Converter BACnet MS/TP Slave / PROFINET Slave - HD67679-MSTP-A1
- Converters and gateways
- Converter BACnet MS/TP Slave / PROFINET Slave - HD67679-MSTP-A1
Converter BACnet MS/TP Slave / PROFINET Slave - HD67679-MSTP-A1
The ADFweb HD67679-MSTP-A1 is an industrial BACnet MS/TP Slave / PROFINET Slave converter. It connects both communication sides through a configured data map. More
Code: HD67679-MSTP-A1
The ADFweb HD67679-MSTP-A1 is an industrial BACnet MS/TP Slave / PROFINET Slave converter. It connects both communication sides through a configured data map. More
Code: HD67679-MSTP-A1
ADFweb HD67679-MSTP-A1
BACnet MS/TP Slave / PROFINET Slave
The ADFweb HD67679-MSTP-A1 is an industrial BACnet MS/TP Slave / PROFINET Slave converter. It connects both communication sides through a configured data map.
We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.
Converter applications
Exchange process data between a PLC with a PROFINET Controller and a supervisory BACnet MS/TP system. It is an IO-Device on PROFINET and a Slave on BACnet.
Technical specifications HD67679-MSTP-A1
| Order code | HD67679-MSTP-A1 |
|---|---|
| Protocol connection | BACnet MS/TP Slave / PROFINET Slave |
| Converter roles | BACnet MS/TP Slave; PROFINET Slave |
| Interfaces | RS485; Ethernet RJ45 |
| BACnet objects | up to 2000 objects in total |
| Converter power supply | 8-24 V AC / 12-35 V DC |
| Consumption at 24 V DC | 3.5 W |
| Operating temperature | -40 °C to +85 °C |
| Mounting | 35 mm DIN rail |
| Dimensions of the supplied version | To be confirmed for the hardware version before ordering |
| Device weight | approximately 200 g |
| Configuration software | SW67679 |
For an older device, check the hardware version and connections against its label.
Communication and configuration
Prepare the configuration in SW67679. Configure the PROFINET device in the PLC project, process data lengths, MS/TP addressing and BACnet objects accessible to the supervisory system.
This version uses BACnet MS/TP over RS485. Prepare device addresses, bus parameters and the object list with data types and required read/write operations. Master and Slave roles must match the counterparts; the BACnet/IP version has a different interface.
Supply and accessories
Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.
Documentation and software
Diagrams and hardware version

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.
Frequently asked questions
Is knowing the two protocols enough?
The device roles, physical interfaces and data to be transferred must also be checked. This version uses BACnet MS/TP over RS485. Prepare device addresses, bus parameters and the object list with data types and required read/write operations. Master and Slave roles must match the counterparts; the BACnet/IP version has a different interface.
How is this converter configured?
Prepare the configuration in SW67679. Configure the PROFINET device in the PLC project, process data lengths, MS/TP addressing and BACnet objects accessible to the supervisory system.
What information should I send to check the selection?
Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.
FOXON support with selection and ordering
Selection based on your devices
We will review the specific connection, communication roles and required data.
Availability check
Before you place an order, we will confirm current availability and the possible delivery date.
Documentation for the exact order code
We select the documentation and configuration tool using the complete order code.
Accessories for your installation
We will include the requested accessories in the quotation to suit the connection arrangement.
Choosing the correct version
Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.
This version uses BACnet MS/TP over RS485. Prepare device addresses, bus parameters and the object list with data types and required read/write operations. Master and Slave roles must match the counterparts; the BACnet/IP version has a different interface.
Converter enquiry HD67679-MSTP-A1
Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.
Request the converterTechnical specifications HD67679-MSTP-A1
| Order code | HD67679-MSTP-A1 |
|---|---|
| Protocol connection | BACnet MS/TP Slave / PROFINET Slave |
| Converter roles | BACnet MS/TP Slave; PROFINET Slave |
| Interfaces | RS485; Ethernet RJ45 |
| BACnet objects | up to 2000 objects in total |
| Converter power supply | 8-24 V AC / 12-35 V DC |
| Consumption at 24 V DC | 3.5 W |
| Operating temperature | -40 °C to +85 °C |
| Mounting | 35 mm DIN rail |
| Dimensions of the supplied version | To be confirmed for the hardware version before ordering |
| Device weight | approximately 200 g |
| Configuration software | SW67679 |
For an older device, check the hardware version and connections against its label.