Converter BACnet/IP Server / M-Bus Master - HD67056-B2-20

Converter BACnet/IP Server / M-Bus Master - HD67056-B2-20


ADFweb

The ADFweb HD67056-B2-20 connects M-Bus meters to BACnet/IP Server communication. It transfers values from the configured M-Bus line to BACnet objects. More

Code: HD67056-B2-20

359 EUR excl. VAT (434,39 EUR Incl. VAT)
Delivery 3-8 days
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote
ADFweb

The ADFweb HD67056-B2-20 connects M-Bus meters to BACnet/IP Server communication. It transfers values from the configured M-Bus line to BACnet objects. More

Code: HD67056-B2-20

ADFweb HD67056-B2-20

BACnet/IP Server / M-Bus Master

The ADFweb HD67056-B2-20 connects M-Bus meters to BACnet/IP Server communication. It transfers values from the configured M-Bus line to BACnet objects.

We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.

Request the converter
BACnet/IP Server / M-Bus MasterProtocol connection
35 mm DIN railHardware version
SW67056Configuration tool

Converter applications

Use it to collect data from up to 20 standard M-Bus devices. Select the required measurements and their mapping to the supervisory system; check addressing and bus loading during design.

Technical specifications HD67056-B2-20

Order codeHD67056-B2-20
Protocol connectionBACnet/IP Server / M-Bus Master
Converter rolesBACnet/IP Server; M-Bus Master
Interfaces and portsM-Bus; Ethernet RJ45
M-Bus line capacityup to 20 standard M-Bus devices
Power supply15-21 V AC / 18-35 V DC
Consumption at 24 V DC, no load / full load3.5 W / 4 W
Operating temperatureConfirm for the specific hardware version
Mounting35 mm DIN rail
Dimensions of the housing shown (D × W × H)60 × 71 × 95 mm
Device weightapproximately 200 g
Configuration softwareSW67056

For an older device, check the hardware version and connections against its label.

Communication and configuration

In SW67056, configure M-Bus, meter addresses, BACnet/IP and the objects exposing the measured values.

This order code uses BACnet/IP over Ethernet. The supervisory BACnet system must operate as a Client. MS/TP requires a different version.

Supply and accessories

Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.

Documentation and software

Diagrams and hardware version

Dimensional drawing of the version shown - HD67056-B2-20
Dimensional drawing of the version shown - HD67056-B2-20

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.

Frequently asked questions

Is knowing the two protocols enough?

The device roles, physical interfaces and data to be transferred must also be checked. This order code uses BACnet/IP over Ethernet. The supervisory BACnet system must operate as a Client. MS/TP requires a different version.

How is this converter configured?

In SW67056, configure M-Bus, meter addresses, BACnet/IP and the objects exposing the measured values.

What information should I send to check the selection?

Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.

FOXON support with selection and ordering

Selection based on your devices

We will review the specific connection, communication roles and required data.

Availability check

Before you place an order, we will confirm current availability and the possible delivery date.

Documentation for the exact order code

We select the documentation and configuration tool using the complete order code.

Accessories for your installation

We will include the requested accessories in the quotation to suit the connection arrangement.

Choosing the correct version

Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.

This order code uses BACnet/IP over Ethernet. The supervisory BACnet system must operate as a Client. MS/TP requires a different version.

Converter enquiry HD67056-B2-20

Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.

Request the converter

Technical specifications HD67056-B2-20

Order codeHD67056-B2-20
Protocol connectionBACnet/IP Server / M-Bus Master
Converter rolesBACnet/IP Server; M-Bus Master
Interfaces and portsM-Bus; Ethernet RJ45
M-Bus line capacityup to 20 standard M-Bus devices
Power supply15-21 V AC / 18-35 V DC
Consumption at 24 V DC, no load / full load3.5 W / 4 W
Operating temperatureConfirm for the specific hardware version
Mounting35 mm DIN rail
Dimensions of the housing shown (D × W × H)60 × 71 × 95 mm
Device weightapproximately 200 g
Configuration softwareSW67056

For an older device, check the hardware version and connections against its label.