6AG2134-6GF00-4AA1
- SIEMENS
- SIMATIC ET 200 / DP
- SIMATIC ET 200SP
- 6AG2134-6GF00-4AA1
6AG2134-6GF00-4AA1
SIPLUS ET 200SP AI 8xI 2-/4-wire BA TX rail based on 6ES7134-6GF00-0AA1 with conformal coating, -40…+70 °C, OT4 with ST1/2 (+85 °C for 10 minutes), analog input module, suitable for BU type A0, A1, color code CC01, module diagnostics, 16 bit More
Code: 6AG2134-6GF00-4AA1
SIPLUS ET 200SP AI 8xI 2-/4-wire BA TX rail based on 6ES7134-6GF00-0AA1 with conformal coating, -40…+70 °C, OT4 with ST1/2 (+85 °C for 10 minutes), analog input module, suitable for BU type A0, A1, color code CC01, module diagnostics, 16 bit More
Code: 6AG2134-6GF00-4AA1
Repair of the part
| Name | Code | Delivery | Warranty | Price excl. VAT | |
|---|---|---|---|---|---|
| Complete part repair | 6AG2134-6GF00-4AA1 O | 3-6 weeks | 24 months | On request | Enquire a repair |
6AG2134-6GF00-4AA1 – AI 8xI 2-/4-wire BA
Siemens 6AG2134-6GF00-4AA1: SIPLUS ET 200SP AI 8xI 2-/4-wire BA TX rail based on 6ES7134-6GF00-0AA1 with conformal coating, -40…+70 °C, OT4 with ST1/2 (+85 °C for 10 minutes), analog input module, suitable for BU type A0, A1, color code CC01, module diagnostics, 16 bit.
Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.
Technical specifications
| Manufacturer | Siemens |
|---|---|
| Order number | 6AG2134-6GF00-4AA1 |
| Product type | AI 8xI 2-/4-wire BA |
| Firmware version / FW update possible | Yes |
| Supply voltage / Rated value (DC) | 24 V |
| Input current / Current consumption (rated value) | 25 mA; rated voltage, all channels active, no load |
| Input current / Current consumption, max. | 725 mA; worst case voltage, all channels active, max. load, no derating |
| Encoder supply / 24 V encoder supply / Output current, max. | 0.7 A; total current of all encoders/channels |
| Power loss / Power loss, typ. | 0.7 W; rated voltage, 50 % active channels, 50 % of range |
| Analog inputs / Number of analog inputs | 8; Single-ended |
| Analog inputs / permissible input current for current input (destruction limit), | 50 mA |
| Analog inputs / Input ranges (rated values), currents / 0 to 20 mA | Yes |
| Analog inputs / Input ranges (rated values), currents / Input resistance (0 to 20 mA) | 100 Ω; 15 bit |
| Analog inputs / Input ranges (rated values), currents / -20 mA to +20 mA | Yes |
| Analog inputs / Input ranges (rated values), currents / Input resistance (-20 mA to +20 mA) | 100 Ω; 16 bit incl. sign |
| Analog inputs / Input ranges (rated values), currents / 4 mA to 20 mA | Yes |
| Analog inputs / Input ranges (rated values), currents / Input resistance (4 mA to 20 mA) | 100 Ω; 15 bit |
| Analog inputs / Cable length / shielded, max. | 200 m |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max. | 16 bit |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Integration time, parameterizable | Yes |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Interference voltage suppression for interference | 16.67 / 50 / 60 / 4 800 (16.67 / 50 / 60) |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Conversion time (per channel) | 180 / 60 / 50 / 0.625 (67.5 / 22.5 / 18.75) ms |
| Ambient temperature during operation / horizontal installation, min. | -40 °C; = Tmin (incl. condensation/frost) |
| Ambient temperature during operation / horizontal installation, max. | 70 °C; = Tmax; +85 °C for 10 min (OT4, ST1/ST2 acc. to EN 50155) |
| Ambient temperature during operation / vertical installation, min. | -40 °C; = Tmin |
| Ambient temperature during operation / vertical installation, max. | 50 °C; = Tmax |
| Width | 15 mm |
| Height | 73 mm |
| Depth | 58 mm |
| Weights / Weight, approx. | 31 g |
Part variants and further information
- New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
- New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
- New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
- New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
- Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
- Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
- Used (U): Functional used part. 3-month warranty.


Buy parts and arrange repairs with FOXON
We supply new original and refurbished parts with a warranty. We confirm current availability and the possible delivery date before you place an order. For faulty parts, we check the options for diagnostics and professional repair.
Need to buy or repair this part?
Send the full order number, required quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.
Request a quote for purchase or repairHighlighted items are mandatory.