Converter BACnet/IP Server / MQTT - HD67938-IP-B2

Converter BACnet/IP Server / MQTT - HD67938-IP-B2


ADFweb

The ADFweb HD67938-IP-B2 transfers values between BACnet/IP and an MQTT broker. It operates as a BACnet Server and maps values to MQTT publish/subscribe topics. More

Code: HD67938-IP-B2

299 EUR excl. VAT (361,79 EUR Incl. VAT)
Delivery 3-8 days
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote
ADFweb

The ADFweb HD67938-IP-B2 transfers values between BACnet/IP and an MQTT broker. It operates as a BACnet Server and maps values to MQTT publish/subscribe topics. More

Code: HD67938-IP-B2

ADFweb HD67938-IP-B2

BACnet/IP Server / MQTT

The ADFweb HD67938-IP-B2 transfers values between BACnet/IP and an MQTT broker. It operates as a BACnet Server and maps values to MQTT publish/subscribe topics.

We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.

Request the converter
BACnet/IP Server / MQTTProtocol connection
35 mm DIN railHardware version
SW67938Configuration tool

Converter applications

Use it to expose MQTT values to a local BACnet/IP Client and publish BACnet object values to MQTT. The converter itself provides the BACnet objects as a Server.

Technical specifications HD67938-IP-B2

Order codeHD67938-IP-B2
Protocol connectionBACnet/IP Server / MQTT
Converter rolesBACnet/IP Server; MQTT Client
Interfaces and portsEthernet RJ45
Power supplyConfirm against the label and hardware version before ordering
Consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)Confirm for the supplied hardware version
Device weightapproximately 200 g
Configuration softwareSW67938

We will confirm the supply range for this model against the specific hardware version. Always check the device label before connecting the power supply.

Communication and configuration

In SW67938, configure BACnet/IP, transferred objects, the MQTT broker connection and publish/subscribe topics. Data types and value meanings must match both connected systems.

MQTT requires an external broker, and BACnet requires a supervisory Client. This model does not independently poll remote BACnet Servers; use HD67937-IP-B2 for that task. Check required MQTT security for the specific firmware.

Supply and accessories

Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.

Documentation and software

Diagrams and hardware version

Version shown - HD67938-IP-B2
Version shown - HD67938-IP-B2

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.

Frequently asked questions

Is knowing the two protocols enough?

The device roles, physical interfaces and data to be transferred must also be checked. MQTT requires an external broker, and BACnet requires a supervisory Client. This model does not independently poll remote BACnet Servers; use HD67937-IP-B2 for that task. Check required MQTT security for the specific firmware.

How is this converter configured?

In SW67938, configure BACnet/IP, transferred objects, the MQTT broker connection and publish/subscribe topics. Data types and value meanings must match both connected systems.

What information should I send to check the selection?

Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.

FOXON support with selection and ordering

Selection based on your devices

We will review the specific connection, communication roles and required data.

Availability check

Before you place an order, we will confirm current availability and the possible delivery date.

Documentation for the exact order code

We select the documentation and configuration tool using the complete order code.

Accessories for your installation

We will include the requested accessories in the quotation to suit the connection arrangement.

Choosing the correct version

Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.

MQTT requires an external broker, and BACnet requires a supervisory Client. This model does not independently poll remote BACnet Servers; use HD67937-IP-B2 for that task. Check required MQTT security for the specific firmware.

Converter enquiry HD67938-IP-B2

Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.

Request the converter

Technical specifications HD67938-IP-B2

Order codeHD67938-IP-B2
Protocol connectionBACnet/IP Server / MQTT
Converter rolesBACnet/IP Server; MQTT Client
Interfaces and portsEthernet RJ45
Power supplyConfirm against the label and hardware version before ordering
Consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)Confirm for the supplied hardware version
Device weightapproximately 200 g
Configuration softwareSW67938

We will confirm the supply range for this model against the specific hardware version. Always check the device label before connecting the power supply.