Converter CAN / Modbus TCP Slave - HD67515-A1

Converter CAN / Modbus TCP Slave - HD67515-A1


ADFweb

The ADFweb HD67515-A1 makes CAN message data available to a Modbus TCP client. It responds as a Modbus TCP Server over Ethernet and maps registers to CAN frame reception and transmission. More

Code: HD67515-A1

329 EUR excl. VAT (398,09 EUR Incl. VAT)
Delivery 3-8 days
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote
ADFweb

The ADFweb HD67515-A1 makes CAN message data available to a Modbus TCP client. It responds as a Modbus TCP Server over Ethernet and maps registers to CAN frame reception and transmission. More

Code: HD67515-A1

ADFweb HD67515-A1

CAN / Modbus TCP Slave

The ADFweb HD67515-A1 makes CAN message data available to a Modbus TCP client. It responds as a Modbus TCP Server over Ethernet and maps registers to CAN frame reception and transmission.

We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.

Request the converter
CAN / Modbus TCP SlaveProtocol connection
35 mm DIN railHardware version
SW67515Configuration tool

Converter applications

Use it to connect CAN devices to a PLC, HMI or SCADA operating as a Modbus TCP Client. Configuration requires the CAN message identifiers and the meaning of the transferred data.

Technical specifications HD67515-A1

Order codeHD67515-A1
Protocol connectionCAN / Modbus TCP Slave
Converter rolesCAN frames; Modbus TCP Slave/Server
Interfaces and ports1× CAN; 1× Ethernet RJ45
Power supplyConfirm against the label and hardware version before ordering
Power consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)123 × 22.5 × 90.7 mm
Device weightapproximately 200 g
Configuration softwareSW67515

We will confirm the supply range for this model against the specific hardware version. Always check the device label before connecting the power supply.

Communication and configuration

In SW67515, configure CAN, Modbus TCP and the frames whose contents are read or written through Modbus registers. Check data types, byte order and transfer timing.

This is a Modbus TCP Server. Select a Master version to independently poll other Modbus TCP Servers. Physical CAN support does not automatically provide CANopen or J1939 support.

Supply and accessories

Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.

Documentation and software

Diagrams and hardware version

Dimensional drawing of the version shown - HD67515-A1
Dimensional drawing of the version shown - HD67515-A1

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.

Frequently asked questions

Is knowing the two protocols enough?

The device roles, physical interfaces and data to be transferred must also be checked. This is a Modbus TCP Server. Select a Master version to independently poll other Modbus TCP Servers. Physical CAN support does not automatically provide CANopen or J1939 support.

How is this converter configured?

In SW67515, configure CAN, Modbus TCP and the frames whose contents are read or written through Modbus registers. Check data types, byte order and transfer timing.

What information should I send to check the selection?

Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.

FOXON support with selection and ordering

Selection based on your devices

We will review the specific connection, communication roles and required data.

Availability check

Before you place an order, we will confirm current availability and the possible delivery date.

Documentation for the exact order code

We select the documentation and configuration tool using the complete order code.

Accessories for your installation

We will include the requested accessories in the quotation to suit the connection arrangement.

Choosing the correct version

Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.

This is a Modbus TCP Server. Select a Master version to independently poll other Modbus TCP Servers. Physical CAN support does not automatically provide CANopen or J1939 support.

Converter enquiry HD67515-A1

Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.

Request the converter

Technical specifications HD67515-A1

Order codeHD67515-A1
Protocol connectionCAN / Modbus TCP Slave
Converter rolesCAN frames; Modbus TCP Slave/Server
Interfaces and ports1× CAN; 1× Ethernet RJ45
Power supplyConfirm against the label and hardware version before ordering
Power consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)123 × 22.5 × 90.7 mm
Device weightapproximately 200 g
Configuration softwareSW67515

We will confirm the supply range for this model against the specific hardware version. Always check the device label before connecting the power supply.