Converter Modbus TCP Client / Modbus RTU Slave - HD67510-A1

Converter Modbus TCP Client / Modbus RTU Slave - HD67510-A1


ADFweb

The ADFweb HD67510-A1 connects a serial Modbus Master system to Modbus TCP Server devices. It responds as a Slave on the serial line and communicates as a Modbus TCP Master over Ethernet. More

Code: HD67510-A1

209 EUR excl. VAT (252,89 EUR Incl. VAT)
Delivery 3-8 days
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote
ADFweb

The ADFweb HD67510-A1 connects a serial Modbus Master system to Modbus TCP Server devices. It responds as a Slave on the serial line and communicates as a Modbus TCP Master over Ethernet. More

Code: HD67510-A1

ADFweb HD67510-A1

Modbus TCP Client / Modbus RTU Slave

The ADFweb HD67510-A1 connects a serial Modbus Master system to Modbus TCP Server devices. It responds as a Slave on the serial line and communicates as a Modbus TCP Master over Ethernet.

We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.

Request the converter
Modbus TCP Client / Modbus RTU SlaveProtocol connection
35 mm DIN railHardware version
SW67510Configuration tool

Converter applications

It is suitable for installations where a serial Modbus Master needs to access Modbus TCP devices. Before selecting the converter, check the required function codes, register addressing and the RS232 or RS485 interface.

Technical specifications HD67510-A1

Order codeHD67510-A1
Protocol connectionModbus TCP Client / Modbus RTU Slave
Converter rolesModbus TCP Master/Client; serial Modbus Slave
Interfaces and ports1× Ethernet RJ45; 1× RS232; 1× RS485
Serial data rateup to 115,200 bit/s
Power supply8-24 V AC / 12-35 V DC
Power consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)123 × 22.5 × 90.7 mm
Device weightapproximately 200 g
Configuration softwareSW67510

For an older device, check the hardware version and connections against its label.

Communication and configuration

In Compositor SW67510, configure serial Modbus and the Modbus TCP connections. The communication addresses and data transfer must match both the connected serial Master and the Ethernet Servers.

The communication roles are the opposite of those on the HD67507-A1. Choose this model for an existing serial Master; the A1 version is not a Wi-Fi variant.

Supply and accessories

Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.

Documentation and software

Diagrams and hardware version

Version shown - HD67510-A1
Version shown - HD67510-A1
Dimensional drawing of the version shown - HD67510-A1
Dimensional drawing of the version shown - HD67510-A1

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.

Frequently asked questions

Is knowing the two protocols enough?

The device roles, physical interfaces and data to be transferred must also be checked. The communication roles are the opposite of those on the HD67507-A1. Choose this model for an existing serial Master; the A1 version is not a Wi-Fi variant.

How is this converter configured?

In Compositor SW67510, configure serial Modbus and the Modbus TCP connections. The communication addresses and data transfer must match both the connected serial Master and the Ethernet Servers.

What information should I send to check the selection?

Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.

FOXON support with selection and ordering

Selection based on your devices

We will review the specific connection, communication roles and required data.

Availability check

Before you place an order, we will confirm current availability and the possible delivery date.

Documentation for the exact order code

We select the documentation and configuration tool using the complete order code.

Accessories for your installation

We will include the requested accessories in the quotation to suit the connection arrangement.

Choosing the correct version

Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.

The communication roles are the opposite of those on the HD67507-A1. Choose this model for an existing serial Master; the A1 version is not a Wi-Fi variant.

Converter enquiry HD67510-A1

Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.

Request the converter

Technical specifications HD67510-A1

Order codeHD67510-A1
Protocol connectionModbus TCP Client / Modbus RTU Slave
Converter rolesModbus TCP Master/Client; serial Modbus Slave
Interfaces and ports1× Ethernet RJ45; 1× RS232; 1× RS485
Serial data rateup to 115,200 bit/s
Power supply8-24 V AC / 12-35 V DC
Power consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)123 × 22.5 × 90.7 mm
Device weightapproximately 200 g
Configuration softwareSW67510

For an older device, check the hardware version and connections against its label.