Converter PROFINET Master / RS485 - HD67B70-485-A1
Converter PROFINET Master / RS485 - HD67B70-485-A1
The ADFweb HD67B70-485-A1 is an industrial PROFINET Master / RS485 converter. It connects both communication sides through a configured data map. More
Code: HD67B70-485-A1
The ADFweb HD67B70-485-A1 is an industrial PROFINET Master / RS485 converter. It connects both communication sides through a configured data map. More
Code: HD67B70-485-A1
ADFweb HD67B70-485-A1
PROFINET Master / RS485
The ADFweb HD67B70-485-A1 is an industrial PROFINET Master / RS485 converter. It connects both communication sides through a configured data map.
We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.
Converter applications
Connect PROFINET devices to an RS485 serial application. Data is transferred according to the prepared telegram structure and mapping; selection requires the actual serial message format.
Technical specifications HD67B70-485-A1
| Order code | HD67B70-485-A1 |
|---|---|
| Protocol connection | PROFINET Master / RS485 |
| Converter roles | PROFINET Master; Serial RS485 |
| Interfaces | Ethernet RJ45; RS485 |
| Converter data area | 4096 bytes for reading and the same number for writing |
| Converter power supply | 8-24 V AC / 12-35 V DC |
| Consumption at 24 V DC | 4 W |
| Operating temperature | -40 °C to +85 °C |
| Mounting | 35 mm DIN rail |
| Dimensions of the supplied version | To be confirmed for the hardware version before ordering |
| Device weight | approximately 200 g |
| Configuration software | SW67B70 |
For an older device, check the hardware version and connections against its label.
Communication and configuration
Prepare the configuration in SW67B70. Configure the PROFINET installation, RS485 baud rate and parity, serial message composition and data mapping to individual connected modules.
Prepare exact PROFINET device types, their GSDML files, module layouts and input/output data. The converter operates as a PROFINET Master; configure subordinate devices and the data map for the actual installation. We will confirm individual device data sizes and node count for the required configuration.
Supply and accessories
Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.
Documentation and software
Diagrams and hardware version

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.
Frequently asked questions
Is knowing the two protocols enough?
The device roles, physical interfaces and data to be transferred must also be checked. Prepare exact PROFINET device types, their GSDML files, module layouts and input/output data. The converter operates as a PROFINET Master; configure subordinate devices and the data map for the actual installation. We will confirm individual device data sizes and node count for the required configuration.
How is this converter configured?
Prepare the configuration in SW67B70. Configure the PROFINET installation, RS485 baud rate and parity, serial message composition and data mapping to individual connected modules.
What information should I send to check the selection?
Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.
FOXON support with selection and ordering
Selection based on your devices
We will review the specific connection, communication roles and required data.
Availability check
Before you place an order, we will confirm current availability and the possible delivery date.
Documentation for the exact order code
We select the documentation and configuration tool using the complete order code.
Accessories for your installation
We will include the requested accessories in the quotation to suit the connection arrangement.
Choosing the correct version
Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.
Prepare exact PROFINET device types, their GSDML files, module layouts and input/output data. The converter operates as a PROFINET Master; configure subordinate devices and the data map for the actual installation. We will confirm individual device data sizes and node count for the required configuration.
Converter enquiry HD67B70-485-A1
Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.
Request the converterTechnical specifications HD67B70-485-A1
| Order code | HD67B70-485-A1 |
|---|---|
| Protocol connection | PROFINET Master / RS485 |
| Converter roles | PROFINET Master; Serial RS485 |
| Interfaces | Ethernet RJ45; RS485 |
| Converter data area | 4096 bytes for reading and the same number for writing |
| Converter power supply | 8-24 V AC / 12-35 V DC |
| Consumption at 24 V DC | 4 W |
| Operating temperature | -40 °C to +85 °C |
| Mounting | 35 mm DIN rail |
| Dimensions of the supplied version | To be confirmed for the hardware version before ordering |
| Device weight | approximately 200 g |
| Configuration software | SW67B70 |
For an older device, check the hardware version and connections against its label.