6ES7317-6TJ10-0AB0

6ES7317-6TJ10-0AB0

Sales, Repair, Purchase

SIEMENS

SIMATIC S7-300, CPU 317T-2 DP, central processing unit for PLC and technology 512 kByte working memory, 1. interface MPI/DP 12mbit/s 2. interface DP(drive), integrated I/O for technology front connector (1 x 40pin) and micro memory card min. 4MB necessary More

Code: 6ES7317-6TJ10-0AB0

Variant does not exist

Rezervace termínu

Get a quote
SIEMENS

SIMATIC S7-300, CPU 317T-2 DP, central processing unit for PLC and technology 512 kByte working memory, 1. interface MPI/DP 12mbit/s 2. interface DP(drive), integrated I/O for technology front connector (1 x 40pin) and micro memory card min. 4MB necessary More

Code: 6ES7317-6TJ10-0AB0

Repair of the part

Name Code Delivery Warranty Price excl. VAT
Complete part repair 6ES7317-6TJ10-0AB0 O 3-6 weeks 24 months On request Enquire a repair

6ES7317-6TJ10-0AB0 – CPU 317T-2 DP

Siemens SIMATIC S7-300 CPU 317T-2 DP.

Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.

Request a quote for purchase or repair
512 KByteMemory / RAM / integrated
RS 4851st interface / Physics
RS 4852nd interface / Physics

CPU application

The CPU executes the user program and handles SIMATIC S7-300 communication. Before replacement, check the complete order number, actual firmware version, memory card and interface configuration in the original project.

Technical specifications

ManufacturerSiemens
Order number6ES7317-6TJ10-0AB0
Product type designationCPU 317T-2 DP
Product status / associated programming packageSTEP 7 V5.2 or higher + SP 1 + HF 1 and option package S7- Technology
Supply voltages / Rated value / DC 24 VYes
Supply voltages / Rated value / permissible range, lower limit (DC)20.4 V
Supply voltages / Rated value / permissible range, upper limit (DC)28.8 V
Voltages and currents / external protection for supply cables (recommendation)min. 2 A
Current consumption / Inrush current, max.2,5 A
Current consumption / I²t1 A²s
Current consumption / Current consumption (in no-load operation), typ.200 mA
Current consumption / Power loss, typ.6 W
Memory / RAM / integrated512 KByte
Memory / RAM / expandableNo
Memory / Load memory / pluggable (MMC)Yes; min. 4 MB required
Memory / Load memory / pluggable (MMC), max.8 MByte
Backup / presentYes; guaranteed by MMC (maintenance- free)
CPU/blocks / DB / Number, max.2,047; DB 0 reserved
CPU/blocks / DB / Size, max.64 KByte
CPU/blocks / FB / Number, max.2,048; See Operation List
CPU/blocks / FB / Size, max.64 KByte
CPU/blocks / FC / Number, max.2,048; See Operation List
CPU/blocks / FC / Size, max.64 KByte
CPU/blocks / OB / Size, max.64 KByte
CPU/blocks / Nesting depth / per priority class16
CPU/blocks / Nesting depth / additional within an error OB4
CPU/processing times / for bit operations, min.0.05 µs
CPU/processing times / for word operations, min.0.2 µs
CPU/processing times / for fixed point arithmetic, min.0.2 µs
CPU/processing times / for floating point arithmetic, min.1 µs
Times/counters and their remanence / S7 counter / Number512
Times/counters and their remanence / S7 counter / of which remanent without battery / adjustableYes
Times/counters and their remanence / S7 counter / Counting range / adjustableYes
Times/counters and their remanence / S7 counter / Counting range / lower limit0
Times/counters and their remanence / S7 counter / Counting range / upper limit999
Times/counters and their remanence / IEC counter / presentYes
Times/counters and their remanence / IEC counter / TypeSFB
Times/counters and their remanence / S7 times / Number512
Times/counters and their remanence / S7 times / Remanence / adjustableYes
Times/counters and their remanence / S7 times / Remanence / presetNo retentivity
Time range / lower limit10 ms
Time range / upper limit9,990 s
IEC timer / presentYes
IEC timer / TypeSFB
Data areas and their remanence / Flag / Number, max.4,096 Byte
Data areas and their remanence / Flag / Remanence availableYes; MB 0 to MB 4095
Data areas and their remanence / Flag / Number of clock memories8; 1 memory byte
Data areas and their remanence / Data blocks / Number, max.2,047; DB 0 reserved
Data areas and their remanence / Data blocks / Size, max.64 KByte
Data areas and their remanence / Data blocks / Remanence adjustableYes
Data areas and their remanence / Local data / per priority class, max.1,024 Byte
Address area / I/O address area / Inputs8 KByte
Address area / I/O address area / Outputs8 KByte
Address area / I/O address area / of which, distributed / Inputs8 KByte
Address area / I/O address area / of which, distributed / Outputs8 KByte
Address area / Process image / Inputs256 Byte
Address area / Process image / Outputs256 Byte
Address area / Digital channels / Inputs65,636
Address area / Digital channels / Outputs65,636
Address area / Digital channels / Inputs, of which central256
Address area / Digital channels / Outputs, of which central256
Address area / Analog channels / Inputs4,096
Address area / Analog channels / Outputs4,096
Address area / Analog channels / Inputs, of which central64
Address area / Analog channels / Outputs, of which central64
Hardware config. / Racks, max.1
Hardware config. / Modules per rack, max.8
Number of DP masters / integrated2
Number of DP masters / via CP2
Number of operable FMs and CPs (recommended) / FM8
Number of operable FMs and CPs (recommended) / CP, point-to-point8
Number of operable FMs and CPs (recommended) / CP, LAN10
Time / Clock / Hardware clock (real-time clock)Yes
Time / Clock / Battery backed and synchronizedYes
Time / Clock / Deviation per day, max.10 s
Time / Operating hours counter / Number4
Time / Operating hours counter / Number/ Number range0 bis 3
Time / Operating hours counter / Range of values0 to 2^31 hours (when using SFC101)
Time / Operating hours counter / Granularity1 hour
Time / Operating hours counter / remanentYes; must be restarted at each warm restart
Time / Clock synchronization / supportsYes
Time / Clock synchronization / to MPI, MasterYes
Time / Clock synchronization / to MPI, SlaveYes
Time / Clock synchronization / in AS, MasterYes
Time / Clock synchronization / in AS, SlaveYes
S7 message functions / Number of login stations for message functions, max.32; depending on the configured connections for PG/OP and S7 basic communication
S7 message functions / Process diagnostic messagesYes
S7 message functions / Simultaneously active Alarm-S blocks, max.60
Test commissioning functions / Status/control / Status/control variableYes
Test commissioning functions / Status/control / VariablesInputs, outputs, memory bits, DB, times, counters
Monitoring functions / Number of variables, max.30
Monitoring functions / of which status variable, max.30
Monitoring functions / of which control variable, max.14
Monitoring functions / ForcingYes
Monitoring functions / Forcing / Force, variablesInputs, outputs
Monitoring functions / Forcing / Forcing, number of variables, max.10
Monitoring functions / Status blockYes
Monitoring functions / Single stepYes
Monitoring functions / Number of breakpoints2
Monitoring functions / Diagnostic buffer / presentYes
Monitoring functions / Diagnostic buffer / Number of entries, max.100
Monitoring functions / Diagnostic buffer / adjustableNo
Communication functions / PG/OP communicationYes
Communication functions / RoutingYes
Communication functions / Global data communication / supportedYes
Communication functions / Global data communication / Size of GD packets, max.22 Byte
Communication functions / S7 basic communication / supportedYes
Communication functions / S7 communication / supportedYes
Communication functions / S5-compatible communication / supportedYes; via CP and loadable FC
Communication functions / Number of connections / overall32
Communication functions / Number of connections / usable for PG communication31
Communication functions / Number of connections / usable for OP communication31
Communication functions / Number of connections / usable for S7 basic communication30
1st interface / Type of interfaceIntegral RS 485 interface
1st interface / PhysicsRS 485
1st interface / isolatedYes
Power supply to interface (15 to 30 V DC), max.200 mA
Functionality / MPIYes
Functionality / DP masterYes
Functionality / DP slaveYes
Functionality / Point-to-point couplingNo
MPI / Services / PG/OP communicationYes
MPI / Services / RoutingYes
MPI / Services / Global data communicationYes
MPI / Services / S7 basic communicationYes
MPI / Services / S7 communicationYes
MPI / Services / S7 communication, as clientYes; via CP and loadable FB
MPI / Services / S7 communication, as serverYes
MPI / Transmission speeds, max.12 Mbit/s
DP-Master / Services / PG/OP communicationYes
DP-Master / Services / RoutingYes
DP-Master / Services / Global data communicationNo
DP-Master / Services / S7 basic communicationNo
DP-Master / Services / S7 communicationNo
DP-Master / Services / equidistance supportYes
DP-Master / Services / SYNC/FREEZEYes
DP-Master / Services / DPV1Yes
DP-Master / Transmission speeds, max.12 Mbit/s
DP-Master / Number of DP slaves, max.124
DP-Master / Address area / Inputs, max.244 KByte
DP-Master / Address area / Outputs, max.244 KByte
DP slave / Services / RoutingYes
DP slave / Services / Global data communicationNo
DP slave / Services / S7 basic communicationNo
DP slave / Services / S7 communicationNo
DP slave / Services / direct data exchange (cross traffic)Yes
DP slave / Services / DPV1No
DP slave / Transmission speeds, max.12 Mbit/s
DP slave / Transfer memory / Inputs244 Byte
DP slave / Transfer memory / Outputs244 Byte
DP slave / Address area, max.32
DP slave / Useful data per address area, max.32 Byte
2nd interface / Type of interfaceIntegral RS 485 interface
2nd interface / PhysicsRS 485
2nd interface / isolatedYes
2nd interface / Power supply to interface (15 to 30 V DC), max.200 mA
2nd interface / Functionality / MPINo
2nd interface / Functionality / DP masterYes; DP(DRIVE)-Master
2nd interface / Functionality / DP slaveNo
2nd interface / Functionality / Point-to-point couplingNo
2nd interface / DP master / Services / PG/OP communicationNo
2nd interface / DP master / Services / RoutingNo
2nd interface / DP master / Services / Global data communicationNo
2nd interface / DP master / Services / S7 basic communicationNo
2nd interface / DP master / Services / S7 communicationNo
2nd interface / DP master / Services / equidistance supportYes
2nd interface / DP master / Services / SYNC/FREEZENo
2nd interface / DP master / Services / Activation/ deactivation of DP slavesNo
2nd interface / DP master / Services / DPV1No
DP-Master (continued) / Transmission speeds, max.12 Mbit/s
DP-Master (continued) / Number of DP slaves, max.32
DP-Master (continued) / Address area / Inputs, max.244 KByte
DP-Master (continued) / Address area / Outputs, max.244 KByte
CPU/programming / Configuration software / STEP 7Yes
CPU/programming / Programming language / STEP 7Yes; V 5.2 SP 1 or higher and S7-Technology option package
CPU/programming / Programming language / LADYes
CPU/programming / Programming language / FUPYes
CPU/programming / Programming language / AWLYes
CPU/programming / Programming language / SCLYes
CPU/programming / Programming language / CFCYes
CPU/programming / Programming language / GRAPHYes
CPU/programming / Programming language / HiGraphYes
CPU/programming / Operational stocksSee Operation List
CPU/programming / Nesting levels8
CPU/programming / User program protection/password protectionYes
CPU/programming / System functions (SFC)See Operation List
CPU/programming / System function blocks (SFB)See Operation List
Digital inputs / Number of digital inputs4
Digital inputs / Functionstechnological functions, e.g. reference point recording (BERO), digital inputs can also be used (with restrictions) in STEP 7 user program.
Digital inputs / Number of simultaneously controllable inputs / Number of simultaneously controllable inputs, up to 40 °C4
Digital inputs / Number of simultaneously controllable inputs / Number of simultaneously controllable inputs, up to 60 °C4
Cable length / Cable length, shielded, max.1,000 m
Cable length / Cable length unshielded, max.600 m
Input characteristic curve to IEC 1131, Typ 1Yes
Input voltage / Rated value, DC24 V
Input voltage / for signal "0"3 to 5 V
Input voltage / for signal "1"15 to 30 V
Input current / for signal "1", typ.7 mA
Input delay (for rated value of input voltage) / for counter/technological functions / at "0" to "1", max.10 µs; typically
Input delay (for rated value of input voltage) / for counter/technological functions / at "1" to "0", max.10 µs; typically
Digital outputs / Number of digital outputs8
Digital outputs / Functionsfor technological functions, e.g. fast cam switching signals
Digital outputs / Cable length, shielded, max.1,000 m
Digital outputs / Cable length unshielded, max.600 m
Digital outputs / Short-circuit protection of the outputYes
Digital outputs / Response threshold, typ.1.0 A
Digital outputs / Limitation of inductive shutdown voltage to2L+ (-48 V)
Digital outputs / Lamp load, max.5 W
Digital outputs / Controlling a digital inputNo
Digital outputs / Output voltage / for signal "0" (DC), max.3 V
Digital outputs / Output voltage / for signal "1", min.2L+ (-2.5 V)
Output current / for signal "1" rated value0.5 A
Output current / for signal "1" permissible range for 0 to 60 °C, min.5 mA
Output current / for signal "1" permissible range for 0 to 60 °C, max.0.6 A
Output current / for signal "0" residual current, max.0.3 mA
Parallel switching of 2 outputs / for increased powerNo
Parallel switching of 2 outputs / for redundant control of a loadNo
Switching frequency / with resistive load, max.100 Hz
Switching frequency / with inductive load, max.0.2 Hz; to IEC 947-5-1, DC13
Switching frequency / on lamp load, max.100 Hz
Aggregate current of the outputs (per group) / horizontal installation / up to 40 °C, max.4 A
Aggregate current of the outputs (per group) / horizontal installation / up to 60 °C, max.3 mA
Aggregate current of the outputs (per group) / all other mounting positions / up to 40 °C, max.3 mA
Load impedance range / lower limit48 Ω
Load impedance range / upper limit4 kΩ
Encoder / Connectable encoders / 2-wire BEROSNo
Isolation / Isolation, digital outputs / between the channels and the backplane busYes
Isolation / Galvanic isolation, digital inputs / between the channels and the backplane busYes
Dimensions and weight / Width160 mm
Dimensions and weight / Height125 mm
Dimensions and weight / Depth130 mm
Weights / Weight, approx.750 g

Communication and configuration

  • Product status / associated programming package: STEP 7 V5.2 or higher + SP 1 + HF 1 and option package S7- Technology
  • Memory / Load memory / pluggable (MMC): Yes; min. 4 MB required
  • Memory / Load memory / pluggable (MMC), max.: 8 MByte
  • Communication functions / PG/OP communication: Yes
  • Communication functions / Routing: Yes
  • Communication functions / Global data communication / supported: Yes
  • Communication functions / Global data communication / Size of GD packets, max.: 22 Byte
  • Communication functions / S7 basic communication / supported: Yes

Scope of supply

We will confirm the specific scope of supply, packaging and any accessories in the quotation. For replacement CPUs, we will also check the memory card and other items needed for commissioning.

Frequently asked questions

Is the same product family enough to identify a replacement?

The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.

What must be checked for firmware and a STEP 7 or TIA Portal project?

Check the replacement unit's actual firmware and the availability of this exact CPU in the hardware catalog of your engineering version. TIA Portal support cannot be confirmed from the product family name alone. A change of CPU type normally requires modification or at least a thorough check of the project.

Does the memory card need to be checked?

Yes. Check the memory card type and capacity, program and data contents and the original CPU's backup arrangement. We will specify the required card and accessories in the quotation.

Can you assess a faulty part?

Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.

Why buy from FOXON

1

Replacement part availability

We will check current part availability and confirm the possible delivery date before you order.

2

New original and refurbished parts

We will specify the available version and condition of the particular unit in the quotation.

3

Parts with a warranty

We will confirm the warranty period according to the part condition and specific quotation.

4

Diagnostics and repairs

For a faulty unit, we will check the options for diagnostics and professional repair.

More than 3,500customers
We deliver tomore than 100 countries
Express delivery?We will check. Contact us now.

Part conditions available for sale

Part conditions and warranty
  • New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
  • New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
  • New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
  • New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
  • Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
  • Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
  • Used (U): Functional used part. 3-month warranty.

Sales, repairs and buyback of automation parts

We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.

More about parts sales, repairs and buyback

Need to buy or repair this part?

Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.

Request a quote for purchase or repair

Accessories4