Converter CANopen / Modbus TCP Slave - HD67505-A1
Converter CANopen / Modbus TCP Slave - HD67505-A1
The ADFweb HD67505-A1 makes CANopen data available to a Modbus TCP client. It responds as a Modbus TCP Server over Ethernet and provides configured access to CANopen objects and messages. More
Code: HD67505-A1
The ADFweb HD67505-A1 makes CANopen data available to a Modbus TCP client. It responds as a Modbus TCP Server over Ethernet and provides configured access to CANopen objects and messages. More
Code: HD67505-A1
ADFweb HD67505-A1
CANopen / Modbus TCP Slave
The ADFweb HD67505-A1 makes CANopen data available to a Modbus TCP client. It responds as a Modbus TCP Server over Ethernet and provides configured access to CANopen objects and messages.
We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.
Converter applications
Use it with a PLC, HMI or SCADA operating as a Modbus TCP Client. It supports a maximum of 10 simultaneous connections; CANopen data can be mapped using SDO, PDO and EMCY.
Technical specifications HD67505-A1
| Order code | HD67505-A1 |
|---|---|
| Protocol connection | CANopen / Modbus TCP Slave |
| Converter roles | CANopen SDO Client, PDO and EMCY; Modbus TCP Slave/Server |
| Interfaces and ports | 1× CANopen; 1× Ethernet RJ45 |
| Simultaneous Modbus TCP connections | maximum 10 |
| Power supply | Confirm against the label and hardware version before ordering |
| Power consumption at 24 V DC | 3.5 W |
| Operating temperature | -40 °C to +85 °C |
| Mounting | 35 mm DIN rail |
| Dimensions of the version shown (D × W × H) | 123 × 22.5 × 90.7 mm |
| Device weight | approximately 200 g |
| Configuration software | SW67505 |
We will confirm the supply range for this model against the specific hardware version. Always check the device label before connecting the power supply.
Communication and configuration
In SW67505, configure CANopen, Modbus TCP and the register mapping to SDO objects, PDOs and EMCY messages. Check byte and word order and the required read/write operations.
This model is a Modbus TCP Server, not a client polling other servers. The CANopen settings must match the objects and operating state of the connected nodes.
Supply and accessories
Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.
Documentation and software
Diagrams and hardware version

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.
Frequently asked questions
Is knowing the two protocols enough?
The device roles, physical interfaces and data to be transferred must also be checked. This model is a Modbus TCP Server, not a client polling other servers. The CANopen settings must match the objects and operating state of the connected nodes.
How is this converter configured?
In SW67505, configure CANopen, Modbus TCP and the register mapping to SDO objects, PDOs and EMCY messages. Check byte and word order and the required read/write operations.
What information should I send to check the selection?
Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.
FOXON support with selection and ordering
Selection based on your devices
We will review the specific connection, communication roles and required data.
Availability check
Before you place an order, we will confirm current availability and the possible delivery date.
Documentation for the exact order code
We select the documentation and configuration tool using the complete order code.
Accessories for your installation
We will include the requested accessories in the quotation to suit the connection arrangement.
Choosing the correct version
Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.
This model is a Modbus TCP Server, not a client polling other servers. The CANopen settings must match the objects and operating state of the connected nodes.
Converter enquiry HD67505-A1
Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.
Request the converterTechnical specifications HD67505-A1
| Order code | HD67505-A1 |
|---|---|
| Protocol connection | CANopen / Modbus TCP Slave |
| Converter roles | CANopen SDO Client, PDO and EMCY; Modbus TCP Slave/Server |
| Interfaces and ports | 1× CANopen; 1× Ethernet RJ45 |
| Simultaneous Modbus TCP connections | maximum 10 |
| Power supply | Confirm against the label and hardware version before ordering |
| Power consumption at 24 V DC | 3.5 W |
| Operating temperature | -40 °C to +85 °C |
| Mounting | 35 mm DIN rail |
| Dimensions of the version shown (D × W × H) | 123 × 22.5 × 90.7 mm |
| Device weight | approximately 200 g |
| Configuration software | SW67505 |
We will confirm the supply range for this model against the specific hardware version. Always check the device label before connecting the power supply.