Converter CAN / Modbus TCP Master - HD67514-A1
Converter CAN / Modbus TCP Master - HD67514-A1
The ADFweb HD67514-A1 connects CAN messages to Modbus TCP Server devices. As a Modbus TCP Master, it controls register reads and writes and maps them to configured CAN frames. More
Code: HD67514-A1
The ADFweb HD67514-A1 connects CAN messages to Modbus TCP Server devices. As a Modbus TCP Master, it controls register reads and writes and maps them to configured CAN frames. More
Code: HD67514-A1
ADFweb HD67514-A1
CAN / Modbus TCP Master
The ADFweb HD67514-A1 connects CAN messages to Modbus TCP Server devices. As a Modbus TCP Master, it controls register reads and writes and maps them to configured CAN frames.
We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.
Converter applications
Use it with devices having a documented CAN message structure and Modbus TCP Slave/Server devices on the other side. Define message identifiers, byte contents and corresponding Modbus registers before selection.
Technical specifications HD67514-A1
| Order code | HD67514-A1 |
|---|---|
| Protocol connection | CAN / Modbus TCP Master |
| Converter roles | CAN frames; Modbus TCP Master/Client |
| Interfaces and ports | 1× CAN; 1× Ethernet RJ45 |
| Power supply | Confirm against the label and hardware version before ordering |
| Power consumption at 24 V DC | 3.5 W |
| Operating temperature | -40 °C to +85 °C |
| Mounting | 35 mm DIN rail |
| Dimensions of the version shown (D × W × H) | 123 × 22.5 × 90.7 mm |
| Device weight | approximately 200 g |
| Configuration software | SW67514 |
We will confirm the supply range for this model against the specific hardware version. Always check the device label before connecting the power supply.
Communication and configuration
In SW67514, configure CAN, Modbus TCP and the rules for reading and writing values through CAN messages. Data types and byte order must match both connected systems.
This model works with CAN frames. Select the corresponding model for CANopen; for a Modbus TCP Client at the other end, use a Server version, such as HD67515-A1.
Supply and accessories
Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.
Documentation and software
Diagrams and hardware version

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.
Frequently asked questions
Is knowing the two protocols enough?
The device roles, physical interfaces and data to be transferred must also be checked. This model works with CAN frames. Select the corresponding model for CANopen; for a Modbus TCP Client at the other end, use a Server version, such as HD67515-A1.
How is this converter configured?
In SW67514, configure CAN, Modbus TCP and the rules for reading and writing values through CAN messages. Data types and byte order must match both connected systems.
What information should I send to check the selection?
Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.
FOXON support with selection and ordering
Selection based on your devices
We will review the specific connection, communication roles and required data.
Availability check
Before you place an order, we will confirm current availability and the possible delivery date.
Documentation for the exact order code
We select the documentation and configuration tool using the complete order code.
Accessories for your installation
We will include the requested accessories in the quotation to suit the connection arrangement.
Choosing the correct version
Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.
This model works with CAN frames. Select the corresponding model for CANopen; for a Modbus TCP Client at the other end, use a Server version, such as HD67515-A1.
Converter enquiry HD67514-A1
Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.
Request the converterTechnical specifications HD67514-A1
| Order code | HD67514-A1 |
|---|---|
| Protocol connection | CAN / Modbus TCP Master |
| Converter roles | CAN frames; Modbus TCP Master/Client |
| Interfaces and ports | 1× CAN; 1× Ethernet RJ45 |
| Power supply | Confirm against the label and hardware version before ordering |
| Power consumption at 24 V DC | 3.5 W |
| Operating temperature | -40 °C to +85 °C |
| Mounting | 35 mm DIN rail |
| Dimensions of the version shown (D × W × H) | 123 × 22.5 × 90.7 mm |
| Device weight | approximately 200 g |
| Configuration software | SW67514 |
We will confirm the supply range for this model against the specific hardware version. Always check the device label before connecting the power supply.