The ADFweb HD67507-A1 connects a Modbus TCP client to serial Modbus RTU Slave devices. It responds as a Server over Ethernet and forwards requests as a Master on the serial side. More

Code: HD67507-A1

199 EUR excl. VAT (240,79 EUR Incl. VAT)
Delivery 3-8 days
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote
ADFweb

The ADFweb HD67507-A1 connects a Modbus TCP client to serial Modbus RTU Slave devices. It responds as a Server over Ethernet and forwards requests as a Master on the serial side. More

Code: HD67507-A1

ADFweb HD67507-A1

Modbus TCP Server / Modbus RTU Master

The ADFweb HD67507-A1 connects a Modbus TCP client to serial Modbus RTU Slave devices. It responds as a Server over Ethernet and forwards requests as a Master on the serial side.

We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.

Request the converter
Modbus TCP Server / Modbus RTU MasterProtocol connection
35 mm DIN railHardware version
SW67507Configuration tool

Converter applications

Use it between a PLC, HMI or SCADA operating as a Modbus TCP Client and serial devices on RS232 or RS485. The A1 version supports a maximum of ten simultaneous Ethernet connections.

Technical specifications HD67507-A1

Order codeHD67507-A1
Protocol connectionModbus TCP Server / Modbus RTU Master
Converter rolesModbus TCP Slave/Server; serial Modbus Master
Interfaces and ports1× Ethernet RJ45; 1× RS232; 1× RS485
Simultaneous Modbus TCP connectionsmaximum 10
Serial data rateup to 115,200 bit/s
Power supply8-24 V AC / 12-35 V DC
Power consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)123 × 22.5 × 90.7 mm
Device weightapproximately 200 g
Configuration softwareSW67507

For an older device, check the hardware version and connections against its label.

Communication and configuration

In SW67507, configure Modbus TCP and the serial communication parameters. Routing mode forwards requests using the same addresses; NAT mode translates device and data addresses using a configured Modbus table.

The HD67507-A1 is not a Modbus TCP client that independently polls other servers. Check the communication roles at both ends and the selected serial interface. The A1 version does not have Wi-Fi.

Supply and accessories

Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.

Documentation and software

Diagrams and hardware version

Version shown - HD67507-A1
Version shown - HD67507-A1
Dimensional drawing of the version shown - HD67507-A1
Dimensional drawing of the version shown - HD67507-A1

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.

Frequently asked questions

Is knowing the two protocols enough?

The device roles, physical interfaces and data to be transferred must also be checked. The HD67507-A1 is not a Modbus TCP client that independently polls other servers. Check the communication roles at both ends and the selected serial interface. The A1 version does not have Wi-Fi.

How is this converter configured?

In SW67507, configure Modbus TCP and the serial communication parameters. Routing mode forwards requests using the same addresses; NAT mode translates device and data addresses using a configured Modbus table.

What information should I send to check the selection?

Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.

FOXON support with selection and ordering

Selection based on your devices

We will review the specific connection, communication roles and required data.

Availability check

Before you place an order, we will confirm current availability and the possible delivery date.

Documentation for the exact order code

We select the documentation and configuration tool using the complete order code.

Accessories for your installation

We will include the requested accessories in the quotation to suit the connection arrangement.

Choosing the correct version

Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.

The HD67507-A1 is not a Modbus TCP client that independently polls other servers. Check the communication roles at both ends and the selected serial interface. The A1 version does not have Wi-Fi.

Converter enquiry HD67507-A1

Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.

Request the converter

Technical specifications HD67507-A1

Order codeHD67507-A1
Protocol connectionModbus TCP Server / Modbus RTU Master
Converter rolesModbus TCP Slave/Server; serial Modbus Master
Interfaces and ports1× Ethernet RJ45; 1× RS232; 1× RS485
Simultaneous Modbus TCP connectionsmaximum 10
Serial data rateup to 115,200 bit/s
Power supply8-24 V AC / 12-35 V DC
Power consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)123 × 22.5 × 90.7 mm
Device weightapproximately 200 g
Configuration softwareSW67507

For an older device, check the hardware version and connections against its label.