The ADFweb HD67515-A1 makes CAN message data available to a Modbus TCP client. It responds as a Modbus TCP Server over Ethernet and maps registers to CAN frame reception and transmission. More
Code: HD67515-A1
The ADFweb HD67515-A1 makes CAN message data available to a Modbus TCP client. It responds as a Modbus TCP Server over Ethernet and maps registers to CAN frame reception and transmission. More
Code: HD67515-A1
ADFweb HD67515-A1
CAN / Modbus TCP Slave
The ADFweb HD67515-A1 makes CAN message data available to a Modbus TCP client. It responds as a Modbus TCP Server over Ethernet and maps registers to CAN frame reception and transmission.
We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.
Converter applications
Use it to connect CAN devices to a PLC, HMI or SCADA operating as a Modbus TCP Client. Configuration requires the CAN message identifiers and the meaning of the transferred data.
Technical specifications HD67515-A1
| Order code | HD67515-A1 |
|---|---|
| Protocol connection | CAN / Modbus TCP Slave |
| Converter roles | CAN frames; Modbus TCP Slave/Server |
| Interfaces and ports | 1× CAN; 1× Ethernet RJ45 |
| Power supply | Confirm against the label and hardware version before ordering |
| Power consumption at 24 V DC | 3.5 W |
| Operating temperature | -40 °C to +85 °C |
| Mounting | 35 mm DIN rail |
| Dimensions of the version shown (D × W × H) | 123 × 22.5 × 90.7 mm |
| Device weight | approximately 200 g |
| Configuration software | SW67515 |
We will confirm the supply range for this model against the specific hardware version. Always check the device label before connecting the power supply.
Communication and configuration
In SW67515, configure CAN, Modbus TCP and the frames whose contents are read or written through Modbus registers. Check data types, byte order and transfer timing.
This is a Modbus TCP Server. Select a Master version to independently poll other Modbus TCP Servers. Physical CAN support does not automatically provide CANopen or J1939 support.
Supply and accessories
Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.
Documentation and software
Diagrams and hardware version

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.
Frequently asked questions
Is knowing the two protocols enough?
The device roles, physical interfaces and data to be transferred must also be checked. This is a Modbus TCP Server. Select a Master version to independently poll other Modbus TCP Servers. Physical CAN support does not automatically provide CANopen or J1939 support.
How is this converter configured?
In SW67515, configure CAN, Modbus TCP and the frames whose contents are read or written through Modbus registers. Check data types, byte order and transfer timing.
What information should I send to check the selection?
Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.
FOXON support with selection and ordering
Selection based on your devices
We will review the specific connection, communication roles and required data.
Availability check
Before you place an order, we will confirm current availability and the possible delivery date.
Documentation for the exact order code
We select the documentation and configuration tool using the complete order code.
Accessories for your installation
We will include the requested accessories in the quotation to suit the connection arrangement.
Choosing the correct version
Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.
This is a Modbus TCP Server. Select a Master version to independently poll other Modbus TCP Servers. Physical CAN support does not automatically provide CANopen or J1939 support.
Converter enquiry HD67515-A1
Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.
Request the converterTechnical specifications HD67515-A1
| Order code | HD67515-A1 |
|---|---|
| Protocol connection | CAN / Modbus TCP Slave |
| Converter roles | CAN frames; Modbus TCP Slave/Server |
| Interfaces and ports | 1× CAN; 1× Ethernet RJ45 |
| Power supply | Confirm against the label and hardware version before ordering |
| Power consumption at 24 V DC | 3.5 W |
| Operating temperature | -40 °C to +85 °C |
| Mounting | 35 mm DIN rail |
| Dimensions of the version shown (D × W × H) | 123 × 22.5 × 90.7 mm |
| Device weight | approximately 200 g |
| Configuration software | SW67515 |
We will confirm the supply range for this model against the specific hardware version. Always check the device label before connecting the power supply.