- LAPP 22261001 - PROFIBUS DP terminating resistor, M12 female
LAPP 22261001 - PROFIBUS DP terminating resistor, M12 female
LAPP 22261001 AB-C5-M12FS-PB-TR-SH: PROFIBUS DP terminating resistor, M12 female, B-coded, 5-pin. Shielded version. More
Code: 22261001
LAPP 22261001 AB-C5-M12FS-PB-TR-SH: PROFIBUS DP terminating resistor, M12 female, B-coded, 5-pin. Shielded version. More
Code: 22261001
M12 female terminating resistor
AB-C5-M12FS-PB-TR-SH
LAPP 22261001 AB-C5-M12FS-PB-TR-SH is a straight terminating resistor for PROFIBUS DP metallic segments. The female M12 connector with B-coding connects to the corresponding male M12 port at the physical end of the segment. It has 5 contacts and a shielded design.
Send a photograph of the port and a cable routing diagram. We will check the correct termination arrangement.
Termination for the M12 end port
A terminating resistor is used when installing or maintaining a PROFIBUS DP network with M12 connectors. It terminates one end of an electrical segment where this function is not provided by a suitable built-in terminator. Correct termination reduces signal reflections and helps to maintain stable communication.
A segment is a section of the network in which the electrical signal is the same. Every PROFIBUS DP metallic segment must be properly terminated at both ends with a terminating resistor that is switched on and powered. It is the actual end of the cable run that is decisive, not the lowest or highest station address.
Correct mating connector and B coding
Variant 22261001 is designed for PROFIBUS DP and B coding. Do not select it based solely on the M12 thread. For DeviceNet and CANopen, please check for other suitable coding, resistor networks and pin configurations; we do not offer this product as a universal terminator for these bus systems.
This product has an M12 female connector. For the opposite version, the LAPP 22260722 is available, featuring an unshielded M12 male connector.
Powering the termination at the segment end
This connector has no independent power supply. For correct operation, the corresponding port on the end station must supply power to the termination. Before installation, check the port wiring and what happens when the station is switched off. If termination must remain independent of the station power supply, consider a separately powered active T1 terminator.
When assessing the shutdown or disconnection of a terminal station, consider this in conjunction with the continuity of the cable route and the PLC’s response to the loss of a peripheral device. Maintaining the terminations alone does not guarantee uninterrupted operation of the system.
Installation and inspection of terminations
At the segment end, check the M12 male port, B coding, pin assignment and termination power supply. Fit the terminator without force and tighten it securely. Check the tightening torque and sealing requirements for the specific port and supplied version.
A single segment should have exactly two active terminations at its physical ends. Do not add further resistance to a termination that is already active at the same end. For stations within the segment, leave the switchable termination switched off.
Missing, excessive or unpowered terminations cause signal reflections and impair communication. Symptoms include repeated telegrams or intermittent outages. After any work, we recommend measuring the signal and communication with a ProfiTrace2 tester. The resistor alone will not repair a damaged cable or incorrect shielding.
Technical specifications 22261001
| Manufacturer | LAPP |
|---|---|
| Order number | 22261001 |
| Series | EPIC® DATA PB TR M12 |
| Model designation | AB-C5-M12FS-PB-TR-SH |
| Bus | PROFIBUS DP |
| Features | Termination of one physical end of a metallic segment |
| Connector | M12 female |
| Coding | B (PROFIBUS) |
| Number of contacts | 5 |
| Design | Straight, 180° |
| Shielding | Yes |
| Status indicators | No |
| Net catalogue weight | 34 g |
Delivery and related accessories
The subject of this quotation is the LAPP 22261001 terminating resistor. We will confirm the quantity and packaging in the quotation. We select the connecting cables, M12 mating connectors, active terminator or diagnostic tester separately, depending on the network.
Selection and installation of a terminating resistor
Which port is this terminator designed for?
For the corresponding M12 male connector with B-coding at the actual end of the PROFIBUS DP segment. Also check the electrical connection and power supply to the terminator; the thread alone does not guarantee compatibility.
How many terminating resistors do I need?
A segment is a section of the network in which the electrical signal is the same. Every PROFIBUS DP metallic segment must be properly terminated at both ends with a terminating resistor that is switched on and powered. It is the actual end of the cable run that is decisive, not the lowest or highest station address. There should be exactly two functional terminations at the physical ends of a single segment. Do not add a further resistor to an already active termination at the same end. For stations within the segment, leave the switchable termination switched off.
Is variant 22261001 also suitable for DeviceNet and CANopen?
Variant 22261001 is designed for PROFIBUS DP and B coding. Do not select it based solely on the M12 thread. For DeviceNet and CANopen, please check for other suitable coding, resistor networks and pin configurations; we do not offer this product as a universal terminator for these bus systems.
Does the termination still work when the end station is switched off?
This connector has no independent power supply. For correct operation, the corresponding port on the end station must supply power to the termination. Before installation, check the port wiring and what happens when the station is switched off. If termination must remain independent of the station power supply, consider a separately powered active T1 terminator.
Do I need to change the PLC programme or upload the GSD?
The terminating resistor is not an addressed PROFIBUS device. It needs no GSD file or entry in the hardware configuration. Installing it does not require a PLC program change. Plan work on the cabling around machine operation and verify communication afterwards.
Why order from FOXON
We handle PROFIBUS networks from the selection of connectors right through to signal measurement and troubleshooting. Send us your specific wiring diagram and we’ll help you choose the appropriate terminations.
Choosing the right M12
We will check the male or female connector version, coding and port on the end device.
Topology check
We can help determine the physical ends of the segment and the location of both terminations.
Power supply during maintenance
We will discuss how the terminations behave when the terminal station is switched off and disconnected.
PROFIBUS Diagnostics
We can help verify signal quality, reflections and communication through measurements.
Related components
We will select cables, connectors, repeaters and separately powered terminations.
Delivery Confirmation
Before placing an order, we will confirm the specific design, the number of items and the delivery date.
LAPP Technical Documentation
In the ‘Downloads’ tab, you will find the latest LAPP product information in English for the exact order number 22261001. To verify a specific port, please send us its designation and a photograph.
Open downloadsTechnical specifications 22261001
AB-C5-M12FS-PB-TR-SH - PROFIBUS DP terminating resistor, M12 female.
Identification and use
| Manufacturer | LAPP |
|---|---|
| Order number | 22261001 |
| Series | EPIC® DATA PB TR M12 |
| Model designation | AB-C5-M12FS-PB-TR-SH |
| Bus | PROFIBUS DP |
| Features | Termination of one physical end of a metallic segment |
Connector and design
| Connector | M12 female |
|---|---|
| Coding | B (PROFIBUS) |
| Number of contacts | 5 |
| Design | Straight, 180° |
| Shielding | Yes |
| Status indicators | No |
| Net catalogue weight | 34 g |
Port selection and power supply
At the segment end, check the M12 male port, B coding, pin assignment and termination power supply. Fit the terminator without force and tighten it securely. Check the tightening torque and sealing requirements for the specific port and supplied version.
This connector has no independent power supply. For correct operation, the corresponding port on the end station must supply power to the termination. Before installation, check the port wiring and what happens when the station is switched off. If termination must remain independent of the station power supply, consider a separately powered active T1 terminator.
Termination of the complete segment
A segment is a section of the network in which the electrical signal is the same. Every PROFIBUS DP metallic segment must be properly terminated at both ends with a terminating resistor that is switched on and powered. It is the actual end of the cable run that is decisive, not the lowest or highest station address.
A single segment should have exactly two active terminations at its physical ends. Do not add further resistance to a termination that is already active at the same end. For stations within the segment, leave the switchable termination switched off.
Choosing the right model
Which port is this terminator designed for?
For the corresponding M12 male connector with B-coding at the actual end of the PROFIBUS DP segment. Also check the electrical connection and power supply to the terminator; the thread alone does not guarantee compatibility.
How many terminating resistors do I need?
A segment is a section of the network in which the electrical signal is the same. Every PROFIBUS DP metallic segment must be properly terminated at both ends with a terminating resistor that is switched on and powered. It is the actual end of the cable run that is decisive, not the lowest or highest station address. There should be exactly two functional terminations at the physical ends of a single segment. Do not add a further resistor to an already active termination at the same end. For stations within the segment, leave the switchable termination switched off.
Is variant 22261001 also suitable for DeviceNet and CANopen?
Variant 22261001 is designed for PROFIBUS DP and B coding. Do not select it based solely on the M12 thread. For DeviceNet and CANopen, please check for other suitable coding, resistor networks and pin configurations; we do not offer this product as a universal terminator for these bus systems.
Installation and operation
Does the termination still work when the end station is switched off?
This connector has no independent power supply. For correct operation, the corresponding port on the end station must supply power to the termination. Before installation, check the port wiring and what happens when the station is switched off. If termination must remain independent of the station power supply, consider a separately powered active T1 terminator.
Do I need to change the PLC programme or upload the GSD?
The terminating resistor is not an addressed PROFIBUS device. It needs no GSD file or entry in the hardware configuration. Installing it does not require a PLC program change. Plan work on the cabling around machine operation and verify communication afterwards.
Can I add a resistor to a connector with termination enabled?
A single segment should have exactly two active terminations at its physical ends. Do not add further resistance to a termination that is already active at the same end. For stations within the segment, leave the switchable termination switched off.
What is the difference between the male and female versions?
22260722 has an M12 male connector, 4 pins and an unshielded design. 22261001 has an M12 female connector, 5 pins and a shielded design. Both variants have B coding for PROFIBUS DP. Select the version that is the opposite of the device port and check the wiring.
Will the resistor extend the cable run or create another segment?
No. The Terminator merely terminates the existing segment. It does not regenerate the signal and does not provide galvanic isolation. To extend the run or split the network, use a suitable repeater or ProfiHub.
Measurements and technical advice
How can I check that termination is correct?
Missing, excessive or unpowered terminations cause signal reflections and impair communication. Symptoms include repeated telegrams or intermittent outages. After any work, we recommend measuring the signal and communication with a ProfiTrace2 tester. The resistor alone will not repair a damaged cable or incorrect shielding.
What information should I provide to help choose the right option?
Please send us a photograph and the type of terminal equipment, a close-up of the M12 port, a diagram of the cable route and details of the station’s power supply. We will verify the connector type, the actual end of the segment and the appropriate termination method.
Highlighted items are mandatory.