Converter PROFINET Slave / Modbus RTU Master - HD67602-485-A1

Converter PROFINET Slave / Modbus RTU Master - HD67602-485-A1


ADFweb

The ADFweb HD67602-485-A1 connects serial Modbus RTU Slave devices to a PROFINET system. It controls data reading and writing as a Modbus Master over RS485 and operates as a Slave on PROFINET. More

Code: HD67602-485-A1

349 EUR excl. VAT (422,29 EUR Incl. VAT)
Delivery 3-8 days
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote
ADFweb

The ADFweb HD67602-485-A1 connects serial Modbus RTU Slave devices to a PROFINET system. It controls data reading and writing as a Modbus Master over RS485 and operates as a Slave on PROFINET. More

Code: HD67602-485-A1

ADFweb HD67602-485-A1

PROFINET Slave / Modbus RTU Master

The ADFweb HD67602-485-A1 connects serial Modbus RTU Slave devices to a PROFINET system. It controls data reading and writing as a Modbus Master over RS485 and operates as a Slave on PROFINET.

We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.

Request the converter
PROFINET Slave / Modbus RTU MasterProtocol connection
512 bytes in each directionData capacity
SW67602Configuration tool

Converter applications

Use it to integrate meters, drives or other Modbus RTU devices into a PROFINET control system. Up to 512 bytes are available for reading and 512 bytes for writing; configure the data mapping to match the registers of the connected devices.

Technical specifications HD67602-485-A1

Order codeHD67602-485-A1
Protocol connectionPROFINET Slave / Modbus RTU Master
Converter rolesPROFINET Slave; Modbus RTU Master over RS485
Interfaces and ports2× PROFINET RJ45; 1× RS485
Serial data rateup to 115,200 bit/s
Data capacity512 bytes in each direction
Power supply8-24 V AC / 12-35 V DC
Power consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)123 × 22.5 × 90.7 mm
Device weightapproximately 200 g
Configuration softwareSW67602

For an older device, check the hardware version and connections against its label.

Communication and configuration

In Compositor SW67602, configure PROFINET, the RS485 serial line and the Modbus read and write requests. Define their mapping to the PROFINET data areas and prepare integration into the controller project.

This order code uses RS485. The RS232 and RS422 versions have different codes. The connected serial device must operate as a Modbus Slave; Ethernet is not a Modbus TCP interface on this model.

Supply and accessories

Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.

Documentation and software

Diagrams and hardware version

Dimensional drawing of the version shown - HD67602-485-A1
Dimensional drawing of the version shown - HD67602-485-A1

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.

Frequently asked questions

Is knowing the two protocols enough?

The device roles, physical interfaces and data to be transferred must also be checked. This order code uses RS485. The RS232 and RS422 versions have different codes. The connected serial device must operate as a Modbus Slave; Ethernet is not a Modbus TCP interface on this model.

How is this converter configured?

In Compositor SW67602, configure PROFINET, the RS485 serial line and the Modbus read and write requests. Define their mapping to the PROFINET data areas and prepare integration into the controller project.

What information should I send to check the selection?

Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.

FOXON support with selection and ordering

Selection based on your devices

We will review the specific connection, communication roles and required data.

Availability check

Before you place an order, we will confirm current availability and the possible delivery date.

Documentation for the exact order code

We select the documentation and configuration tool using the complete order code.

Accessories for your installation

We will include the requested accessories in the quotation to suit the connection arrangement.

Choosing the correct version

Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.

This order code uses RS485. The RS232 and RS422 versions have different codes. The connected serial device must operate as a Modbus Slave; Ethernet is not a Modbus TCP interface on this model.

Converter enquiry HD67602-485-A1

Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.

Request the converter

Technical specifications HD67602-485-A1

Order codeHD67602-485-A1
Protocol connectionPROFINET Slave / Modbus RTU Master
Converter rolesPROFINET Slave; Modbus RTU Master over RS485
Interfaces and ports2× PROFINET RJ45; 1× RS485
Serial data rateup to 115,200 bit/s
Data capacity512 bytes in each direction
Power supply8-24 V AC / 12-35 V DC
Power consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)123 × 22.5 × 90.7 mm
Device weightapproximately 200 g
Configuration softwareSW67602

For an older device, check the hardware version and connections against its label.