Converter BACnet/IP Server / Modbus TCP Server - HD67674-IP-A1

Converter BACnet/IP Server / Modbus TCP Server - HD67674-IP-A1


ADFweb

The ADFweb HD67674-IP-A1 connects BACnet/IP to Modbus TCP. It operates as a BACnet Server and Modbus TCP Server, transferring values through configured BACnet objects and Modbus registers. More

Code: HD67674-IP-A1

299 EUR excl. VAT (361,79 EUR Incl. VAT)
Delivery 3-8 days
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote
ADFweb

The ADFweb HD67674-IP-A1 connects BACnet/IP to Modbus TCP. It operates as a BACnet Server and Modbus TCP Server, transferring values through configured BACnet objects and Modbus registers. More

Code: HD67674-IP-A1

ADFweb HD67674-IP-A1

BACnet/IP Server / Modbus TCP Server

The ADFweb HD67674-IP-A1 connects BACnet/IP to Modbus TCP. It operates as a BACnet Server and Modbus TCP Server, transferring values through configured BACnet objects and Modbus registers.

We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.

Request the converter
BACnet/IP Server / Modbus TCP ServerProtocol connection
35 mm DIN railHardware version
SW67674Configuration tool

Converter applications

The converter exposes linked data to a BACnet/IP Client and a Modbus TCP Client. It responds to supervisory systems on both protocols and supports up to 2,000 BACnet objects in total for reading and writing.

Technical specifications HD67674-IP-A1

Order codeHD67674-IP-A1
Protocol connectionBACnet/IP Server / Modbus TCP Server
Converter rolesBACnet/IP Server (Slave); Modbus TCP Server (Slave)
Interfaces and ports2× Ethernet RJ45
BACnet object capacityup to 2,000 in total
Power supply8-24 V AC / 12-35 V DC
Consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)123 × 22.5 × 90.7 mm
Device weightapproximately 200 g
Configuration softwareSW67674

For an older device, check the hardware version and connections against its label.

Communication and configuration

In SW67674, configure BACnet/IP and Modbus TCP. Map register addresses, data types and values to BACnet objects, then upload the configuration over Ethernet.

This model is a Modbus TCP Server, so an external Client must send requests. Choose HD67673-IP-A1 to actively read Modbus TCP Servers.

Supply and accessories

Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.

Documentation and software

Diagrams and hardware version

Dimensional drawing of the version shown - HD67674-IP-A1
Dimensional drawing of the version shown - HD67674-IP-A1

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.

Frequently asked questions

Is knowing the two protocols enough?

The device roles, physical interfaces and data to be transferred must also be checked. This model is a Modbus TCP Server, so an external Client must send requests. Choose HD67673-IP-A1 to actively read Modbus TCP Servers.

How is this converter configured?

In SW67674, configure BACnet/IP and Modbus TCP. Map register addresses, data types and values to BACnet objects, then upload the configuration over Ethernet.

What information should I send to check the selection?

Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.

FOXON support with selection and ordering

Selection based on your devices

We will review the specific connection, communication roles and required data.

Availability check

Before you place an order, we will confirm current availability and the possible delivery date.

Documentation for the exact order code

We select the documentation and configuration tool using the complete order code.

Accessories for your installation

We will include the requested accessories in the quotation to suit the connection arrangement.

Choosing the correct version

Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.

This model is a Modbus TCP Server, so an external Client must send requests. Choose HD67673-IP-A1 to actively read Modbus TCP Servers.

Converter enquiry HD67674-IP-A1

Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.

Request the converter

Technical specifications HD67674-IP-A1

Order codeHD67674-IP-A1
Protocol connectionBACnet/IP Server / Modbus TCP Server
Converter rolesBACnet/IP Server (Slave); Modbus TCP Server (Slave)
Interfaces and ports2× Ethernet RJ45
BACnet object capacityup to 2,000 in total
Power supply8-24 V AC / 12-35 V DC
Consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)123 × 22.5 × 90.7 mm
Device weightapproximately 200 g
Configuration softwareSW67674

For an older device, check the hardware version and connections against its label.