The ADFweb HD67502-A1 connects CANopen to a serial Modbus RTU Master system. It responds as a Modbus Slave over RS232 or RS485 and makes configured CANopen values available. More

Code: HD67502-A1

299 EUR excl. VAT (361,79 EUR Incl. VAT)
Delivery 3-8 days
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote
ADFweb

The ADFweb HD67502-A1 connects CANopen to a serial Modbus RTU Master system. It responds as a Modbus Slave over RS232 or RS485 and makes configured CANopen values available. More

Code: HD67502-A1

ADFweb HD67502-A1

CANopen / Modbus RTU Slave

The ADFweb HD67502-A1 connects CANopen to a serial Modbus RTU Master system. It responds as a Modbus Slave over RS232 or RS485 and makes configured CANopen values available.

We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.

Request the converter
CANopen / Modbus RTU SlaveProtocol connection
35 mm DIN railHardware version
SW67502Configuration tool

Converter applications

Use it to provide a serial Modbus Master with access to SDO objects, PDOs and EMCY messages. The gateway supports configuration of up to 1,500 SDOs, 64 RPDOs and 32 TPDOs.

Technical specifications HD67502-A1

Order codeHD67502-A1
Protocol connectionCANopen / Modbus RTU Slave
Converter rolesCANopen SDO Client and PDO; Modbus RTU Slave
Interfaces and ports1× CANopen; 1× RS485; 1× RS232; 1× Ethernet RJ45
Serial data rateup to 115,200 bit/s
Power supplyConfirm against the label and hardware version before ordering
Power consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)123 × 22.5 × 90.7 mm
Device weightapproximately 200 g
Configuration softwareSW67502

We will confirm the supply range for this model against the specific hardware version. Always check the device label before connecting the power supply.

Communication and configuration

In SW67502, configure CANopen, select the RS232 or RS485 serial interface and map data to Modbus registers. The Ethernet port is used for device configuration and updates.

Modbus is serial on this model. The RJ45 connector does not provide Modbus TCP; select the corresponding TCP version for an Ethernet Modbus client.

Supply and accessories

Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.

Documentation and software

Diagrams and hardware version

Dimensional drawing of the version shown - HD67502-A1
Dimensional drawing of the version shown - HD67502-A1

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.

Frequently asked questions

Is knowing the two protocols enough?

The device roles, physical interfaces and data to be transferred must also be checked. Modbus is serial on this model. The RJ45 connector does not provide Modbus TCP; select the corresponding TCP version for an Ethernet Modbus client.

How is this converter configured?

In SW67502, configure CANopen, select the RS232 or RS485 serial interface and map data to Modbus registers. The Ethernet port is used for device configuration and updates.

What information should I send to check the selection?

Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.

FOXON support with selection and ordering

Selection based on your devices

We will review the specific connection, communication roles and required data.

Availability check

Before you place an order, we will confirm current availability and the possible delivery date.

Documentation for the exact order code

We select the documentation and configuration tool using the complete order code.

Accessories for your installation

We will include the requested accessories in the quotation to suit the connection arrangement.

Choosing the correct version

Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.

Modbus is serial on this model. The RJ45 connector does not provide Modbus TCP; select the corresponding TCP version for an Ethernet Modbus client.

Converter enquiry HD67502-A1

Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.

Request the converter

Technical specifications HD67502-A1

Order codeHD67502-A1
Protocol connectionCANopen / Modbus RTU Slave
Converter rolesCANopen SDO Client and PDO; Modbus RTU Slave
Interfaces and ports1× CANopen; 1× RS485; 1× RS232; 1× Ethernet RJ45
Serial data rateup to 115,200 bit/s
Power supplyConfirm against the label and hardware version before ordering
Power consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)123 × 22.5 × 90.7 mm
Device weightapproximately 200 g
Configuration softwareSW67502

We will confirm the supply range for this model against the specific hardware version. Always check the device label before connecting the power supply.