- LAPP 22260722 - PROFIBUS DP terminating resistor, M12 male
LAPP 22260722 - PROFIBUS DP terminating resistor, M12 male
LAPP 22260722 AB-C4-M12MS-PB-TR: PROFIBUS DP terminating resistor, M12 male, B-coded, 4-pin. Unshielded version, IP65/IP67, -25 to +90 °C. More
Code: 22260722
LAPP 22260722 AB-C4-M12MS-PB-TR: PROFIBUS DP terminating resistor, M12 male, B-coded, 4-pin. Unshielded version, IP65/IP67, -25 to +90 °C. More
Code: 22260722
M12 male terminating resistor
AB-C4-M12MS-PB-TR
LAPP 22260722 AB-C4-M12MS-PB-TR is a straight terminating resistor for PROFIBUS DP metallic segments. The M12 male connector with B-coding connects to the corresponding M12 female port at the physical end of the segment. It has 4 contacts and is unshielded.
Send a photograph of the port and a cable routing diagram. We will check the correct termination arrangement.
Termination for the M12 end port
A terminating resistor is used when installing or maintaining a PROFIBUS DP network with M12 connectors. It terminates one end of an electrical segment where this function is not provided by a suitable built-in terminator. Correct termination reduces signal reflections and helps to maintain stable communication.
A segment is a section of the network in which the electrical signal is the same. Every PROFIBUS DP metallic segment must be properly terminated at both ends with a terminating resistor that is switched on and powered. It is the actual end of the cable run that is decisive, not the lowest or highest station address.
Correct mating connector and B coding
Variant 22260722 is designed for PROFIBUS DP and B coding. Do not select it based solely on the M12 thread. For DeviceNet and CANopen, please check the relevant coding, resistor network and pin configuration; we do not offer this product as a universal terminator for these bus systems.
This product has an M12 male connector. For the reverse configuration, the LAPP 22261001 is available, featuring an M12 female connector and shielding.
Powering the termination at the segment end
This connector has no independent power supply. For correct operation, the corresponding port on the end station must supply power to the termination. Before installation, check the port wiring and what happens when the station is switched off. If termination must remain independent of the station power supply, consider a separately powered active T1 terminator.
When assessing the shutdown or disconnection of a terminal station, consider this in conjunction with the continuity of the cable route and the PLC’s response to the loss of a peripheral device. Maintaining the terminations alone does not guarantee uninterrupted operation of the system.
Resistor network 390 / 220 / 390 Ω
The terminating network consists of resistors R1 (390 Ω), R2 (220 Ω) and R3 (390 Ω), each with a tolerance of ±1 % and a power rating of 0.25 W. The precise connection of the terminals is shown in the diagram in the attached technical data sheet.
The ratings of 60 V DC and 4 A describe the connector and its contacts. They do not mean that this voltage or current should be applied to the PROFIBUS data wires. The termination power supply must match the PROFIBUS port wiring.
Installation and inspection of terminations
At the segment end, check the M12 female port, B coding, pin assignment and termination power supply. Fit the terminator without force and tighten it securely. The specified connector tightening torque is 0.4 Nm. IP65/IP67 applies to a correctly mated and sealed assembly.
A single segment should have exactly two active terminations at its physical ends. Do not add further resistance to a termination that is already active at the same end. For stations within the segment, leave the switchable termination switched off.
Missing, excessive or unpowered terminations cause signal reflections and impair communication. Symptoms include repeated telegrams or intermittent outages. After any work, we recommend measuring the signal and communication with a ProfiTrace2 tester. The resistor alone will not repair a damaged cable or incorrect shielding.
Technical specifications 22260722
| Manufacturer | LAPP |
|---|---|
| Order number | 22260722 |
| Series | EPIC® DATA PB TR M12 |
| Model designation | AB-C4-M12MS-PB-TR |
| Bus | PROFIBUS DP |
| Features | Termination of one physical end of a metallic segment |
| Connector | M12 male |
| Coding | B-inverse (PROFIBUS) |
| Number of contacts | 4 |
| Design | Straight, 180° |
| Shielding | No |
| Status indicators | No |
| Net catalogue weight | 10 g |
| Resistor network | R1: 390 Ω ±1 %; R2: 220 Ω ±1 %; R3: 390 Ω ±1 % |
| The power rating of individual resistors | 0.25 W each |
| Rated voltage of the connector | 60 V DC |
| Rated current of the contacts | 4 A at 40 °C |
| Insulation resistance | ≥100 MΩ |
| Protection rating when correctly mated | IP65 / IP67 |
| Operating temperature | -25 to +90 °C |
| M12 tightening torque | 0.4 Nm |
| Number of connection cycles | ≥100 |
| Contact material / surface | CuSn / Ni/Au |
| Dimensions | Length 56.3 mm; maximum diameter 14.8 mm |
Delivery and related accessories
The subject of this quotation is the LAPP 22260722 terminating resistor. We will confirm the quantity and packaging in the quotation. We select the connecting cables, M12 mating connectors, active terminator or diagnostic tester separately, depending on the network.
Selection and installation of a terminating resistor
Which port is this terminator designed for?
For the corresponding M12 female connector with B-coding at the actual end of the PROFIBUS DP segment. Also check the electrical connection and power supply to the terminator; the thread alone does not guarantee compatibility.
How many terminating resistors do I need?
A segment is a section of the network in which the electrical signal is the same. Every PROFIBUS DP metallic segment must be properly terminated at both ends with a terminating resistor that is switched on and powered. It is the actual end of the cable run that is decisive, not the lowest or highest station address. There should be exactly two functional terminations at the physical ends of a single segment. Do not add a further resistor to an already active termination at the same end. For stations within the segment, leave the switchable termination switched off.
Is variant 22260722 also suitable for DeviceNet and CANopen?
Variant 22260722 is designed for PROFIBUS DP and B coding. Do not select it based solely on the M12 thread. For DeviceNet and CANopen, please check the relevant coding, resistor network and pin configuration; we do not offer this product as a universal terminator for these bus systems.
Does the termination still work when the end station is switched off?
This connector has no independent power supply. For correct operation, the corresponding port on the end station must supply power to the termination. Before installation, check the port wiring and what happens when the station is switched off. If termination must remain independent of the station power supply, consider a separately powered active T1 terminator.
Do I need to change the PLC programme or upload the GSD?
The terminating resistor is not an addressed PROFIBUS device. It needs no GSD file or entry in the hardware configuration. Installing it does not require a PLC program change. Plan work on the cabling around machine operation and verify communication afterwards.
Why order from FOXON
We handle PROFIBUS networks from the selection of connectors right through to signal measurement and troubleshooting. Send us your specific wiring diagram and we’ll help you choose the appropriate terminations.
Choosing the right M12
We will check the male or female connector version, coding and port on the end device.
Topology check
We can help determine the physical ends of the segment and the location of both terminations.
Power supply during maintenance
We will discuss how the terminations behave when the terminal station is switched off and disconnected.
PROFIBUS Diagnostics
We can help verify signal quality, reflections and communication through measurements.
Related components
We will select cables, connectors, repeaters and separately powered terminations.
Delivery Confirmation
Before placing an order, we will confirm the specific design, the number of items and the delivery date.
LAPP Technical Documentation
In the ‘Downloads’ tab, you will find the latest LAPP product information in English for order number 22260722. The attached technical data sheet also includes dimensions, the tightening torque and a diagram of the resistor network.
Open downloadsTechnical specifications 22260722
AB-C4-M12MS-PB-TR - PROFIBUS DP terminating resistor, M12 male.
Identification and use
| Manufacturer | LAPP |
|---|---|
| Order number | 22260722 |
| Series | EPIC® DATA PB TR M12 |
| Model designation | AB-C4-M12MS-PB-TR |
| Bus | PROFIBUS DP |
| Features | Termination of one physical end of a metallic segment |
Connector and design
| Connector | M12 male |
|---|---|
| Coding | B-inverse (PROFIBUS) |
| Number of contacts | 4 |
| Design | Straight, 180° |
| Shielding | No |
| Status indicators | No |
| Net catalogue weight | 10 g |
Electrical and operational data
| Resistor network | R1: 390 Ω ±1 %; R2: 220 Ω ±1 %; R3: 390 Ω ±1 % |
|---|---|
| The power rating of individual resistors | 0.25 W each |
| Rated voltage of the connector | 60 V DC |
| Rated current of the contacts | 4 A at 40 °C |
| Insulation resistance | ≥100 MΩ |
| Protection rating when correctly mated | IP65 / IP67 |
| Operating temperature | -25 to +90 °C |
| M12 tightening torque | 0.4 Nm |
| Number of connection cycles | ≥100 |
| Contact material / surface | CuSn / Ni/Au |
| Dimensions | Length 56.3 mm; maximum diameter 14.8 mm |
Port selection and power supply
At the segment end, check the M12 female port, B coding, pin assignment and termination power supply. Fit the terminator without force and tighten it securely. The specified connector tightening torque is 0.4 Nm. IP65/IP67 applies to a correctly mated and sealed assembly.
This connector has no independent power supply. For correct operation, the corresponding port on the end station must supply power to the termination. Before installation, check the port wiring and what happens when the station is switched off. If termination must remain independent of the station power supply, consider a separately powered active T1 terminator.
Termination of the complete segment
A segment is a section of the network in which the electrical signal is the same. Every PROFIBUS DP metallic segment must be properly terminated at both ends with a terminating resistor that is switched on and powered. It is the actual end of the cable run that is decisive, not the lowest or highest station address.
A single segment should have exactly two active terminations at its physical ends. Do not add further resistance to a termination that is already active at the same end. For stations within the segment, leave the switchable termination switched off.
Choosing the right model
Which port is this terminator designed for?
For the corresponding M12 female connector with B-coding at the actual end of the PROFIBUS DP segment. Also check the electrical connection and power supply to the terminator; the thread alone does not guarantee compatibility.
How many terminating resistors do I need?
A segment is a section of the network in which the electrical signal is the same. Every PROFIBUS DP metallic segment must be properly terminated at both ends with a terminating resistor that is switched on and powered. It is the actual end of the cable run that is decisive, not the lowest or highest station address. There should be exactly two functional terminations at the physical ends of a single segment. Do not add a further resistor to an already active termination at the same end. For stations within the segment, leave the switchable termination switched off.
Is variant 22260722 also suitable for DeviceNet and CANopen?
Variant 22260722 is designed for PROFIBUS DP and B coding. Do not select it based solely on the M12 thread. For DeviceNet and CANopen, please check the relevant coding, resistor network and pin configuration; we do not offer this product as a universal terminator for these bus systems.
Installation and operation
Does the termination still work when the end station is switched off?
This connector has no independent power supply. For correct operation, the corresponding port on the end station must supply power to the termination. Before installation, check the port wiring and what happens when the station is switched off. If termination must remain independent of the station power supply, consider a separately powered active T1 terminator.
Do I need to change the PLC programme or upload the GSD?
The terminating resistor is not an addressed PROFIBUS device. It needs no GSD file or entry in the hardware configuration. Installing it does not require a PLC program change. Plan work on the cabling around machine operation and verify communication afterwards.
Can I add a resistor to a connector with termination enabled?
A single segment should have exactly two active terminations at its physical ends. Do not add further resistance to a termination that is already active at the same end. For stations within the segment, leave the switchable termination switched off.
What is the difference between the male and female versions?
22260722 has an M12 male connector, 4 pins and an unshielded design. 22261001 has an M12 female connector, 5 pins and a shielded design. Both variants have B coding for PROFIBUS DP. Select the version that is the opposite of the device port and check the wiring.
Will the resistor extend the cable run or create another segment?
No. The Terminator merely terminates the existing segment. It does not regenerate the signal and does not provide galvanic isolation. To extend the run or split the network, use a suitable repeater or ProfiHub.
Measurements and technical advice
How can I check that termination is correct?
Missing, excessive or unpowered terminations cause signal reflections and impair communication. Symptoms include repeated telegrams or intermittent outages. After any work, we recommend measuring the signal and communication with a ProfiTrace2 tester. The resistor alone will not repair a damaged cable or incorrect shielding.
What information should I provide to help choose the right option?
Please send us a photograph and the type of terminal equipment, a close-up of the M12 port, a diagram of the cable route and details of the station’s power supply. We will verify the connector type, the actual end of the segment and the appropriate termination method.

PROFIBUS: 3 Sins and 10 Tips
The PROFIBUS industrial bus is highly tolerant and will forgive many faults. But if a critical fault occurs—or several small ones accumulate—you will definitely notice. That’s why this aging industrial network deserves attention. Even if faults on your network are still rare, they will gradually accumulate. What do our technicians recommend? What are their 10 tips for maintaining PROFIBUS?
Highlighted items are mandatory.