SIMATIC STEP 7 Professional PowerPack for TIA Portal – Basic to Professional extension - SIEMENS license type: STEP 7 Professional V21 PowerPack – Basic V19–V21 → Professional V19–V21, e-mail delivery
- SIEMENS
- Software
- STEP 7 for TIA Portal
- SIMATIC STEP 7 Professional PowerPack for TIA Portal – Basic to Professional extension
SIMATIC STEP 7 Professional PowerPack for TIA Portal – Basic to Professional extension - SIEMENS license type: STEP 7 Professional V21 PowerPack – Basic V19–V21 → Professional V19–V21, e-mail delivery
Extension of an existing SIMATIC STEP 7 Basic license to STEP 7 Professional. It extends programming options to SIMATIC S7-300/-400/-1200/-1500 PLCs and WinAC in the TIA Portal environment, including WinCC Basic / WinCC Unified Basic for configuring SIMATIC Basic Panels and Unified Basic Panels. More
Code: 6ES7822-1AE23-0YC5
Extension of an existing SIMATIC STEP 7 Basic license to STEP 7 Professional. It extends programming options to SIMATIC S7-300/-400/-1200/-1500 PLCs and WinAC in the TIA Portal environment, including WinCC Basic / WinCC Unified Basic for configuring SIMATIC Basic Panels and Unified Basic Panels. More
Code: 6ES7822-1AE23-0YC5
Options 2
| SIEMENS license type | Code | Availability | Price excl. VAT | |
|---|---|---|---|---|
| STEP 7 Professional V21 PowerPack – Basic V19–V21 → Professional V19–V21, e-mail delivery | 6ES7822-1AE23-0YC5 | Delivery 1-2 days |
On request
|
|
| STEP 7 Professional V19 PowerPack – Basic V19 → Professional V19, USB key | 6ES7822-1AA23-0YC5 | Delivery in 1-2 weeks |
On request
|
SIMATIC STEP 7 Professional PowerPack
PowerPack upgrades an existing STEP 7 Basic licence to STEP 7 Professional. This offer includes two variants with different version ranges, so you must select the order number based on your original licence.
Do you need a new licence or an extension?
We will match the order number to your project, your existing licence and your preferred delivery method.

Software usage
PowerPack makes sense if you already have STEP 7 Basic and need to work with S7-1500 or other systems supported by Professional. It is not a substitute for a new full licence for a computer on which you do not yet have the appropriate basic authorisation.
Technical and licensing information
| Purpose | Upgrade from the Basic edition to the Professional edition |
|---|---|
| USB-based version | Basic V19 to Professional V19 |
| Electronic version | Basic V19-V21 to Professional V19-V21 |
| Licence type | Floating License / Floating License Download |
| Target systems | S7-1200/1500, S7-300/400, WinAC and the corresponding Basic HMI, depending on the specific version |
Edition upgrades and version changes
PowerPack extends the edition. It cannot be inferred from the specified V19-V21 range that any V19 licence will automatically become a V21 licence, the highest version. Check the starting version, the target version and any further upgrades. It is particularly important to note that the physical USB version is only available for V19.
Licence options and delivery methods
| Order number | Purpose of the variant | Delivery |
|---|---|---|
| 6ES7822-1AA23-0YC5 | Basic V19 to Professional V19 | USB |
| 6ES7822-1AE23-0YC5 | Basic V19-V21 to Professional V19-V21 | Electronically |
Scope of delivery and licence management
For these variants, the delivery of the licence key is the key factor. The key itself does not imply that the package also includes the new STEP 7 base environment. We will verify the availability of installation files and the required base software based on the selected code.
For electronic delivery, we require the recipient’s email address. Before reinstalling or replacing a hard drive, ensure that licence keys are transferred securely; do not consider simply copying files to be a confirmed licence transfer.
Project and computer compatibility
Please send us the project version, the exact CPU or HMI type, the firmware, and the edition and version of Windows. Together, we will check the configuration in Siemens Compatibility Tool. A licence for a newer version does not in itself guarantee that every older project can be opened.
Frequently asked questions
Is the PowerPack sufficient without a Basic licence?
No. This is an extension of an existing, corresponding STEP 7 Basic licence.
Will I receive the Professional V21 version with the USB option?
Code 6ES7822-1AA23-0YC5 is intended for Basic V19 to Professional V19. The range V19-V21 is specified for the electronic code.
What do I need to provide to select the correct option?
Please specify the exact name of the Basic licence, its version, the required version of TIA Portal and the type of PLC. We will then verify the PowerPack and any necessary upgrade accordingly.
Why buy software from FOXON
New genuine licences
We supply new Siemens software licences. The specific authorisation is always determined by the order number and the relevant licence terms.
Check selection
We will compare the edition, version and required scope with your PLC, HMI or software configuration.
Delivery depending on the variant
Before placing an order, we will confirm the method of delivery (electronic or physical) and the recipient’s details.
Licensing support
Please send us the details of your existing licence. We will check which new licence, upgrade or extension is suitable.
Siemens software enquiry
Please send us the order number, software version, PLC or HMI type, and whether you already hold a licence. For licence extensions, please specify the required number of objects, connections or users.
Request a licence or supportWe will send you a non-binding quotation within 1 hour.Highlighted items are mandatory.







