- Ethernet IO remote analog inputs outputs 0-10V: 1xAI, 1xAO, Modbus TCP, REST, MQTT, OPC UA
Ethernet IO remote analog inputs outputs 0-10V: 1xAI, 1xAO, Modbus TCP, REST, MQTT, OPC UA
Industrial module for remote monitoring and collection of analog signals 1x AI 0-10V a 1x AO 0-10V. Analog data can be collected and controlled via OPC UA, REST, MQTT, Modbus TCP or Web Server. Built-in data logger for data archiving via FTP, Excel, ODBC or internal memory with min 150days, max 99 years, storage after 15,30sec or 1,5,15,60min. Alarm system with email notification, automatic control of outputs according to input. Data readout after 2sec, 12-48VDC or PoE power supply, DIN mounting. More
Code: 57762
Industrial module for remote monitoring and collection of analog signals 1x AI 0-10V a 1x AO 0-10V. Analog data can be collected and controlled via OPC UA, REST, MQTT, Modbus TCP or Web Server. Built-in data logger for data archiving via FTP, Excel, ODBC or internal memory with min 150days, max 99 years, storage after 15,30sec or 1,5,15,60min. Alarm system with email notification, automatic control of outputs according to input. Data readout after 2sec, 12-48VDC or PoE power supply, DIN mounting. More
Code: 57762
0–10 V analogue signals available via Ethernet
The W&T 57762 is a network module for measuring and adjusting 0–10 V voltage signals. It features two channels that can be configured as either analogue inputs or outputs, a web interface, internal data logging, and support for OPC UA, MQTT, REST and Modbus TCP.
Do you need to select or order the W&T 57762?
Please send us the required quantity and a description of the wiring configuration. We will check availability and suitable accessories.
Successor model
W&T lists the successor model 57162 for this product. The specifications on this page relate to the original order number 57762. Before selecting a replacement, we will verify the wiring, functions and suitability for the specific application.
Usage
It is used to connect sensors with a 0–10 V output, to record measured values and to control analogue actuators via Ethernet. Box2Box mode allows an analogue value to be transmitted between two appropriately configured modules.
Technical specifications for W&T 57762
| Voltage input | 0–10 V, 1 MΩ |
|---|---|
| Voltage output | 0–10 V, max. 20 mA Option to connect a Sense sensor lead Short-circuit protection |
| Connecting analogue inputs/outputs | 8-pin terminal block Conductor cross-sectional area 0.2–1.3 mm² Length of stripped section: 6–8 mm |
| Network interface | Automatic 10/100BaseT detection RJ45 IPv6 on request |
| Galvanic isolation | Measurement inputs relative to the network interface: min. 1500 V |
| Power supply | Power-over-Ethernet (PoE) or 12–48 V DC (±10 %) |
| Current consumption | PoE Class 1 (0.44–3.84 W) typ. 100 mA at 24 V DC with an external power supply |
| Signalling | 1 Power LED 2× network status LEDs 4 LEDs for status and faults |
| Resolution | Voltage input: 1.25 mV |
| Measurement error | max. 0.5% FSR (full scale 0 to 10 V) TA = 0–60 °C |
| Save interval | 15, 30 s, 1, 5, 15, 60 min |
| History capacity | min. 150 days, max. 99 years |
| Updates to measured values for network queries and alarms | 2 per second |
| Housing and mounting | Compact plastic housing for DIN rail mounting 105 × 22 × 75 mm (length × width × height) |
| Degree of protection | IP20 |
| Weight | approx. 140 g |
| Ambient storage temperature | -40 to +70 °C |
| Operating ambient temperature | 0 to +60 °C |
| Contents of the delivery | 1x Web-IO Analogue In/Out 2x 0 to 10 V PoE for DIN rail mounting 1× brief user guide in German and English |
Analogue signals and measurement recording
- The input has an impedance of 1 MΩ. The output provides a maximum of 20 mA and allows connection of the Sense lead. The output is short-circuit protected.
- Internal measurements are updated twice per second. The recording interval is selected individually: 15 or 30 seconds, or 1, 5, 15 or 60 minutes.
- Up to 12 configurable alarm notifications are available, including email and SNMP. Data can be made available to a parent application or logged via FTP and other supported services.
- The history capacity depends on the selected interval. The stated range of 150 days to 99 years describes the volume of records, not the guaranteed operating life of the device.
Commissioning and accessories
Before connecting, select the function of each channel, the sensor connection method and the permitted load. Then configure the network, the scale of the displayed quantity, the communication services, the recording interval and the alarm limits. Check the terminal block connections against the manual for this model to ensure they are correct.
Contents of the delivery
- 1x Web-IO Analogue In/Out 2x 0–10 V PoE
- for DIN rail mounting
- 1× brief user guide in German and English
Frequently Asked Questions
Are there two inputs and a further two outputs?
No. The module has two physical channels, which can be configured as inputs or outputs. This does not increase the total number of channels.
What do I need to check on the connected sensor?
The input has an impedance of 1 MΩ. The output provides a maximum of 20 mA and allows connection of the Sense lead. The output is short-circuit protected.
Is the recording interval the same as the measurement period?
No. Measurements are updated twice per second, whilst the history is saved according to a separately configured recording interval.
Why order from FOXON?
Before placing an order, we will check the current availability of the part and confirm the estimated delivery date. We will assist you in selecting the equipment and necessary accessories based on the wiring configuration and required communication. We will confirm the warranty terms and the scope of any diagnostics or repairs for the specific quotation.
Documentation and technical consultancy
Technical data and documentation W&T 57762
Manuals, firmware and tools for this model can also be found in the Downloads tab. For service enquiries, please use sale and repair of FOXON industrial parts.
Do you need to select or order the W&T 57762?
Please send us the required quantity and a description of the wiring configuration. We will check availability and suitable accessories.
Diagrams and illustrations

Further related links
Technical specifications for W&T 57762
| Voltage input | 0–10 V, 1 MΩ |
|---|---|
| Voltage output | 0–10 V, max. 20 mA Option to connect a Sense sensor lead Short-circuit protection |
| Connecting analogue inputs/outputs | 8-pin terminal block Conductor cross-sectional area 0.2–1.3 mm² Length of stripped section: 6–8 mm |
| Network interface | Automatic 10/100BaseT detection RJ45 IPv6 on request |
| Galvanic isolation | Measurement inputs relative to the network interface: min. 1500 V |
| Power supply | Power-over-Ethernet (PoE) or 12–48 V DC (±10 %) |
| Current consumption | PoE Class 1 (0.44–3.84 W) typ. 100 mA at 24 V DC with an external power supply |
| Signalling | 1 Power LED 2× network status LEDs 4 LEDs for status and faults |
| Resolution | Voltage input: 1.25 mV |
| Measurement error | max. 0.5% FSR (full scale 0 to 10 V) TA = 0–60 °C |
| Save interval | 15, 30 s, 1, 5, 15, 60 min |
| History capacity | min. 150 days, max. 99 years |
| Updates to measured values for network queries and alarms | 2 per second |
| Housing and mounting | Compact plastic housing for DIN rail mounting 105 × 22 × 75 mm (length × width × height) |
| Degree of protection | IP20 |
| Weight | approx. 140 g |
| Ambient storage temperature | -40 to +70 °C |
| Operating ambient temperature | 0 to +60 °C |
| Contents of the delivery | 1x Web-IO Analogue In/Out 2x 0 to 10 V PoE for DIN rail mounting 1× brief user guide in German and English |

VIDEO: Easily Collect Machine Data via OPC UA & MQTT
At the beginning of 2024 we introduced a new product from the German manufacturer of industrial modules W&T to the Czech market. Check out our short videos to see how easy it is to set up and use W&T sensors and digital and analogue inputs and outputs for data acquisition using OPC UA and MQTT communications.