6ES7315-2FH13-0AB0

6ES7315-2FH13-0AB0

Sales, Repair, Purchase

SIEMENS

SIMATIC S7-300 CPU315F-2 PN/DP, Central processing unit with 256 KB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface Ethernet PROFINET, Micro Memory Card required Can be used with software package S7 Distributed Safety from V5.4 More

Code: 6ES7315-2FH13-0AB0

from 632 EUR excl. VAT (764,72 EUR Incl. VAT)
Total in stock: 21 pcs External stock 21 pcs
Variant does not exist

Rezervace termínu

Get a quote
SIEMENS

SIMATIC S7-300 CPU315F-2 PN/DP, Central processing unit with 256 KB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface Ethernet PROFINET, Micro Memory Card required Can be used with software package S7 Distributed Safety from V5.4 More

Code: 6ES7315-2FH13-0AB0

Part Sales 2

Condition Code Warranty Availability Delivery
Express?
Price excl. VAT
New in sealed box (NC) 6ES7315-2FH13-0AB0 NC 12/24 months In external stock 2 pcs
Within 2-4 days / Express
On request
Refurbished (R) 6ES7315-2FH13-0AB0 R 12/24 months In external stock 19 pcs
Within 2-4 days / Express
On request

Repair of the part

Name Code Delivery Warranty Price excl. VAT
Complete part repair 6ES7315-2FH13-0AB0 O 3-6 weeks 24 months On request Enquire a repair

6ES7315-2FH13-0AB0 – CPU 315F-2 PN/DP

Siemens SIMATIC S7-300 CPU 315F-2 PN/DP.

Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.

Request a quote for purchase or repair
256 KByte; for program and data, less the display dataMemory / RAM / integrated
RS 4851st interface / Physics
Ethernet2nd interface / Physics

CPU application

The CPU executes the user program and handles SIMATIC S7-300 communication. Before replacement, check the complete order number, actual firmware version, memory card and interface configuration in the original project.

Technical specifications

ManufacturerSiemens
Order number6ES7315-2FH13-0AB0
Product type designationCPU 315F-2 PN/DP
Product status / associated programming packageSTEP 7 V5.3 SP3 or higher + HW update, S7 Distributed Safety V5.4 or higher
Supply voltages / Rated value / DC 24 VYes
Supply voltages / Rated value / permissible range, lower limit (DC)20.4 V
Supply voltages / Rated value / permissible range, upper limit (DC)28.8 V
Voltages and currents / external protection for supply cables (recommendation)min. 2 A
Current consumption / Inrush current, typ.2.5 A
Current consumption / I²t1 A²s
Current consumption / Current consumption (in no-load operation), typ.100 mA
Current consumption / Current consumption (rated value)650 mA
Power loss, typ.3.5 W
Memory / RAM / integrated256 KByte; for program and data, less the display data
Memory / RAM / expandableNo
Memory / Load memory / pluggable (MMC)Yes
Memory / Load memory / pluggable (MMC), max.8 MByte
Memory / Load memory / expandable FEPROMPluggable via MMC
Memory / Backup / presentYes; Guaranteed by MMC (maintenance-free)
Memory / Backup / without batteryYes; Program and data
CPU/blocks / DB / Number, max.1,023; Number band: 1 to 1023
CPU/blocks / DB / Size, max.16 KByte
CPU/blocks / FB / Number, max.1,024; Number band: 0 to 2047
CPU/blocks / FB / Size, max.16 KByte
CPU/blocks / FC / Number, max.1,024; Number band: 0 to 2047
CPU/blocks / FC / Size, max.16 KByte
CPU/blocks / OB / Number, max.See Operation List
CPU/blocks / OB / Size, max.16 KByte
CPU/blocks / Nesting depth / per priority class8
CPU/blocks / Nesting depth / additional within an error OB4
CPU/processing times / for bit operations, min.0.1 µs
CPU/processing times / for word operations, min.0.2 µs
CPU/processing times / for fixed point arithmetic, min.2 µs
CPU/processing times / for floating point arithmetic, min.3 µs
Times/counters and their remanence / S7 counter / Number256
Times/counters and their remanence / S7 counter / of which remanent without battery / adjustableYes
Times/counters and their remanence / S7 counter / of which remanent without battery / lower limit0
Times/counters and their remanence / S7 counter / of which remanent without battery / upper limit255
Remanence / adjustableYes
Remanence / lower limit0
Remanence / upper limit255
Counting range / adjustableYes
Counting range / lower limit0
Counting range / upper limit999
IEC counter / presentYes
IEC counter / TypeSFB
S7 times / Number256
S7 times / Remanence / adjustableYes
S7 times / Remanence / lower limit0
S7 times / Remanence / upper limit255
S7 times / Remanence / presetno retentivity
S7 times / Time range / lower limit10 ms
S7 times / Time range / upper limit9,990 s
IEC timer / presentYes
IEC timer / TypeSFB
Data areas and their remanence / Flag / Number, max.2,048 Byte
Data areas and their remanence / Flag / Remanence availableYes; MB 0 to MB 2047
Data areas and their remanence / Flag / Number of clock memories8; 1 memory byte
Data areas and their remanence / Data blocks / Number, max.1,023; from DB 1 to DB 1023
Data areas and their remanence / Data blocks / Size, max.16 KByte
Data areas and their remanence / Data blocks / Remanence adjustableYes; via non-retain property on DB
Data areas and their remanence / Data blocks / Remanence presetYes
Data areas and their remanence / Local data / per priority class, max.1,024 Byte; per block max. 510
Address area / I/O address area / Inputs2 KByte
Address area / I/O address area / Outputs2 KByte
Address area / I/O address area / of which, distributed / Inputs2 KByte
Address area / I/O address area / of which, distributed / Outputs2 KByte
Process image / Inputs384 Byte
Process image / Outputs384 Byte
Digital channels / Inputs16,384
Digital channels / Outputs16,384
Digital channels / Inputs, of which central1,024; max.
Digital channels / Outputs, of which central1,024; max.
Analog channels / Inputs1,024
Analog channels / Outputs1,024
Analog channels / Inputs, of which central256; max.
Analog channels / Outputs, of which central256; max.
Hardware config. / Central devices, max.1
Hardware config. / Expansion devices, max.3
Hardware config. / Racks, max.4
Hardware config. / Modules per rack, max.8
Hardware config. / Number of DP masters / integrated1
Hardware config. / Number of DP masters / via CP4
Hardware config. / Number of operable FMs and CPs (recommended) / FM8
Hardware config. / Number of operable FMs and CPs (recommended) / CP, point-to-point8
Hardware config. / Number of operable FMs and CPs (recommended) / CP, LAN10
Time / Clock / Hardware clock (real-time clock)Yes
Time / Clock / Battery backed and synchronizedYes
Time / Clock / Deviation per day, max.10 s
Time / Operating hours counter / Number1
Time / Operating hours counter / Number/Number range0
Time / Operating hours counter / Granularity1 hour
Time / Operating hours counter / remanentYes; must be restarted at each warm restart
Time / Clock synchronization / supportsYes
Time / Clock synchronization / to MPI, MasterYes
Time / Clock synchronization / to MPI, SlaveYes
Time / Clock synchronization / in AS, MasterYes
Time / Clock synchronization / in AS, SlaveYes
S7 message functions / Number of login stations for message functions, max.16; (depending on the configured connections for PG-/OP and S7 basic communication)
S7 message functions / Process diagnostic messagesYes
S7 message functions / simultaneously active Alarm-S blocks, max.40
Test commissioning functions / Status/control / Status/control variableYes
Test commissioning functions / Status/control / VariablesInputs, outputs, memory bits, DB, times, counters
Monitoring functions / Number of variables, max.30
Monitoring functions / of which status variable, max.30
Monitoring functions / of which control variable, max.14
Monitoring functions / ForcingYes
Monitoring functions / Forcing / Force, variablesInputs, outputs
Monitoring functions / Forcing / Forcing, number of variables, max.10
Monitoring functions / Status blockYes
Monitoring functions / Single stepYes
Monitoring functions / Number of breakpoints2
Monitoring functions / Diagnostic buffer / presentYes
Monitoring functions / Diagnostic buffer / Number of entries, max.100
Monitoring functions / Diagnostic buffer / adjustableNo
Communication functions / PG/OP communicationYes
Communication functions / RoutingYes
Communication functions / Global data communication / supportedYes
Communication functions / Global data communication / Size of GD packets, max.22 Byte
Communication functions / S7 basic communication / supportedYes
Communication functions / S7 communication / supportedYes
Communication functions / S5-compatible communication / supportedYes; via CP and loadable FC
Communication functions / Open IE communication / TCP/IPYes; via integrated PROFINET interface and loadable FBs
Communication functions / Open IE communication / Number of connections, max.8
Communication functions / Open IE communication / Data length, max.1,460 Byte
Number of connections / overall16
Number of connections / usable for PG communication15; max.
Number of connections / usable for OP communication15
Number of connections / usable for S7 basic communication14
Number of connections / usable for routingX1 as MPI: max. 10; X1 as DP-master: max. 24; X1 as DP-slave (active): max. 14; X2 as PROFINET: max. 24
PROFINET CBA (at set setpoint communication load) / Setpoint for the CPU communication load50%
PROFINET CBA (at set setpoint communication load) / Number of remote interconnection partners32
PROFINET CBA (at set setpoint communication load) / Number of functions, master/slave17
PROFINET CBA (at set setpoint communication load) / Total of all master/slave connections1.000
PROFINET CBA (at set setpoint communication load) / Data length of all incoming connections master/slave, max.4,000 Byte
PROFINET CBA (at set setpoint communication load) / Data length of all outgoing connections master/slave, max.4,000 Byte
PROFINET CBA (at set setpoint communication load) / Number of device-internal and PROFIBUS interconnec- tions500
PROFINET CBA (at set setpoint communication load) / Data length of device- internal und PROFIBUS interconnections, max.4,000 Byte
PROFINET CBA (at set setpoint communication load) / Data length per connection, max.1,400 Byte
PROFINET CBA (at set setpoint communication load) / Remote interconnections with acyclic transmission / Sampling frequency: sampling interval, min.500 ms
PROFINET CBA (at set setpoint communication load) / Remote interconnections with acyclic transmission / Number of incoming inter- connections100
PROFINET CBA (at set setpoint communication load) / Remote interconnections with acyclic transmission / Number of outgoing inter- connections100
PROFINET CBA (at set setpoint communication load) / Remote interconnections with acyclic transmission / Data length of all incoming interconnections, max.2,000 Byte
PROFINET CBA (at set setpoint communication load) / Remote interconnections with acyclic transmission / Data length of all outgoing interconnections, max.2,000 Byte
PROFINET CBA (at set setpoint communication load) / Remote interconnections with acyclic transmission / Data length per connection, max.1,400 Byte
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Transmission frequency: transmission interval, min.10 ms
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Number of incoming interconnections200
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission / Number of outgoing interconnections200
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission (cont.) / Data length of all incoming interconnections, max.2,000 Byte
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission (cont.) / Data length of all outgoing interconnections, max.2,000 Byte
PROFINET CBA (at set setpoint communication load) / Remote interconnections with cyclic transmission (cont.) / Data length per connection, max.450 Byte
PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Number of log-in stations for HMI variables (PN OPC/iMap)3; 2 * PN OPC / 1 * iMap
PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / HMI variable updating500 ms
PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Number of HMI variables200
PROFINET CBA (at set setpoint communication load) / HMI variables via PROFINET (acyclic) / Data length of all HMI variables, max.2,000 Byte
PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / supportedYes
PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / Number of linked PROFIBUS devices16
PROFINET CBA (at set setpoint communication load) / PROFIBUS proxy functionality / Data length per connection, max.240 Byte; Slave-dependent
PROFINET CBA (at 50 % communication load) / Data length for arrays and structures (local interconnection), max.Slave-dependent
PROFINET CBA (at 50 % communication load) / HMI variables via PROFINET (acyclic) / Number of log-in stations for HMI variables (PN OPC/iMap)2 * PN OPC / 1 * iMap
1st interface / Type of interfaceIntegral RS 485 interface
1st interface / PhysicsRS 485
1st interface / isolatedYes
1st interface / Power supply to interface (15 to 30 V DC), max.200 mA
1st interface / Functionality / MPIYes
1st interface / Functionality / DP masterYes
1st interface / Functionality / DP slaveYes
1st interface / Functionality / Point-to-point couplingNo
1st interface / MPI / Number of connections16
1st interface / MPI / Services / PG/OP communicationYes
1st interface / MPI / Services / RoutingYes
1st interface / MPI / Services / Global data communicationYes
1st interface / MPI / Services / S7 basic communicationYes
1st interface / MPI / Services / S7 communicationYes
1st interface / MPI / Services / S7 communication, as clientNo
1st interface / MPI / Services / S7 communication, as serverYes
MPI (continued) / Transmission speeds, max.12 Mbit/s
DP master / Services / PG/OP communicationYes
DP master / Services / RoutingYes
DP master / Services / Global data communicationNo
DP master / Services / S7 basic communicationYes
DP master / Services / S7 communicationYes
DP master / Services / S7 communication, as clientNo
DP master / Services / S7 communication, as serverYes
DP master / Services / Equidistance supportYes
DP master / Services / SYNC/FREEZEYes
DP master / Services / DPV1Yes
DP master / Transmission speeds, max.12 Mbit/s
DP master / Number of DP slaves, max.124
DP slave / Services / RoutingYes; only when interface active
DP slave / Services / Global data communicationNo
DP slave / Services / S7 basic communicationYes
DP slave / Services / S7 communicationYes
DP slave / Services / S7 communication, as clientNo
DP slave / Services / S7 communication, as serverYes
DP slave / Services / direct data exchange (cross traffic)Yes
DP slave / Services / DPV1No
DP slave / Transmission speeds, max.12 Mbit/s
DP slave / Transfer memory / Inputs244 Byte
DP slave / Transfer memory / Outputs244 Byte
DP slave / Address area, max.32; with max. 32 bytes each
2nd interface / Type of interfacePROFINET
2nd interface / PhysicsEthernet
2nd interface / isolatedYes
2nd interface / Power supply to interface (15 to 30 V DC), max.0 mA
2nd interface / automatic detection of transmission speedYes; (10/100 Mbit/s)
2nd interface / Functionality / MPINo
2nd interface / Functionality / DP masterNo
Functionality (continued) / DP slaveNo
Functionality (continued) / Point-to-point couplingNo
Functionality (continued) / PROFINET CBAYes
Functionality (continued) / PROFINET IO controllerYes
PROFINET CBA / Acyclic transmissionYes
PROFINET CBA / Cyclic transmissionYes
PROFINET IO controller / Services / PG/OP communicationYes
PROFINET IO controller / Services / RoutingYes
PROFINET IO controller / Services / S7 communicationYes; with loadable FBs, max. configurable connections: 14, max. number of instances: 32
PROFINET IO controller / Services / open IE communicationYes; via TCP/IP
PROFINET IO controller / Transmission speed, max.100 Mbit/s
PROFINET IO controller / Number of connectable IO-devices, max.128
PROFINET IO controller / Update time1 to 512 ms (minimum value depends on communication share set for PROFINET IO, on the number of IO devices and on the number of configured useful data items)
PROFINET IO controller / Address area / Inputs, max.2 KByte
PROFINET IO controller / Address area / Outputs, max.2 KByte
PROFINET IO controller / Useful data consistency, max.256 Byte
CPU/programming / Programming language / STEP 7Yes; V 5.3 SP3 or higher + hardware update
CPU/programming / Programming language / LADYes
CPU/programming / Programming language / FUPYes
CPU/programming / Programming language / AWLYes
CPU/programming / Programming language / SCLYes
CPU/programming / Programming language / CFCYes
CPU/programming / Programming language / GRAPHYes
CPU/programming / Programming language / HiGraphYes
CPU/programming / Operational stocksSee Operation List
CPU/programming / Nesting levels8
CPU/programming / User program protection/password protectionYes
CPU/programming / System functions (SFC)See Operation List
CPU/programming / System function blocks (SFB)See Operation List
Dimensions and weight / Width80 mm
Dimensions and weight / Height125 mm
Dimensions and weight / Depth130 mm
Weights / Weight, approx.460 g

Communication and configuration

  • Product status / associated programming package: STEP 7 V5.3 SP3 or higher + HW update, S7 Distributed Safety V5.4 or higher
  • Memory / Load memory / pluggable (MMC): Yes
  • Memory / Load memory / pluggable (MMC), max.: 8 MByte
  • Memory / Load memory / expandable FEPROM: Pluggable via MMC
  • Communication functions / PG/OP communication: Yes
  • Communication functions / Routing: Yes
  • Communication functions / Global data communication / supported: Yes
  • Communication functions / Global data communication / Size of GD packets, max.: 22 Byte

Scope of supply

We will confirm the specific scope of supply, packaging and any accessories in the quotation. For replacement CPUs, we will also check the memory card and other items needed for commissioning.

Frequently asked questions

Is the same product family enough to identify a replacement?

The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.

What must be checked for firmware and a STEP 7 or TIA Portal project?

Check the replacement unit's actual firmware and the availability of this exact CPU in the hardware catalog of your engineering version. TIA Portal support cannot be confirmed from the product family name alone. A change of CPU type normally requires modification or at least a thorough check of the project.

Does the memory card need to be checked?

Yes. Check the memory card type and capacity, program and data contents and the original CPU's backup arrangement. We will specify the required card and accessories in the quotation.

Can you assess a faulty part?

Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.

Why buy from FOXON

1

Replacement part availability

We will check current part availability and confirm the possible delivery date before you order.

2

New original and refurbished parts

We will specify the available version and condition of the particular unit in the quotation.

3

Parts with a warranty

We will confirm the warranty period according to the part condition and specific quotation.

4

Diagnostics and repairs

For a faulty unit, we will check the options for diagnostics and professional repair.

More than 3,500customers
We deliver tomore than 100 countries
Express delivery?We will check. Contact us now.

Part conditions available for sale

Part conditions and warranty
  • New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
  • New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
  • New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
  • New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
  • Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
  • Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
  • Used (U): Functional used part. 3-month warranty.

Sales, repairs and buyback of automation parts

We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.

More about parts sales, repairs and buyback

Need to buy or repair this part?

Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.

Request a quote for purchase or repair

Accessories4