from 1 369,72 EUR Incl. VAT
6ES7317-2FK13-0AB0
- SIEMENS
- SIMATIC S7-300
- CPU
- 6ES7317-2FK13-0AB0
6ES7317-2FK13-0AB0
SIMATIC S7-300 CPU317F-2 PN/DP, Central processing unit with 1024 KB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface Ethernet PROFINET, Micro Memory Card required Can be used with software package S7 Distributed Safety from V5.4 More
Code: 6ES7317-2FK13-0AB0
SIMATIC S7-300 CPU317F-2 PN/DP, Central processing unit with 1024 KB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface Ethernet PROFINET, Micro Memory Card required Can be used with software package S7 Distributed Safety from V5.4 More
Code: 6ES7317-2FK13-0AB0
Part Sales 2
| Condition | Code | Warranty | Availability |
Delivery Express? | Price excl. VAT | |
|---|---|---|---|---|---|---|
| Refurbished (R) | 6ES7317-2FK13-0AB0 R | 12/24 months | In external stock 3 pcs |
Within 2-4 days / Express
|
On request
|
|
| Used (U) | 6ES7317-2FK13-0AB0 U | 3 months | In external stock 2 pcs |
Within 2-4 days / Express
|
On request
|
Repair of the part
| Name | Code | Delivery | Warranty | Price excl. VAT | |
|---|---|---|---|---|---|
| Complete part repair | 6ES7317-2FK13-0AB0 O | 3-6 weeks | 24 months | On request | Enquire a repair |
6ES7317-2FK13-0AB0 – CPU 317F-2 PN/DP
Siemens SIMATIC S7-300 CPU 317F-2 PN/DP.
Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.
CPU application
The CPU executes the user program and handles SIMATIC S7-300 communication. Before replacement, check the complete order number, actual firmware version, memory card and interface configuration in the original project.
Technical specifications
| Manufacturer | Siemens |
|---|---|
| Order number | 6ES7317-2FK13-0AB0 |
| Product type designation | CPU 317F-2 PN/DP |
| Product status / associated programming package | STEP 7 V5.3 SP3 or higher + HW update, S7 Distributed Safety V5.4 or higher |
| Supply voltages / Rated value / DC 24 V | Yes |
| Supply voltages / Rated value / permissible range, lower limit (DC) | 20.4 V |
| Supply voltages / Rated value / permissible range, upper limit (DC) | 28.8 V |
| Voltages and currents / external protection for supply cables (recommendation) | min. 2 A |
| Current consumption / Inrush current, typ. | 2.5 A |
| Current consumption / I²t | 1 A²s |
| Current consumption / Current consumption (in no-load operation), typ. | 100 mA |
| Current consumption / Current consumption (rated value) | 650 mA |
| Power loss, typ. | 3.5 W |
| Memory / RAM / integrated | 1 MByte; for program and data, less the display data |
| Memory / RAM / expandable | No |
| Memory / Load memory / pluggable (MMC) | Yes |
| Memory / Load memory / pluggable (MMC), max. | 8 MByte |
| Memory / Backup / present | Yes; Guaranteed by MMC (maintenance-free) |
| Memory / Backup / without battery | Yes; Program and data |
| CPU/blocks / DB / Number, max. | 2,047; Number band: 1 to 2047 |
| CPU/blocks / DB / Size, max. | 64 KByte |
| CPU/blocks / FB / Number, max. | 2,048; Number band: 0 to 2047 |
| CPU/blocks / FB / Size, max. | 64 KByte |
| CPU/blocks / FC / Number, max. | 2,048; Number band: 0 to 2047 |
| CPU/blocks / FC / Size, max. | 64 KByte |
| CPU/blocks / OB / Number, max. | See Operation List |
| CPU/blocks / OB / Size, max. | 64 KByte |
| CPU/blocks / Nesting depth / per priority class | 16 |
| CPU/blocks / Nesting depth / additional within an error OB | 4 |
| CPU/processing times / for bit operations, min. | 0.05 µs |
| CPU/processing times / for word operations, min. | 0.2 µs |
| CPU/processing times / for fixed point arithmetic, min. | 0.2 µs |
| CPU/processing times / for floating point arithmetic, min. | 1 µs |
| Times/counters and their remanence / S7 counter / Number | 512 |
| Times/counters and their remanence / S7 counter / of which remanent without battery / adjustable | Yes |
| Times/counters and their remanence / S7 counter / of which remanent without battery / lower limit | 0 |
| Times/counters and their remanence / S7 counter / of which remanent without battery / upper limit | 511 |
| Remanence / adjustable | Yes |
| Remanence / lower limit | 0 |
| Remanence / upper limit | 511 |
| Counting range / adjustable | Yes |
| Counting range / lower limit | 0 |
| Counting range / upper limit | 999 |
| IEC counter / present | Yes |
| IEC counter / Type | SFB |
| S7 times / Number | 512 |
| S7 times / Remanence / adjustable | Yes |
| S7 times / Remanence / lower limit | 0 |
| S7 times / Remanence / upper limit | 511 |
| S7 times / Remanence / preset | no retentivity |
| S7 times / Time range / lower limit | 10 ms |
| S7 times / Time range / upper limit | 9,990 s |
| IEC timer / present | Yes |
| IEC timer / Type | SFB |
| Data areas and their remanence / Flag / Number, max. | 4,096 Byte |
| Data areas and their remanence / Flag / Remanence available | Yes; MB 0 to MB 4095 |
| Data areas and their remanence / Flag / Number of clock memories | 8; 1 memory byte |
| Data areas and their remanence / Data blocks / Number, max. | 2,047; from DB 1 to DB 2047 |
| Data areas and their remanence / Data blocks / Size, max. | 64 KByte |
| Data areas and their remanence / Data blocks / Remanence adjustable | Yes; via non-retain property on DB |
| Data areas and their remanence / Data blocks / Remanence preset | Yes |
| Data areas and their remanence / Local data / per priority class, max. | 1,024 Byte |
| Address area / I/O address area / Inputs | 8 KByte |
| Address area / I/O address area / Outputs | 8 KByte |
| Address area / I/O address area / of which, distributed / Inputs | 8 KByte |
| Address area / I/O address area / of which, distributed / Outputs | 8 KByte |
| Process image / Inputs | 2,048 Byte |
| Process image / Outputs | 2,048 Byte |
| Process image / Inputs, adjustable | 2,048 Byte |
| Process image / Outputs, adjustable | 2,048 Byte |
| Process image / Inputs, preset | 1,024 Byte |
| Process image / Outputs, preset | 1,024 Byte |
| Digital channels / Inputs | 65,536 |
| Digital channels / Outputs | 65,536 |
| Digital channels / Inputs, of which central | 1,024 |
| Digital channels / Outputs, of which central | 1,024 |
| Analog channels / Inputs | 4,096 |
| Analog channels / Outputs | 4,096 |
| Analog channels / Inputs, of which central | 256 |
| Analog channels / Outputs, of which central | 256 |
| Hardware config. / Central devices, max. | 1 |
| Hardware config. / Expansion devices, max. | 3 |
| Hardware config. / Racks, max. | 4 |
| Hardware config. / Modules per rack, max. | 8 |
| Hardware config. / Number of DP masters / integrated | 1 |
| Hardware config. / Number of DP masters / via CP | 4 |
| Hardware config. / Number of operable FMs and CPs (recommended) / FM | 8 |
| Hardware config. / Number of operable FMs and CPs (recommended) / CP, point-to-point | 8 |
| Hardware config. / Number of operable FMs and CPs (recommended) / CP, LAN | 10 |
| Time / Clock / Hardware clock (real-time clock) | Yes |
| Time / Clock / Battery backed and synchronized | Yes |
| Time / Clock / Deviation per day, max. | 10 s |
| Time / Operating hours counter / Number | 4 |
| Time / Operating hours counter / Number/Number range | 0 to 3 |
| Time / Operating hours counter / Range of values | 0 to 2^31 hours (when using SFC101) |
| Time / Operating hours counter / Granularity | 1 hour |
| Time / Operating hours counter / remanent | Yes; must be restarted at each warm restart |
| Time / Clock synchronization / supports | Yes |
| Time / Clock synchronization / to MPI, Master | Yes |
| Time / Clock synchronization / to MPI, Slave | Yes |
| Time / Clock synchronization / in AS, Master | Yes |
| Time / Clock synchronization / in AS, Slave | Yes |
| S7 message functions / Number of login stations for message functions, max. | 32; depending on the configured connections for PG-/ OP- and S7- basic commmunication |
| S7 message functions / Process diagnostic messages | Yes |
| S7 message functions / simultaneously active Alarm-S blocks, max. | 60 |
| Test commissioning functions / Status/control / Status/control variable | Yes |
| Test commissioning functions / Status/control / Variables | Inputs, outputs, memory bits, DB, times, counters |
| Monitoring functions / Number of variables, max. | 30 |
| Monitoring functions / of which status variable, max. | 30 |
| Monitoring functions / of which control variable, max. | 14 |
| Monitoring functions / Forcing | Yes |
| Monitoring functions / Forcing / Force, variables | Inputs, outputs |
| Monitoring functions / Forcing / Forcing, number of variables, max. | 10 |
| Monitoring functions / Status block | Yes |
| Monitoring functions / Single step | Yes |
| Monitoring functions / Number of breakpoints | 2 |
| Monitoring functions / Diagnostic buffer / present | Yes |
| Monitoring functions / Diagnostic buffer / Number of entries, max. | 100 |
| Monitoring functions / Diagnostic buffer / adjustable | No |
| Communication functions / PG/OP communication | Yes |
| Communication functions / Routing | Yes |
| Communication functions / Global data communication / supported | Yes |
| Communication functions / Global data communication / Size of GD packets, max. | 22 Byte |
| Communication functions / S7 basic communication / supported | Yes |
| Communication functions / S7 communication / supported | Yes |
| Communication functions / S5-compatible communication / supported | Yes; via CP and loadable FC |
| Communication functions / Open IE communication / TCP/IP | Yes; via integrated PROFINET interface and loadable FBs |
| Communication functions / Open IE communication / Number of connections, max. | 8 |
| Communication functions / Open IE communication / Data length, max. | 1,460 Byte |
| Number of connections / overall | 32 |
| Number of connections / usable for PG communication | 31 |
| Number of connections / usable for OP communication | 31 |
| Number of connections / usable for S7 basic communication | 30 |
| PROFINET CBA (at set setpoint communication load) / Setpoint for the CPU communication load | 50% |
| PROFINET CBA (at set setpoint communication load) / Number of remote interconnection partners | 32 |
| PROFINET CBA (at set setpoint communication load) / Number of functions, master/slave | 17 |
| PROFINET CBA (at set setpoint communication load) / Total of all master/slave connections | 1,000 |
| PROFINET CBA (at set setpoint communication load) / Data length of all incoming connections master/slave, max. | 4,000 Byte |
| PROFINET CBA (at set setpoint communication load) / Data length of all outgoing connections master/slave, max. | 4,000 Byte |
| PROFINET CBA (at set setpoint communication load) / Number of device-internal and PROFIBUS interconnec- tions | 500 |
| PROFINET CBA (at set setpoint communication load) / Data length of device- internal und PROFIBUS interconnections, max. | 4,000 Byte |
| PROFINET CBA (at set setpoint communication load) / Data length per connection, max. | 1,400 Byte |
| PROFINET CBA (at set setpoint communication load) / Remote interconnections with acyclic transmission / Sampling frequency: sampling interval, min. | 500 ms |
| PROFINET CBA (at set setpoint communication load) / Remote interconnections with acyclic transmission / Number of incoming inter- connections | 100 |
| PROFINET CBA (at set setpoint communication load) / Remote interconnections with acyclic transmission / Number of outgoing inter- connections | 100 |
| PROFINET CBA (at set setpoint communication load) / Remote interconnections with acyclic transmission / Data length of all incoming interconnections, max. | 2,000 Byte |
| PROFINET CBA (at set setpoint communication load) / Remote interconnections with acyclic transmission / Data length of all outgoing interconnections, max. | 2,000 Byte |
| PROFINET CBA (at set setpoint communication load) / Remote interconnections with acyclic transmission / Data length per connection, max. | 1,400 Byte |
| PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Transmission frequency: transmission interval, min. | 10 ms |
| PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Number of incoming interconnections | 200 |
| PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Number of outgoing interconnections | 200 |
| PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission (cont.) / Data length of all incoming interconnections, max. | 2,000 Byte |
| PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission (cont.) / Data length of all outgoing interconnections, max. | 2,000 Byte |
| PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission (cont.) / Data length per connection, max. | 450 Byte |
| PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Number of log-in stations for HMI variables (PN OPC/iMap) | 3; 2 * PN OPC / 1 * iMap |
| PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / HMI variable updating | 500 ms |
| PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Number of HMI variables | 200 |
| PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Data length of all HMI variables, max. | 2,000 Byte |
| PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / supported | Yes |
| PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / Number of linked PROFIBUS devices | 16 |
| PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / Data length per connection, max. | 240 Byte; Slave-dependent |
| PROFINET CBA (at 50 % communication load) / Data length for arrays and structures (local interconnection), max. | Slave-dependent |
| PROFINET CBA (at 50 % communication load) / HMI variables via PROFINET (acyclic) / Number of log-in stations for HMI variables (PN OPC/iMap) | 2 * PN OPC / 1 * iMap |
| 1st interface / Type of interface | Integral RS 485 interface |
| 1st interface / Physics | RS 485 |
| 1st interface / isolated | Yes |
| 1st interface / Power supply to interface (15 to 30 V DC), max. | 200 mA |
| 1st interface / Functionality / MPI | Yes |
| 1st interface / Functionality / DP master | Yes |
| 1st interface / Functionality / DP slave | Yes |
| 1st interface / Functionality / Point-to-point coupling | No |
| 1st interface / MPI / Number of connections | 16 |
| 1st interface / MPI / Services / PG/OP communication | Yes |
| 1st interface / MPI / Services / Routing | Yes |
| 1st interface / MPI / Services / Global data communication | Yes |
| 1st interface / MPI / Services / S7 basic communication | Yes |
| 1st interface / MPI / Services / S7 communication | Yes |
| 1st interface / MPI / Services / S7 communication, as client | No |
| 1st interface / MPI / Services / S7 communication, as server | Yes |
| MPI (continued) / Transmission speeds, max. | 12 Mbit/s |
| DP master / Services / PG/OP communication | Yes |
| DP master / Services / Routing | Yes |
| DP master / Services / Global data communication | No |
| DP master / Services / S7 basic communication | Yes |
| DP master / Services / S7 communication | Yes |
| DP master / Services / S7 communication, as client | No |
| DP master / Services / S7 communication, as server | Yes |
| DP master / Services / Equidistance support | Yes |
| DP master / Services / SYNC/FREEZE | Yes |
| DP master / Services / DPV1 | Yes |
| DP master / Transmission speeds, max. | 12 Mbit/s |
| DP master / Number of DP slaves, max. | 124 |
| DP slave / Services / Routing | Yes; only when interface active |
| DP slave / Services / Global data communication | No |
| DP slave / Services / S7 basic communication | Yes |
| DP slave / Services / S7 communication | Yes |
| DP slave / Services / S7 communication, as client | No |
| DP slave / Services / S7 communication, as server | Yes |
| DP slave / Services / direct data exchange (cross traffic) | Yes |
| DP slave / Services / DPV1 | No |
| DP slave / Transmission speeds, max. | 12 Mbit/s |
| DP slave / Transfer memory / Inputs | 244 Byte |
| DP slave / Transfer memory / Outputs | 244 Byte |
| DP slave / Address area, max. | 32 |
| DP slave / Useful data per address area, max. | 32 Byte |
| 2nd interface / Type of interface | PROFINET |
| 2nd interface / Physics | Ethernet |
| 2nd interface / isolated | Yes |
| 2nd interface / Power supply to interface (15 to 30 V DC), max. | 0 mA |
| 2nd interface / automatic detection of transmission speed | Yes; (10/100 Mbit/s) |
| 2nd interface / Functionality / MPI | No |
| 2nd interface / Functionality / DP master | No |
| Functionality (continued) / DP slave | No |
| Functionality (continued) / Point-to-point coupling | No |
| Functionality (continued) / PROFINET CBA | Yes |
| Functionality (continued) / PROFINET IO controller | Yes; Firmware Status V2.3 or higher |
| PROFINET CBA / Acyclic transmission | Yes |
| PROFINET CBA / Cyclic transmission | Yes |
| PROFINET IO controller / Services / PG/OP communication | Yes |
| PROFINET IO controller / Services / Routing | Yes |
| PROFINET IO controller / Services / S7 communication | Yes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32 |
| PROFINET IO controller / Services / open IE communication | Yes; via TCP/IP |
| PROFINET IO controller / Transmission speed, max. | 100 Mbit/s |
| PROFINET IO controller / Number of connectable IO-devices, max. | 128 |
| PROFINET IO controller / Update time | 1 to 512 ms (minimum value depends on communication share set for PROFINET IO, on the number of IO devices and on the number of configured useful data items) |
| PROFINET IO controller / Address area / Inputs, max. | 8 KByte |
| PROFINET IO controller / Address area / Outputs, max. | 8 KByte |
| PROFINET IO controller / Useful data consistency, max. | 256 Byte |
| CPU/programming / Programming language / STEP 7 | Yes; V 5.3 SP3 or higher + HW update |
| CPU/programming / Programming language / LAD | Yes |
| CPU/programming / Programming language / FUP | Yes |
| CPU/programming / Programming language / AWL | Yes |
| CPU/programming / Programming language / SCL | Yes |
| CPU/programming / Programming language / CFC | Yes |
| CPU/programming / Programming language / GRAPH | Yes |
| CPU/programming / Programming language / HiGraph | Yes |
| CPU/programming / Operational stocks | See Operation List |
| CPU/programming / Nesting levels | 8 |
| CPU/programming / User program protection/password protection | Yes |
| CPU/programming / System functions (SFC) | See Operation List |
| CPU/programming / System function blocks (SFB) | See Operation List |
| Dimensions and weight / Width | 80 mm |
| Dimensions and weight / Height | 125 mm |
| Dimensions and weight / Depth | 130 mm |
| Weights / Weight, approx. | 460 g |
Communication and configuration
- Product status / associated programming package: STEP 7 V5.3 SP3 or higher + HW update, S7 Distributed Safety V5.4 or higher
- Memory / Load memory / pluggable (MMC): Yes
- Memory / Load memory / pluggable (MMC), max.: 8 MByte
- Communication functions / PG/OP communication: Yes
- Communication functions / Routing: Yes
- Communication functions / Global data communication / supported: Yes
- Communication functions / Global data communication / Size of GD packets, max.: 22 Byte
- Communication functions / S7 basic communication / supported: Yes
Scope of supply
We will confirm the specific scope of supply, packaging and any accessories in the quotation. For replacement CPUs, we will also check the memory card and other items needed for commissioning.
Frequently asked questions
Is the same product family enough to identify a replacement?
The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.
What must be checked for firmware and a STEP 7 or TIA Portal project?
Check the replacement unit's actual firmware and the availability of this exact CPU in the hardware catalog of your engineering version. TIA Portal support cannot be confirmed from the product family name alone. A change of CPU type normally requires modification or at least a thorough check of the project.
Does the memory card need to be checked?
Yes. Check the memory card type and capacity, program and data contents and the original CPU's backup arrangement. We will specify the required card and accessories in the quotation.
Can you assess a faulty part?
Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.
Why buy from FOXON
Replacement part availability
We will check current part availability and confirm the possible delivery date before you order.
New original and refurbished parts
We will specify the available version and condition of the particular unit in the quotation.
Parts with a warranty
We will confirm the warranty period according to the part condition and specific quotation.
Diagnostics and repairs
For a faulty unit, we will check the options for diagnostics and professional repair.
Part conditions available for sale
Part conditions and warranty
- New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
- New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
- New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
- New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
- Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
- Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
- Used (U): Functional used part. 3-month warranty.


Sales, repairs and buyback of automation parts
We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.
Need to buy or repair this part?
Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.
Request a quote for purchase or repairHighlighted items are mandatory.










