IEN-840GL - VOLKTEK industrial managed Gigabit switch, 16× RJ45
- Switches and Wi-Fi
- Managed Switches
- IEN-840GL - VOLKTEK industrial managed Gigabit switch, 16× RJ45
IEN-840GL - VOLKTEK industrial managed Gigabit switch, 16× RJ45
Sixteen Gigabit ports.
LAMUNGAN management and monitoring.
A Lite Managed industrial switch for connecting PLCs, HMIs and industrial computers. It offers 16 RJ45 ports, the LAMUNGAN web interface, VLANs, network redundancy and integration into monitoring via Modbus TCP.
2 DIP switches for power alarms.
Enable monitoring of the main PWR input and redundant RPS input separately. Configure ports, VLANs and other network functions in LAMUNGAN.

We’ll select a switch for your industrial network
We can help you choose the right model and power supply. We will confirm the price, current stock availability and delivery date.
Managed Ethernet for machines and control cabinets
IEN-840GL connects multiple industrial devices and makes network status available to operators and maintenance staff. Each port automatically adapts to the connected device speed. LAMUNGAN assists with initial configuration, the overview of connected devices and traffic monitoring.
Wizard for initial setup
The wizard guides you through network access and login settings. Complete the basic configuration directly in a web browser.
Topology Map and Dashboard
The topology map shows connected devices and link status. The dashboard clearly displays operating data and switch utilisation.
Technical specifications
| Order reference | VOLKTEK IEN-840GL |
|---|---|
| Model | Lite Managed industrial Ethernet switch |
| Copper ports | 16× 10/100/1000BASE-T, RJ45 connector |
| Automatic adaptation | Auto-negotiation and Auto MDI/MDI-X on all ports |
| Switching capacity | 32 Gbit/s |
| MAC address table | 8K entries |
| Jumbo frames | 10 Kbytes |
| Web interface | LAMUNGAN: Wizard, Topology Map, Dashboard |
| Management and monitoring | HTTPS, SSH, CLI, SNMP v1/v2c/v3, SNMP Trap, Syslog, SNTP, LLDP, DHCP Client, Modbus TCP |
| Configuration | Configuration backup and restore; firmware updates; remote reboot; port settings |
| VLAN | IEEE 802.1Q VLAN, Management VLAN, port isolation |
| Network redundancy | STP/RSTP, ERPS v1/v2 |
| Traffic control | IEEE 802.1p QoS, Flow Control, Storm Control, rate limiting, port mirroring |
| Access security | IEEE 802.1X, ACL, MAC address limit per port, BPDU Guard, BPDU Filter, ROOT Guard |
| Energy saving | IEEE 802.3az Energy Efficient Ethernet (EEE) |
| Power supply | Two inputs: main PWR and redundant RPS, each 12-60 V DC |
| Power and alarm connections | 6-pole terminal block |
| Power consumption | 18 W (12 V / 1.5 A) |
| Alarm output | 1 relay contact, rated at 1 A at 24 V DC |
| DIP switches | 2 switches to enable or disable PWR and RPS alarms |
| Signalling | PWR, RPS, ALM, 1000 and LNK/ACT |
| Housing and installation | IP40 metal housing; DIN rail mounting; wall mounting with optional accessories |
| Operating temperature | -10 to +60 °C |
| Storage temperature | -40 to +85 °C |
| Relative humidity | 5-95 %, non-condensing |
| Dimensions (width × height × depth) | 50 × 160 × 120 mm |
| Weight | 880 g |
Management, network functions and security
VLANs and port isolation
IEEE 802.1Q VLANs and port isolation let you organise network communications. Configure a Management VLAN for management access.
STP/RSTP a ERPS
STP, RSTP and ERPS v1/v2 are available for redundant network paths. Adapt their configuration to the topology and the other devices in the network.
QoS and traffic control
IEEE 802.1p QoS prioritises important communications. Flow Control, Storm Control and rate limiting help manage port load.
Access control
Use HTTPS and SSH for management. Network access can be controlled with 802.1X, ACLs and MAC address limits per port.
Modbus TCP a SNMP
Expose the switch operating and status data to a monitoring system via Modbus TCP or SNMP. Events can be recorded using Syslog.
Configuration backup
Save the settings as a backup and restore them when needed. Firmware updates and remote device reboot are also available.
Power supply, alarm and DIP switches
The PWR and RPS inputs each accept 12-60 V DC. If one power supply fails, the other powers the switch. The relay alarm reports a monitored power fault to equipment in the control cabinet.
Main input monitoring
DIP switch 1 enables or disables the main PWR supply alarm.
Redundant input monitoring
DIP switch 2 enables or disables the redundant RPS supply alarm.
The alarm contact is rated at 1 A at 24 V DC and opens when a monitored fault occurs. The two power inputs do not store energy; use a separate backed-up supply to bridge a complete mains power failure.
Interfaces and installation
Ethernet ports and status LEDs are on the front. The PWR/RPS/ALM terminal block, earth connection and two DIP switches are on the top. The rear bracket is for DIN rail mounting.




Installation in a control cabinet. IP40 does not protect against water. Provide earthing, a SELV supply and separate routing of power and data cables. For Ethernet, use Category 5e or higher cabling. Leave at least 50 mm at the sides and between two switches for ventilation.
Contents of the package
- 1× VOLKTEK IEN-840GL industrial switch
- 1× DIN rail mounting kit
- 1× brief installation guide
The power supply is ordered separately. Wall mounting requires optional mounting accessories.
Documents to download
Original manufacturer documentation in English. All files are also available in the Downloads tab.
LAMUNGAN platform videos
Official VOLKTEK videos present the built-in web interface, topology map and the Lite Managed range. Videos are in English.
LAMUNGAN for network monitoring and management - Overview of the platform used in IEN-840GL.
Getting started with LAMUNGAN
Wizard, Topology Map and Dashboard
Introduction to the platform basic tools.
Lite Managed in industrial networks
Network visibility and remote management
Differences between Unmanaged Premium and Lite Managed ranges.
Frequently Asked Questions
What does Lite Managed mean?
The switch offers LAMUNGAN web management with a setup wizard, topology map and traffic overview. Configure VLANs, traffic priority, ports and access permissions, and use STP/RSTP or ERPS network redundancy.
How do I start configuration?
Connect a computer to an Ethernet port and open the default address 192.168.0.254. The Wizard helps configure network access and the user account. During commissioning, change the default login credentials and adapt the addressing to your network.
What is Modbus TCP used for?
After the service is enabled, the switch provides operating and status data via Modbus TCP for a monitoring system. The user manual contains the register overview and communication settings.
How do the backup power supply and alarm work?
Connect two 12-60 V DC power supplies to PWR and RPS. If one fails, the other continues powering the switch. Use DIP switches to enable the alarm for each input separately. On a monitored fault, the 1 A / 24 V DC relay contact opens. Use a separate backed-up supply to bridge a complete mains power failure.
Does the switch have optical ports or PoE?
IEN-840GL has 16 copper Gigabit RJ45 ports. This model has no optical ports or SFP slots, and the ports do not provide PoE power. We can help select another model if you need these functions.
What’s included in the pack, and can you help me choose accessories?
The package contains one IEN-840GL switch, a DIN rail mounting kit and a quick installation guide. The power supply and wall mounting accessories are selected separately. We advise on power, wiring and basic configuration for your application.
Why buy from FOXON?
We are a VOLKTEK distributor. We supply new, genuine products and assist with their selection and use in industrial networks.
New products with a warranty
We supply the IEN-840GL as a new, genuine VOLKTEK switch with a warranty and manufacturer documentation.
Technical support
We can advise you on selecting a switch, power supply and accessories. We will discuss the wiring and requirements of your application.
Stock availability and delivery
We will check current stock availability and confirm the price and estimated delivery date before you place your order.
Pre-purchase consultation
We help select a model based on device count, transfer speed, power supply and operating conditions. We will discuss network management, VLAN and traffic monitoring requirements.
Delivery of the IEN-840GL switch
A new, original VOLKTEK product. This offer is for the 16-port Gigabit model IEN-840GL from the Lite Managed range. We will confirm price, current stock availability and accessories upon enquiry.
Industrial networking consultancy
Please describe the connected devices, the number of ports required and the desired communication speed. We will discuss power supply, the control cabinet environment and network management requirements. We will help you select a suitable VOLKTEK switch and the necessary accessories.
Enquiry for IEN-840GL
Send the required quantity, connected devices, control cabinet power supply and requirements for VLANs, monitoring and network redundancy. We will prepare a quotation for a new switch and help select accessories.
We’ll select a switch for your industrial network
We can help you choose the right model and power supply. We will confirm the price, current stock availability and delivery date.
Technical specifications of the IEN-840GL
| Order reference | VOLKTEK IEN-840GL |
|---|---|
| Model | Lite Managed industrial Ethernet switch |
| Copper ports | 16× 10/100/1000BASE-T, RJ45 connector |
| Automatic adaptation | Auto-negotiation and Auto MDI/MDI-X on all ports |
| Switching capacity | 32 Gbit/s |
| MAC address table | 8K entries |
| Jumbo frames | 10 Kbytes |
| Web interface | LAMUNGAN: Wizard, Topology Map, Dashboard |
| Management and monitoring | HTTPS, SSH, CLI, SNMP v1/v2c/v3, SNMP Trap, Syslog, SNTP, LLDP, DHCP Client, Modbus TCP |
| Configuration | Configuration backup and restore; firmware updates; remote reboot; port settings |
| VLAN | IEEE 802.1Q VLAN, Management VLAN, port isolation |
| Network redundancy | STP/RSTP, ERPS v1/v2 |
| Traffic control | IEEE 802.1p QoS, Flow Control, Storm Control, rate limiting, port mirroring |
| Access security | IEEE 802.1X, ACL, MAC address limit per port, BPDU Guard, BPDU Filter, ROOT Guard |
| Energy saving | IEEE 802.3az Energy Efficient Ethernet (EEE) |
| Power supply | Two inputs: main PWR and redundant RPS, each 12-60 V DC |
| Power and alarm connections | 6-pole terminal block |
| Power consumption | 18 W (12 V / 1.5 A) |
| Alarm output | 1 relay contact, rated at 1 A at 24 V DC |
| DIP switches | 2 switches to enable or disable PWR and RPS alarms |
| Signalling | PWR, RPS, ALM, 1000 and LNK/ACT |
| Housing and installation | IP40 metal housing; DIN rail mounting; wall mounting with optional accessories |
| Operating temperature | -10 to +60 °C |
| Storage temperature | -40 to +85 °C |
| Relative humidity | 5-95 %, non-condensing |
| Dimensions (width × height × depth) | 50 × 160 × 120 mm |
| Weight | 880 g |

Frequently asked questions about the IEN-840GL
What does Lite Managed mean?
The switch offers LAMUNGAN web management with a setup wizard, topology map and traffic overview. Configure VLANs, traffic priority, ports and access permissions, and use STP/RSTP or ERPS network redundancy.
How do I start configuration?
Connect a computer to an Ethernet port and open the default address 192.168.0.254. The Wizard helps configure network access and the user account. During commissioning, change the default login credentials and adapt the addressing to your network.
What is Modbus TCP used for?
After the service is enabled, the switch provides operating and status data via Modbus TCP for a monitoring system. The user manual contains the register overview and communication settings.
How do the backup power supply and alarm work?
Connect two 12-60 V DC power supplies to PWR and RPS. If one fails, the other continues powering the switch. Use DIP switches to enable the alarm for each input separately. On a monitored fault, the 1 A / 24 V DC relay contact opens. Use a separate backed-up supply to bridge a complete mains power failure.
Does the switch have optical ports or PoE?
IEN-840GL has 16 copper Gigabit RJ45 ports. This model has no optical ports or SFP slots, and the ports do not provide PoE power. We can help select another model if you need these functions.
What’s included in the pack, and can you help me choose accessories?
The package contains one IEN-840GL switch, a DIN rail mounting kit and a quick installation guide. The power supply and wall mounting accessories are selected separately. We advise on power, wiring and basic configuration for your application.