1 controller HORNER; permanent activation by voucher.
XL4 Prime, X5 Prime, XL6 Prime and XLW PrimeJ1939 is an optional paid license.
XL7 Prime, XL10 Prime, XL10W Prime and XL15 PrimeJ1939 is included by default.
CANVAS and CPU300J1939 is included by default.
Other supported modelsFor older XL, selected RCC, Micro and CPU we will verify full code, firmware and activation option.
Standard CscapeFree. This item is a separately paid feature extension.
Price and work of techniciansThe current price of the license is in the menu above. We will price configuration, training and the project according to the agreed scope.
A CAN connection alone does not guarantee J1939 support. Before changing the firmware or protocol, check how the CAN port is currently used and create a full backup.

Selection of messages and operating values

PGN - data groups

In the project, you specify the messages that the panel should receive or transmit. The list is based on the connected device's documentation.

Meaning and conversion of values

For each required data, you verify the location, data format, scale and unit.

Data loss behavior

You set up communication monitoring and program response if expected data stops arriving.

First test J1939

When changing the firmware, applications, screens, configurations and operational data may be deleted. Back up the project and data in advance and choose the right procedure for your model.

  1. Prepare the HORNER code, firmware and message documentation of the connected device.
  2. Verify license, communication speed and required firmware variant.
  3. In Cscape, set addressing and reception of selected PGNs. First, verify a few known values.
  4. If transmission is required, enable it according to the device documentation and test the resulting system behaviour.

License content and project documents

Part of this itemSAE Perpetual License J1939 for one supported controller.
SeparatelyPanel, cabling, network termination CAN and connected equipment.
Necessary documentsList of PGN and data parameters, addresses, communication speed and description of required function.
Our helpLicense verification, mapping design, project consultation and configuration as agreed.

Training and support for the first project

Training in Liberec

We train individuals and groups in our training room in Liberec. We will agree on the scope and date according to the experience of the participants and their tasks.

Self-study

The original Horner Automation Europe video instructions are used for self-study. Translated titles and annotations explain their content, videos remain in English. Video Tutorials Horner Europe.

We offer training in Liberec for individuals and groups. We will agree on the scope and price according to the project; you can also start with a self-study from the manufacturer's videos below.

Encoder connection via J1939

Practical example of connecting the J1939 device to the HORNER control system.

Open the video on YouTube

Original material HORNER

Click to open the original manufacturer's material in a larger view.

Frequently asked questions

Will the panel read all data from each engine?

This depends on the messages and parameters provided by the specific engine control unit. Send its documentation; we will verify support and the required mapping in advance.

Do I need a license for XL7 Prime or CANVAS?

These series have J1939 by default. We'll check your existing support and settings so you don't buy an unnecessary license.

Can I use CANopen instead of J1939?

Both the counterparty and HORNER must use the same protocol. The common physical bus CAN does not imply interchangeability of CANopen and J1939.

Can changing the firmware affect the project?

Changing the firmware can erase the application, screens, configuration and data. Prepare backups and verify the procedure for the exact model before intervention.

Is standard Cscape paid?

The Cscape standard programming software is free. You buy a license that expands a specific function of the supported device, or you order our help with the project separately.

Can you help with the activation and the first project?

Yes. We will verify the model and license, advise on settings and offer training in Liberec. According to the agreement, we will also design the project and ensure assembly with our own technicians. We will confirm the scope and price of the services in the offer.

Why buy from FOXON

Distributor HORNER

We are a distributor of HORNER. We deliver new licenses and devices with warranty, advise on selection and provide technical support.

Selection according to your project

We will discuss technology function, signals and communication. We will compare the entry with the HORNER options and select a suitable product.

Technical support and training

We advise on the use of the equipment and train individuals and groups. For self-study, we recommend the manufacturer's instructions.

Solution design and assembly

If necessary, we will design a solution, prepare a project and install the equipment with our own technicians. We will agree on the scope of work according to the technology.

More than 3 500customers
We deliver tomore than 100 countries of the world
Express delivery?We will check it, contact us immediately.

Video tutorials by topic

The videos are from the producer HORNER and are in English. Translated headings make it easier to choose a topic. The samples use different panels and versions of Cscape; they are not a confirmation of compatibility for every model.

  • Setting up the J1939 protocolJ1939 Protocol
    Configuration of receiving and transmitting J1939 messages in Cscape.Play video
  • Encoder connection via J1939Add a J1939 Encoder to a Horner PLC
    Practical example of connecting the J1939 device to the HORNER control system.Play video
  • HORNER panels licensed functionsLicensed Features on the Horner OCS
    Overview of additional features and licenses. Check specific support for your model.Play video

License for your specific project

Send panel order code, firmware version and Cscape and brief job description. We will verify the necessary license and propose a range of configuration assistance.

Technical features and license conditions

The HE-VFJ1-01 license extends the functionality of the supported HORNER device. It depends on the exact model, its equipment and the corresponding firmware.

License and Activation

Order codeHE-VFJ1-01
License unit1 license for 1 controller HORNER; permanent activation by voucher.
SoftwareFree Cscape and firmware supporting the function.
DeliveryLicense / activation voucher. Panel, cables, power supply or technician labor are not included in this item.

Protocol and project configuration

ProtocolSAE J1939 over CAN.
Data transferConfigured reception and transmission of PGN messages.
SettingsCscape; addressing, PGN and binding of received or transmitted data to the program.
Documentation for the connected deviceDocumentation of messages and parameters including format, scale and units.
Optional at PrimeXL4 Prime, X5 Prime, XL6 Prime and XLW Prime.
Standard for PrimeXL7 Prime, XL10 Prime, XL10W Prime and XL15 Prime.
Other series with standard supportCANVAS and CPU300.
Firmware and CAN portAccording to the model; before changing, verify the existing protocol and back up the project and operational data.

Accessories1