The ADFweb HD67814-KNX-B2 connects Modbus TCP Server devices to a KNX TP bus. As a Modbus TCP Client, it actively reads and writes registers and maps their values to KNX telegrams. More
Code: HD67814-KNX-B2
The ADFweb HD67814-KNX-B2 connects Modbus TCP Server devices to a KNX TP bus. As a Modbus TCP Client, it actively reads and writes registers and maps their values to KNX telegrams. More
Code: HD67814-KNX-B2
ADFweb HD67814-KNX-B2
Modbus TCP Client / KNX
The ADFweb HD67814-KNX-B2 connects Modbus TCP Server devices to a KNX TP bus. As a Modbus TCP Client, it actively reads and writes registers and maps their values to KNX telegrams.
We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.
Converter applications
Use it to transfer values from Modbus meters and controllers to a KNX system and write commands in the opposite direction. It supports up to 1,440 bytes for reading and 1,440 bytes for writing.
Technical specifications HD67814-KNX-B2
| Order code | HD67814-KNX-B2 |
|---|---|
| Protocol connection | Modbus TCP Client / KNX |
| Roles and version | Modbus TCP Client; KNX TP |
| Interfaces and ports | KNX TP; Ethernet RJ45 |
| KNX TP data rate | 9 600 bit/s |
| Data capacity | 1440 bytes in each direction |
| Converter power supply | 8-24 V AC / 12-35 V DC |
| Consumption at 24 V DC | 3.5 W |
| Operating temperature | -40 °C to +85 °C |
| Mounting | 35 mm DIN rail |
| Dimensions of the version shown (D × W × H) | 60 × 35 × 95 mm |
| Device weight | approximately 200 g |
| Configuration software | SW67814 |
For an older device, check the hardware version and connections against its label.
Communication and configuration
In SW67814, configure Modbus TCP network parameters, the KNX device address and telegram reception and transmission. Map Modbus registers to KNX group addresses and define the meaning of the transferred data.
Connected devices must operate as Modbus TCP Server units. Configure register addresses, Modbus functions, data types and byte order using their documentation. The converter uses a TP bus on the KNX side. Prepare group addresses, data types and the required transfer direction; check the power supply for both the KNX bus and the converter.
Supply and accessories
Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.
Documentation and software
Diagrams and hardware version

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.
Frequently asked questions
Is knowing the two protocols enough?
The device roles, physical interfaces and data to be transferred must also be checked. Connected devices must operate as Modbus TCP Server units. Configure register addresses, Modbus functions, data types and byte order using their documentation. The converter uses a TP bus on the KNX side. Prepare group addresses, data types and the required transfer direction; check the power supply for both the KNX bus and the converter.
How is this converter configured?
In SW67814, configure Modbus TCP network parameters, the KNX device address and telegram reception and transmission. Map Modbus registers to KNX group addresses and define the meaning of the transferred data.
What information should I send to check the selection?
Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.
FOXON support with selection and ordering
Selection based on your devices
We will review the specific connection, communication roles and required data.
Availability check
Before you place an order, we will confirm current availability and the possible delivery date.
Documentation for the exact order code
We select the documentation and configuration tool using the complete order code.
Accessories for your installation
We will include the requested accessories in the quotation to suit the connection arrangement.
Choosing the correct version
Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.
Connected devices must operate as Modbus TCP Server units. Configure register addresses, Modbus functions, data types and byte order using their documentation. The converter uses a TP bus on the KNX side. Prepare group addresses, data types and the required transfer direction; check the power supply for both the KNX bus and the converter.
Converter enquiry HD67814-KNX-B2
Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.
Request the converterTechnical specifications HD67814-KNX-B2
| Order code | HD67814-KNX-B2 |
|---|---|
| Protocol connection | Modbus TCP Client / KNX |
| Roles and version | Modbus TCP Client; KNX TP |
| Interfaces and ports | KNX TP; Ethernet RJ45 |
| KNX TP data rate | 9 600 bit/s |
| Data capacity | 1440 bytes in each direction |
| Converter power supply | 8-24 V AC / 12-35 V DC |
| Consumption at 24 V DC | 3.5 W |
| Operating temperature | -40 °C to +85 °C |
| Mounting | 35 mm DIN rail |
| Dimensions of the version shown (D × W × H) | 60 × 35 × 95 mm |
| Device weight | approximately 200 g |
| Configuration software | SW67814 |
For an older device, check the hardware version and connections against its label.