from 370,26 EUR Incl. VAT
6ES7414-2XG04-0AB0
- SIEMENS
- SIMATIC S7-400
- CPU
- 6ES7414-2XG04-0AB0
6ES7414-2XG04-0AB0
SIMATIC S7-400, CPU 414-2 Central processing unit with: Work memory 512 KB, (256 KB code, 256 KB data), 1st interface MPI/DP 12 Mbit/s, 2nd interface PROFIBUS DP More
Code: 6ES7414-2XG04-0AB0
SIMATIC S7-400, CPU 414-2 Central processing unit with: Work memory 512 KB, (256 KB code, 256 KB data), 1st interface MPI/DP 12 Mbit/s, 2nd interface PROFIBUS DP More
Code: 6ES7414-2XG04-0AB0
Part Sales 1
| Condition | Code | Warranty | Availability |
Delivery Express? | Price excl. VAT | |
|---|---|---|---|---|---|---|
| Refurbished (R) | 6ES7414-2XG04-0AB0 R | 12/24 months | In external stock 4 pcs |
Within 2-4 days / Express
|
On request
|
Repair of the part
| Name | Code | Delivery | Warranty | Price excl. VAT | |
|---|---|---|---|---|---|
| Complete part repair | 6ES7414-2XG04-0AB0 O | 3-6 weeks | 24 months | On request | Enquire a repair |
6ES7414-2XG04-0AB0 – CPU 414-2
SIMATIC S7-400, CPU 414-2 central processing unit.
Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.
CPU application
The CPU executes the user program and handles SIMATIC S7-400 communication. Before replacement, check the complete order number, actual firmware version, memory card and interface configuration in the original project.
Technical specifications
| Manufacturer | Siemens |
|---|---|
| Order number | 6ES7414-2XG04-0AB0 |
| Product type | CPU 414-2 |
| Firmware version covered by these specifications | V 4.0 |
| Product status / associated programming package | STEP7 V 5.2 SP1 or higher HF3 with HW-update |
| Voltages and currents / Feeding of external buffer voltage to CPU | 5 to 15 V DC |
| Current consumption / from backplane bus DC 5 V, max. | 1.2 A |
| Current consumption / Power loss, typ. | 4.5 W |
| Backup battery / Buffer current, typ. | 550 µA |
| Backup battery / Buffer current, max. | 1,530 µA |
| Memory / RAM / integrated (for program) | 256 KByte |
| Memory / RAM / integrated (for data) | 256 KByte |
| Memory / RAM / expandable | No |
| Memory / Load memory / expandable FEPROM | Yes; with Memory card (FLASH) |
| Memory / Load memory / expandable FEPROM, max. | 64 MByte |
| Memory / Load memory / integrated RAM, max. | 256 KByte |
| Memory / Load memory / expandable RAM | Yes; with Memory Card (RAM) |
| Memory / Backup / present | Yes |
| Memory / Backup / with battery | Yes; all data |
| Memory / Backup / without battery | No |
| CPU/blocks / DB / Size, max. | 64 KByte |
| CPU/blocks / FB / Number, max. | 2,048 |
| CPU/blocks / FB / Size, max. | 64 KByte |
| CPU/blocks / FC / Number, max. | 2,048 |
| CPU/blocks / FC / Size, max. | 64 KByte |
| CPU/blocks / OB / Size, max. | 64 KByte |
| CPU/blocks / Nesting depth / per priority class | 24 |
| CPU/blocks / Nesting depth / additional within an error OB | 1 |
| CPU/processing times / for bit operations, min. | 0.06 µs |
| CPU/processing times / for word operations, min. | 0.06 µs |
| CPU/processing times / for fixed point arithmetic, min. | 0.06 µs |
| CPU/processing times / for floating point arithmetic, min. | 0.18 µs |
| Times/counters and their remanence / S7 counter / Number | 2,048 |
| Times/counters and their remanence / S7 counter / Remanence / adjustable | Yes |
| Times/counters and their remanence / S7 counter / Remanence / lower limit | 0 |
| Times/counters and their remanence / S7 counter / Remanence / upper limit | 2,047 |
| Times/counters and their remanence / S7 counter / Remanence / preset | From Z 0 to Z 7 |
| Times/counters and their remanence / S7 counter / Counting range / lower limit | 0 |
| Times/counters and their remanence / S7 counter / Counting range / upper limit | 999 |
| Times/counters and their remanence / IEC counter / present | Yes |
| Times/counters and their remanence / IEC counter / Type | SFB |
| Times/counters and their remanence / S7 times / Number | 2,048 |
| Times/counters and their remanence / S7 times / Remanence / adjustable | Yes |
| Times/counters and their remanence / S7 times / Remanence / lower limit | 0 |
| Times/counters and their remanence / S7 times / Remanence / upper limit | 2,047 |
| Times/counters and their remanence / S7 times / Remanence / preset | no timers retentive |
| Times/counters and their remanence / S7 times / Time range / lower limit | 10 ms |
| Times/counters and their remanence / S7 times / Time range / upper limit | 9,990 s |
| Times/counters and their remanence / IEC timer / present | Yes |
| Times/counters and their remanence / IEC timer / Type | SFB |
| Data areas and their remanence / remanent data area, total | total working and load memory (with backup battery) |
| Data areas and their remanence / Flag / Number, max. | 8 KByte |
| Data areas and their remanence / Flag / Remanence available | Yes; from MB 0 to MB 8191 |
| Data areas and their remanence / Flag / Number of clock memories | 8; (1 memory byte) |
| Address area / I/O address area / Inputs | 8 KByte |
| Address area / I/O address area / Outputs | 8 KByte |
| Address area / I/O address area / of which, distributed / MPI/DPinterface, inputs | 2 KByte |
| Address area / I/O address area / of which, distributed / MPI/DP interface, outputs | 2 KByte |
| Address area / I/O address area / of which, distributed / DP interface, inputs | 6 KByte; (For each line that is operated in isochronous mode, i.e. to which an OB 61 to 62 has been assigned, the distributed IO address areas are halved) |
| Address area / I/O address area / of which, distributed / DP interface, outputs | 6 KByte; (For each line that is operated in isochronous mode, i.e. to which an OB 61 to 62 has been assigned, the distributed IO address areas are halved) |
| Address area / Process image / Inputs, adjustable | 8 KByte |
| Address area / Process image / Outputs, adjustable | 8 KByte |
| Address area / Process image / Inputs, preset | 256 Byte |
| Address area / Process image / Outputs, preset | 256 Byte |
| Address area / Process image / consistent data, max. | 244 Byte |
| Address area / Process image / Access to consistent data in process image | Yes |
| Address area / Subprocess images / Number of subprocess images, max. | 15 |
| Address area / Digital channels / Inputs | 65,536 |
| Address area / Digital channels / Outputs | 65,536 |
| Address area / Digital channels / Inputs, of which central | 65,536 |
| Address area / Digital channels / Outputs, of which central | 65,536 |
| Address area / Analog channels / Inputs | 4,096 |
| Address area / Analog channels / Outputs | 4,096 |
| Address area / Analog channels / Inputs, of which central | 4,096 |
| Address area / Analog channels / Outputs, of which central | 4,096 |
| Hardware config. / connectable OPs | 31 without message processing, 8 with message processing |
| Hardware config. / Central devices, max. | 1 |
| Hardware config. / Expansion devices, max. | 21; (of which 6 ER with K-bus) |
| Hardware config. / Multicomputing | Yes; max. 4 CPUs (with UR1 or UR2) |
| IM / Number of connectable IMs (total), max. | 6 |
| IM / Number of connectable IM 460s, max. | 6 |
| IM / Number of connectable IM 463s, max. | 4; IM 463-2 |
| Number of DP masters / integrated | 2 |
| Number of DP masters / via IM 467 | 4 |
| Number of DP masters / via CP | 10; CP 443-5 Ext. |
| Number of DP masters / Mixed mode IM + CP permitted | No; IM467 cannot be used jointly with CP 443-5 Ext. |
| Number of DP masters / via interface module | 0 |
| Number of DP masters / Number of pluggable S5 modules (via adapter capsule in central device), max. | 6 |
| Number of operable FMs and CPs (recommended) / PROFIBUS and Ethernet CPs | 14; incl. CP 443-5 Ext. and IM 467 |
| Time / Clock / Hardware clock (real-time clock) | Yes |
| Time / Clock / Battery backed and synchronized | Yes |
| Time / Clock / Resolution | 1 ms |
| Time / Operating hours counter / Number | 8 |
| Time / Clock synchronization / supports | Yes |
| Time / Clock synchronization / to MPI, Master | Yes |
| Time / Clock synchronization / to MPI, Slave | Yes |
| Time / Clock synchronization / to DP, Master | Yes |
| Time / Clock synchronization / to DP, Slave | Yes |
| Time / Clock synchronization / to PN via NTP as client | No |
| Time / Clock synchronization / in AS, Master | Yes |
| Time / Clock synchronization / in AS, Slave | Yes |
| S7 message functions / Number of login stations for message functions, max. | 8 |
| S7 message functions / Symbol-related messages | Yes |
| S7 message functions / Number of messages / overall, max. | 512 |
| S7 message functions / Block related messages | Yes |
| S7 message functions / Alarm 8-blocks | Yes |
| S7 message functions / Instrumentation & control messages | Yes |
| Test commissioning functions / Status/control / Status/control variable | Yes |
| Monitoring functions / Forcing | Yes |
| Monitoring functions / Status block | Yes |
| Monitoring functions / Single step | Yes |
| Monitoring functions / Number of breakpoints | 4 |
| Monitoring functions / Diagnostic buffer / present | Yes |
| Monitoring functions / Diagnostic buffer / Number of entries, max. | 400 |
| Monitoring functions / Diagnostic buffer / adjustable | Yes |
| Monitoring functions / Diagnostic buffer / preset | 120 |
| Communication functions / PG/OP communication | Yes |
| Communication functions / Routing | Yes |
| Communication functions / Global data communication / supported | Yes |
| Communication functions / Global data communication / Size of GD packets, max. | 64 Byte |
| Communication functions / S7 basic communication / supported | Yes; in MPI mode: via SFC X_SEND, X_RCV, X_GET and X_PUT; in DP master mode: via SFC I_GET and I_PUT |
| Communication functions / S7 basic communication / Useful data per job, max. | 76 Byte |
| Communication functions / S7 communication / supported | Yes |
| Communication functions / S7 communication / as server | Yes |
| Communication functions / S7 communication / as client | Yes |
| Communication functions / S7 communication / Useful data per job, max. | 64 KByte |
| Communication functions / S5-compatible communication / supported | Yes; via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5 |
| Communication functions / S5-compatible communication / Useful data per job, max. | 8 KByte |
| Communication functions / Standard communication (FMS) / supported | Yes; via CP and loadable FB |
| Communication functions / Number of connections / overall | 32 |
| 1st interface / Physics | RS 485/PROFIBUS |
| 1st interface / isolated | Yes |
| 1st interface / Functionality / MPI | Yes |
| 1st interface / Functionality / DP master | Yes |
| 1st interface / Functionality / DP slave | Yes |
| MPI / Number of connections | 32 |
| MPI / Services / PG/OP communication | Yes |
| MPI / Services / Routing | Yes |
| MPI / Services / Global data communication | Yes |
| MPI / Services / S7 basic communication | Yes |
| MPI / Services / S7 communication | Yes |
| MPI / Transmission speeds, max. | 12 Mbit/s |
| DP master / Number of connections, max. | 16 |
| DP master / Services / PG/OP communication | Yes |
| DP master / Services / Routing | Yes |
| DP master / Services / S7 basic communication | Yes |
| DP master / Services / S7 communication | Yes |
| DP master / Services / equidistance support | Yes |
| DP master / Services / Activation/deactivation of DP slaves | Yes |
| DP master / Services / direct data exchange (cross traffic) | Yes |
| DP master / Transmission speeds, max. | 12 Mbit/s |
| DP master / Useful data per DP slave / Inputs, max. | 244 Byte |
| DP master / Useful data per DP slave / Outputs, max. | 244 Byte |
| DP slave / Number of connections | 16 |
| DP slave / Services / Routing | Yes |
| DP slave / Services / Status/control | Yes |
| DP slave / Services / Programming | Yes |
| DP slave / Transmission speeds, max. | 12 Mbit/s |
| DP slave / Transfer memory / Inputs | 244 Byte |
| DP slave / Transfer memory / Outputs | 244 Byte |
| DP slave / Address area, max. | 32 |
| DP slave / Useful data per address area, max. | 32 Byte |
| DP slave / Useful data per address area, of which consistent, max. | 32 Byte |
| 2nd interface / Type of interface | integrated |
| 2nd interface / Physics | RS 485/PROFIBUS |
| 2nd interface / Isolated | Yes |
| Functionality / PROFINET | No |
| Functionality / MPI | Yes |
| Functionality / PROFIBUS DP | No |
| Functionality / Point-to-point coupling | No |
| Functionality / DP slave | Yes |
| Functionality / DP master | Yes |
| DP master / Services | Yes |
| DP master / PG/OP communication | Yes |
| DP master / Routing | Yes |
| DP master / S7 basic communication | Yes |
| DP master / S7 communication | Yes |
| DP master / equidistance support | Yes |
| DP master / Activation/deactivation of DP slaves | Yes |
| DP master / direct data exchange (cross traffic) | Yes |
| 2nd interface / Useful data per DP slave / Inputs, max. | 244 Byte |
| 2nd interface / Useful data per DP slave / Outputs, max. | 244 Byte |
| 2nd interface / DP slave / Services / Routing | Yes |
| 2nd interface / DP slave / Services / Status/control | Yes |
| 2nd interface / DP slave / Services / Programming | Yes |
| 2nd interface / DP slave / Transmission speeds, max. | 12 Mbit/s |
| 2nd interface / DP slave / Transfer memory / Inputs | 244 Byte |
| 2nd interface / DP slave / Transfer memory / Outputs | 244 Byte |
| 2nd interface / DP slave / Address area, max. | 32 |
| 2nd interface / DP slave / Useful data per address area, max. | 32 Byte |
| 2nd interface / DP slave / Useful data per address area, of which consistent, max. | 32 Byte |
| Isochronous mode / Useful data per isochronous slave, max. | 244 Byte |
| Isochronous mode / equidistance | Yes |
| Isochronous mode / shortest clock pulse | 1 ms |
| CiR configuration in RUN / CiR synchronization time, basic load | 100 ms |
| CiR configuration in RUN / CiR synchronization time, time per I/O slave | 80 µs |
| CPU/programming / Programming language / STEP 7 | Yes |
| CPU/programming / Programming language / LAD | Yes |
| CPU/programming / Programming language / FUP | Yes |
| CPU/programming / Programming language / AWL | Yes |
| CPU/programming / Programming language / SCL | Yes |
| CPU/programming / Programming language / CFC | Yes |
| CPU/programming / Programming language / HiGraph | Yes |
| CPU/programming / Nesting levels | 8 |
| CPU/programming / User program protection/password protection | Yes |
| Dimensions and weight / Width | 25 mm |
| Dimensions and weight / Height | 290 mm |
| Dimensions and weight / Depth | 219 mm |
| Dimensions and weight / Required slots | 1 |
| Weights / Weight, approx. | 720 g |
Communication and configuration
- Firmware version covered by these specifications: V 4.0
- Product status / associated programming package: STEP7 V 5.2 SP1 or higher HF3 with HW-update
- Memory / Load memory / expandable FEPROM: Yes; with Memory card (FLASH)
- Memory / Load memory / expandable FEPROM, max.: 64 MByte
- Memory / Load memory / integrated RAM, max.: 256 KByte
- Memory / Load memory / expandable RAM: Yes; with Memory Card (RAM)
- Address area / I/O address area / of which, distributed / MPI/DPinterface, inputs: 2 KByte
- Address area / I/O address area / of which, distributed / MPI/DP interface, outputs: 2 KByte
Scope of supply
We will confirm the specific scope of supply, packaging and any accessories in the quotation. For replacement CPUs, we will also check the memory card and other items needed for commissioning.
Frequently asked questions
Is the same product family enough to identify a replacement?
The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.
What must be checked for firmware and a STEP 7 or TIA Portal project?
Check the replacement unit's actual firmware and the availability of this exact CPU in the hardware catalog of your engineering version. TIA Portal support cannot be confirmed from the product family name alone. A change of CPU type normally requires modification or at least a thorough check of the project.
Does the memory card need to be checked?
Yes. Check the memory card type and capacity, program and data contents and the original CPU's backup arrangement. We will specify the required card and accessories in the quotation.
Can you assess a faulty part?
Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.
Why buy from FOXON
Replacement part availability
We will check current part availability and confirm the possible delivery date before you order.
New original and refurbished parts
We will specify the available version and condition of the particular unit in the quotation.
Parts with a warranty
We will confirm the warranty period according to the part condition and specific quotation.
Diagnostics and repairs
For a faulty unit, we will check the options for diagnostics and professional repair.
Part conditions available for sale
Part conditions and warranty
- New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
- New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
- New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
- New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
- Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
- Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
- Used (U): Functional used part. 3-month warranty.


Sales, repairs and buyback of automation parts
We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.
Need to buy or repair this part?
Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.
Request a quote for purchase or repairHighlighted items are mandatory.