Converter Modbus TCP Client / Modbus RTU Slave - HD67510-A1
- Converters and gateways
- Converter Modbus TCP Client / Modbus RTU Slave - HD67510-A1
Converter Modbus TCP Client / Modbus RTU Slave - HD67510-A1
The ADFweb HD67510-A1 connects a serial Modbus Master system to Modbus TCP Server devices. It responds as a Slave on the serial line and communicates as a Modbus TCP Master over Ethernet. More
Code: HD67510-A1
The ADFweb HD67510-A1 connects a serial Modbus Master system to Modbus TCP Server devices. It responds as a Slave on the serial line and communicates as a Modbus TCP Master over Ethernet. More
Code: HD67510-A1
ADFweb HD67510-A1
Modbus TCP Client / Modbus RTU Slave
The ADFweb HD67510-A1 connects a serial Modbus Master system to Modbus TCP Server devices. It responds as a Slave on the serial line and communicates as a Modbus TCP Master over Ethernet.
We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.
Converter applications
It is suitable for installations where a serial Modbus Master needs to access Modbus TCP devices. Before selecting the converter, check the required function codes, register addressing and the RS232 or RS485 interface.
Technical specifications HD67510-A1
| Order code | HD67510-A1 |
|---|---|
| Protocol connection | Modbus TCP Client / Modbus RTU Slave |
| Converter roles | Modbus TCP Master/Client; serial Modbus Slave |
| Interfaces and ports | 1× Ethernet RJ45; 1× RS232; 1× RS485 |
| Serial data rate | up to 115,200 bit/s |
| Power supply | 8-24 V AC / 12-35 V DC |
| Power consumption at 24 V DC | 3.5 W |
| Operating temperature | -40 °C to +85 °C |
| Mounting | 35 mm DIN rail |
| Dimensions of the version shown (D × W × H) | 123 × 22.5 × 90.7 mm |
| Device weight | approximately 200 g |
| Configuration software | SW67510 |
For an older device, check the hardware version and connections against its label.
Communication and configuration
In Compositor SW67510, configure serial Modbus and the Modbus TCP connections. The communication addresses and data transfer must match both the connected serial Master and the Ethernet Servers.
The communication roles are the opposite of those on the HD67507-A1. Choose this model for an existing serial Master; the A1 version is not a Wi-Fi variant.
Supply and accessories
Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.
Documentation and software
Diagrams and hardware version


The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.
Frequently asked questions
Is knowing the two protocols enough?
The device roles, physical interfaces and data to be transferred must also be checked. The communication roles are the opposite of those on the HD67507-A1. Choose this model for an existing serial Master; the A1 version is not a Wi-Fi variant.
How is this converter configured?
In Compositor SW67510, configure serial Modbus and the Modbus TCP connections. The communication addresses and data transfer must match both the connected serial Master and the Ethernet Servers.
What information should I send to check the selection?
Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.
FOXON support with selection and ordering
Selection based on your devices
We will review the specific connection, communication roles and required data.
Availability check
Before you place an order, we will confirm current availability and the possible delivery date.
Documentation for the exact order code
We select the documentation and configuration tool using the complete order code.
Accessories for your installation
We will include the requested accessories in the quotation to suit the connection arrangement.
Choosing the correct version
Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.
The communication roles are the opposite of those on the HD67507-A1. Choose this model for an existing serial Master; the A1 version is not a Wi-Fi variant.
Converter enquiry HD67510-A1
Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.
Request the converterTechnical specifications HD67510-A1
| Order code | HD67510-A1 |
|---|---|
| Protocol connection | Modbus TCP Client / Modbus RTU Slave |
| Converter roles | Modbus TCP Master/Client; serial Modbus Slave |
| Interfaces and ports | 1× Ethernet RJ45; 1× RS232; 1× RS485 |
| Serial data rate | up to 115,200 bit/s |
| Power supply | 8-24 V AC / 12-35 V DC |
| Power consumption at 24 V DC | 3.5 W |
| Operating temperature | -40 °C to +85 °C |
| Mounting | 35 mm DIN rail |
| Dimensions of the version shown (D × W × H) | 123 × 22.5 × 90.7 mm |
| Device weight | approximately 200 g |
| Configuration software | SW67510 |
For an older device, check the hardware version and connections against its label.