from 197,23 EUR Incl. VAT
6GK7243-2AX01-0XA0
- SIEMENS
- SIMATIC S7-200
- Communication modules
- 6GK7243-2AX01-0XA0
6GK7243-2AX01-0XA0
SIEMENS SIMATIC NET CP 243-2 communications processor for connecting SIMATIC S7-22X to AS-Interface networks. More
Code: 6GK7243-2AX01-0XA0
SIEMENS SIMATIC NET CP 243-2 communications processor for connecting SIMATIC S7-22X to AS-Interface networks. More
Code: 6GK7243-2AX01-0XA0
Part Sales 1
| Condition | Code | Warranty | Availability |
Delivery Express? | Price excl. VAT | |
|---|---|---|---|---|---|---|
| Refurbished (R) | 6GK7243-2AX01-0XA0 R | 12/24 months | In external stock 1 pcs |
Within 2-4 days / Express
|
On request
|
Repair of the part
| Name | Code | Delivery | Warranty | Price excl. VAT | |
|---|---|---|---|---|---|
| Complete part repair | 6GK7243-2AX01-0XA0 O | 3-6 weeks | 24 months | On request | Enquire a repair |
6GK7243-2AX01-0XA0 – CP 243-2
CP 243-2.
Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.
Application and selection
Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.
Technical specifications
| Manufacturer | Siemens |
|---|---|
| Order number | 6GK7243-2AX01-0XA0 |
| General technical data / product designation | AS-Interface Master |
| General technical data / product type designation | CP 243-2 |
| General technical data / protection class IP | IP20 |
| General technical data / type of electrical connection of the AS-Interface | Screw-type connection |
| General technical data / type of voltage supply | via backplane bus |
| General technical data / consumed current / from profile conductors of the AS-Interface / at 30 V maximum | mA 100 |
| General technical data / consumed current / from backplane bus maximum | mA 220 |
| General technical data / power loss [W] | W 3.7 |
| General technical data / insulation voltage rated value | V 500 |
| General technical data / product feature redundancy capability | No |
| General technical data / product function suitable for AS-i Power24V | No |
| General technical data / product function / web-based management | No |
| General technical data / product function / diagnostics via email | No |
| General technical data / product function / galvanic isolation | Yes |
| General technical data / display version / as status display by LED | PWR, APF, CER, AUP, CM, SF |
| General technical data / type of configuration of the AS-Interface | Set pushbutton on device, command interface |
| Communication/ Protocol / version of the AS-Interface specification | V 2.11 |
| Communication/ Protocol / AS-Interface master profile is supported | M3 (in acc. with AS-interface specification V 2.1) |
| Communication/ Protocol / type of data transmission | S7-200 backplane bus |
| Communication/ Protocol / number of units per CPU maximum | 2 |
| Communication/ Protocol / number of interfaces / as AS-Interface | 1 |
| Communication/ Protocol / number of interfaces / according to RS 485 | 0 |
| Communication/ Protocol / number of interfaces / according to Industrial Ethernet | 0 |
| Communication/ Protocol / number of interfaces / according to PROFINET | 0 |
| Communication/ Protocol / number of interfaces / according to wireless | 0 |
| Communication/ Protocol / number of interfaces / according to USB | 0 |
| Communication/ Protocol / number of interfaces / other | 0 |
| Communication/ Protocol / product component optical interface | No |
| Communication/ Protocol / protocol is supported / ASIsafe (Safety at work) protocol | No |
| Communication/ Protocol / protocol is supported / PROFIsafe protocol | No |
| Communication/ Protocol / protocol is supported / PROFIBUS protocol | No |
| Communication/ Protocol / protocol is supported / PROFINET IO protocol | No |
| Communication/ Protocol / protocol is supported / PROFINET CBA protocol | No |
| Communication/ Protocol / protocol is supported / TCP/IP | No |
| Communication/ Protocol / protocol is supported / SNMP | No |
| Communication/ Protocol / standard for wireless communication IEEE 802.11 | No |
| Inputs/ Outputs / number of inputs for AS-Interface maximum | 248 |
| Inputs/ Outputs / number of outputs for AS-Interface maximum | 186 |
| Inputs/ Outputs / number of AS-i devices per AS-Interface maximum | 62 |
| Inputs/ Outputs / bus cycle time of the AS-Interface / for 31 devices | ms 5 |
| Inputs/ Outputs / bus cycle time of the AS-Interface / for 62 devices | ms 10 |
| Inputs/ Outputs / access to digital I/O data | via process image/peripheral addresses |
| Inputs/ Outputs / access to analog I/O data | via process image/peripheral addresses |
| Mechanical data / width | mm 71 |
| Mechanical data / height | mm 80 |
| Mechanical data / depth | mm 62 |
| Mechanical data / fastening method | snap-on fastening on 35 mm DIN rail or screw fastening using an additional push-in lug |
| Mechanical data / module format | S7-200 modular system |
| Ambient conditions / ambient temperature / if installed on horizontal mounting rail during operation | °C 0 ... 55 |
| Ambient conditions / ambient temperature / if installed on vertical mounting rail during operation | °C 0 ... 45 |
| Ambient conditions / ambient temperature / during transport | °C -40 ... +70 |
| Ambient conditions / ambient temperature / during storage | °C -40 ... +70 |
| Ambient conditions / relative humidity at 25 °C during operation maximum | % 95 |
| Ambient conditions / installation altitude at height above sea level maximum | m 2 000 |
| Safety related data / suitability for use safety-related function | No |
| Safety related data / equipment / EEx ia | No |
| Safety related data / equipment / EEx ib | No |
| Safety related data / explosion protection category for gas | II 3 G Ex nA IIC T4 Gc |
| Safety related data / explosion protection category for dust | none |
| Product description | SIMATIC NET |
Connections and conditions of use
- General technical data / type of electrical connection of the AS-Interface: Screw-type connection
- General technical data / type of voltage supply: via backplane bus
- General technical data / consumed current / from profile conductors of the AS-Interface / at 30 V maximum: mA 100
- General technical data / consumed current / from backplane bus maximum: mA 220
- General technical data / insulation voltage rated value: V 500
- General technical data / type of configuration of the AS-Interface: Set pushbutton on device, command interface
- Communication/ Protocol / version of the AS-Interface specification: V 2.11
- Communication/ Protocol / AS-Interface master profile is supported: M3 (in acc. with AS-interface specification V 2.1)
Scope of supply
We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.
Frequently asked questions
Is the same product family enough to identify a replacement?
The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.
What information is needed to check connections and accessories?
Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.
Can you assess a faulty part?
Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.
Why buy from FOXON
Replacement part availability
We will check current part availability and confirm the possible delivery date before you order.
New original and refurbished parts
We will specify the available version and condition of the particular unit in the quotation.
Parts with a warranty
We will confirm the warranty period according to the part condition and specific quotation.
Diagnostics and repairs
For a faulty unit, we will check the options for diagnostics and professional repair.
Part conditions available for sale
Part conditions and warranty
- New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
- New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
- New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
- New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
- Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
- Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
- Used (U): Functional used part. 3-month warranty.


Sales, repairs and buyback of automation parts
We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.
Need to buy or repair this part?
Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.
Request a quote for purchase or repairHighlighted items are mandatory.