Converter OPC UA Client / EtherNet/IP Slave - HD67B16-B2

Converter OPC UA Client / EtherNet/IP Slave - HD67B16-B2


ADFweb

The ADFweb HD67B16-B2 connects an EtherNet/IP control system to OPC UA Server data. It operates as an EtherNet/IP Slave and accesses OPC UA variables as a Client. More

Code: HD67B16-B2

299 EUR excl. VAT (361,79 EUR Incl. VAT)
Delivery 3-8 days
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote
ADFweb

The ADFweb HD67B16-B2 connects an EtherNet/IP control system to OPC UA Server data. It operates as an EtherNet/IP Slave and accesses OPC UA variables as a Client. More

Code: HD67B16-B2

ADFweb HD67B16-B2

OPC UA Client / EtherNet/IP Slave

The ADFweb HD67B16-B2 connects an EtherNet/IP control system to OPC UA Server data. It operates as an EtherNet/IP Slave and accesses OPC UA variables as a Client.

We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.

Request the converter
OPC UA Client / EtherNet/IP SlaveProtocol connection
1500 bytes in each directionData capacity
SW67B16Configuration tool

Converter applications

Use it to exchange values between an EtherNet/IP Scanner and OPC UA Servers. Configure data mapping in the gateway and the Scanner project; reading and writing capacity is up to 1,500 bytes in each direction.

Technical specifications HD67B16-B2

Order codeHD67B16-B2
Protocol connectionOPC UA Client / EtherNet/IP Slave
Converter rolesOPC UA Client; EtherNet/IP Slave/Adapter
Interfaces and portsEthernet RJ45
Data capacity1500 bytes in each direction
Power supplyConfirm against the label and hardware version before ordering
Consumption at 24 V DC4 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)60 × 35 × 95 mm
Device weightapproximately 200 g
Configuration softwareSW67B16

We will confirm the supply range for this model against the specific hardware version. Always check the device label before connecting the power supply.

Communication and configuration

In SW67B16, configure the OPC UA Client and server variable access, EtherNet/IP network settings and input/output area sizes. Align the configuration with the EtherNet/IP controller project.

The gateway requires an EtherNet/IP Scanner and an accessible OPC UA Server. It does not operate as an EtherNet/IP Master. Check OPC UA security and data areas against the specific project.

Supply and accessories

Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.

Documentation and software

Diagrams and hardware version

Dimensional drawing of the version shown - HD67B16-B2
Dimensional drawing of the version shown - HD67B16-B2

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.

Frequently asked questions

Is knowing the two protocols enough?

The device roles, physical interfaces and data to be transferred must also be checked. The gateway requires an EtherNet/IP Scanner and an accessible OPC UA Server. It does not operate as an EtherNet/IP Master. Check OPC UA security and data areas against the specific project.

How is this converter configured?

In SW67B16, configure the OPC UA Client and server variable access, EtherNet/IP network settings and input/output area sizes. Align the configuration with the EtherNet/IP controller project.

What information should I send to check the selection?

Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.

FOXON support with selection and ordering

Selection based on your devices

We will review the specific connection, communication roles and required data.

Availability check

Before you place an order, we will confirm current availability and the possible delivery date.

Documentation for the exact order code

We select the documentation and configuration tool using the complete order code.

Accessories for your installation

We will include the requested accessories in the quotation to suit the connection arrangement.

Choosing the correct version

Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.

The gateway requires an EtherNet/IP Scanner and an accessible OPC UA Server. It does not operate as an EtherNet/IP Master. Check OPC UA security and data areas against the specific project.

Converter enquiry HD67B16-B2

Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.

Request the converter

Technical specifications HD67B16-B2

Order codeHD67B16-B2
Protocol connectionOPC UA Client / EtherNet/IP Slave
Converter rolesOPC UA Client; EtherNet/IP Slave/Adapter
Interfaces and portsEthernet RJ45
Data capacity1500 bytes in each direction
Power supplyConfirm against the label and hardware version before ordering
Consumption at 24 V DC4 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)60 × 35 × 95 mm
Device weightapproximately 200 g
Configuration softwareSW67B16

We will confirm the supply range for this model against the specific hardware version. Always check the device label before connecting the power supply.