LAPP 2170222 - PROFIBUS DP trailing cable
LAPP 2170222 - PROFIBUS DP trailing cable, 1 pair 0.25 mm² / AWG 24, PUR, halogen-free, double-shielded, diameter 8 mm. Not FastConnect. Sold by the metre, minimum order 10 m. More
Code: 2170222
LAPP 2170222 - PROFIBUS DP trailing cable, 1 pair 0.25 mm² / AWG 24, PUR, halogen-free, double-shielded, diameter 8 mm. Not FastConnect. Sold by the metre, minimum order 10 m. More
Code: 2170222
PROFIBUS DP trailing cable
PUR · halogen-free · flexible applications
LAPP 2170222 UNITRONIC® BUS PB FD P is a shielded data cable designed for mobile PROFIBUS DP applications, energy chains and frequently moving machine parts. It features 1 pair of 0.25 mm² (AWG 24) copper conductors, double screening and a halogen-free, oil- and abrasion-resistant PUR sheath.
Send the required length and installation method. We will check the suitable cable version and connectors.
Use during the installation and maintenance of the network
The cable is suitable for use in power chains and on repeatedly moving machine parts. The design must take into account the bending radius, temperature, speed, acceleration and travel distance. Torsional use is limited to operating conditions typical of cable loops in wind turbines; it does not constitute general approval for any robotic movement.
Sold by the metre, in lengths of 10 metres or more
We sell the cable by the metre and cut it to length. The minimum order is 10 metres. Enter the required length in metres in the ‘Quantity’ field, for example 25 for a length of 25 metres. We will confirm the availability and delivery method for the specific length before you place your order.
We supply the cable without connectors fitted. We will confirm the length, packaging and availability of the specific quantity in our quotation.
Cable construction and double shielding
One pair of red and green conductors is protected by aluminium foil and a tinned copper braid. The PUR sheath is halogen-free, resistant to mineral oils and abrasion. The cable is flame-retardant in accordance with IEC 60332-1-2. This is not a power cable.

Bend radius and operating conditions
For applications involving movement, allow for a minimum bending radius of 65 mm and a temperature range of -30 to +70 °C. Route the cable through the chain without twisting it, ensuring adequate strain relief and allowing room for movement. The number of bending cycles depends on the specific operating conditions; the minimum bend radius alone is no guarantee of service life. For a design at this bending-radius limit, obtain manufacturer confirmation for the specific application.
You will also find the design data for moving applications amongst the downloadable files. The indicative service life given in the selection table applies only to the specified operating conditions.
Cable end preparation and connector assembly
LAPP 2170222 is not a FastConnect version. To prepare the sheath and screening, select a tool and procedure suitable for its construction. The Siemens stripping tool for PROFIBUS FastConnect cannot be automatically recommended solely on the basis of the cable having the same diameter.
When connecting, ensure that the stripped lengths and connection method comply with the specifications for the selected connector. In a standard PROFIBUS DP connection, A is the green wire and B is the red wire. The shield must make proper contact with the connector or the designated shielding element. After installation, check the wiring and network communication.
Cable length and segment termination
Design the segment length according to the network speed, the attenuation of the specific cable and the overall topology. Trailing cables have different electrical parameters to fixed standard cables. Therefore, do not automatically apply the maximum length table for a different type of cable. After modifying the network, we recommend verifying the signal and communication using the ProfiTrace2 tester.
A segment is a section of the network in which the electrical signal is the same. Every PROFIBUS DP metallic segment must be properly terminated at both ends with a terminating resistor that is switched on and powered. It is the physical ends of the cable run that are decisive, not the lowest and highest device addresses.
Technical specifications 2170222
| Manufacturer | LAPP |
|---|---|
| Order number | 2170222 |
| Model designation | UNITRONIC® BUS PB FD P 1X2X0,64 |
| Uses | Moving applications, energy chains |
| Number of cores / pairs | 2 wires / 1 pair |
| Wires | Copper, 0.25 mm² / AWG 24 |
| Wire colours | Red / green |
| Outer diameter | 8 mm |
| Outer sheath | PUR, purple |
| Shielding | Aluminium foil and tinned copper braiding |
| Halogen-free | Yes |
| FastConnect | No |
| Nominal impedance | 150 Ω in the 3-20 MHz band |
| Capacitance | Approximately 32 nF/km at 800 Hz between conductors |
| Loop resistance, maximum | 145 Ω/km |
| Attenuation at 4 MHz, maximum | 2.5 dB per 100 metres |
| Attenuation at 16 MHz, maximum | 4.9 dB / 100 m |
| Minimum bend radius | 65 mm for flexing applications |
| Operating temperature | -30 to +70 °C whilst in motion |
| Mass per unit length | 64 kg/km |
| Flame resistance | IEC 60332-1-2 |
| Sales unit | Metre |
| FOXON minimum order quantity | 10 m |
Selection and correct use
Is this cable intended for use in a power chain?
The cable is suitable for use in power chains and on repeatedly moving machine parts. The design must take into account the bending radius, temperature, speed, acceleration and travel distance. Torsional use is limited to operating conditions typical of cable loops in wind turbines; it does not constitute general approval for any robotic movement.
How do I order the required length?
We sell the cable by the metre and cut it to length. The minimum order is 10 metres. Enter the required length in metres in the ‘Quantity’ field, for example 25 for a length of 25 metres. We will confirm the availability and delivery method for the specific length before you place your order.
Is the cable halogen-free?
One pair of red and green conductors is protected by aluminium foil and a tinned copper braid. The PUR sheath is halogen-free, resistant to mineral oils and abrasion. The cable is flame-retardant in accordance with IEC 60332-1-2. This is not a power cable.
What bending radius should be used?
For applications involving movement, allow for a minimum bending radius of 65 mm and a temperature range of -30 to +70 °C. Route the cable through the chain without twisting it, ensuring adequate strain relief and allowing room for movement. The number of bending cycles depends on the specific operating conditions; the minimum bend radius alone is no guarantee of service life. For a design at this bending-radius limit, obtain manufacturer confirmation for the specific application.
Can the FastConnect stripping tool be used?
LAPP 2170222 is not a FastConnect version. To prepare the sheath and screening, select a tool and procedure suitable for its construction. The Siemens stripping tool for PROFIBUS FastConnect cannot be automatically recommended solely on the basis of the cable having the same diameter.
Why order from FOXON
We can help you select the cabling and accessories to suit your specific PROFIBUS installation. Please send us a layout diagram, a list of device designations and a description of the environment.
Selection for a specific route
We will review the cable routing, movement, temperature and requirements of the installation.
Cable and connectors
We will check the compatibility of the conductors, the shielding, the dimensions and the method of installation.
Preparing the cabling
We’ll help you choose the right tool and procedure for your specific connector.
PROFIBUS Diagnostics
We can help with signal measurement, termination and identifying the causes of communication failures.
Czech technical support
We will discuss the topology, environment and cable replacement procedure with regard to the machine operating conditions.
Delivery Confirmation
Before placing an order, we will confirm the specifications, quantity and delivery date.
Technical data sheets and installation documentation
In the ‘Downloads’ tab, you will find the current technical data sheet for the exact order number 2170222. The updated selection table sets out the conditions for assessing bending cycles in the power chain. An EU Declaration of Conformity is also attached.
Open downloadsTechnical specifications 2170222
UNITRONIC® BUS PB FD P 1X2X0,64
Identification and design
| Manufacturer | LAPP |
|---|---|
| Order number | 2170222 |
| Model designation | UNITRONIC® BUS PB FD P 1X2X0,64 |
| Uses | Moving applications, energy chains |
| Number of cores / pairs | 2 wires / 1 pair |
| Wires | Copper, 0.25 mm² / AWG 24 |
| Wire colours | Red / green |
| Outer diameter | 8 mm |
| Outer sheath | PUR, purple |
| Shielding | Aluminium foil and tinned copper braiding |
| Halogen-free | Yes |
| FastConnect | No |
Electrical specifications
| Nominal impedance | 150 Ω in the 3-20 MHz band |
|---|---|
| Capacitance | Approximately 32 nF/km at 800 Hz between conductors |
| Loop resistance, maximum | 145 Ω/km |
| Attenuation at 4 MHz, maximum | 2.5 dB per 100 metres |
| Attenuation at 16 MHz, maximum | 4.9 dB / 100 m |
Mechanical and operational data
| Minimum bend radius | 65 mm for flexing applications |
|---|---|
| Operating temperature | -30 to +70 °C whilst in motion |
| Mass per unit length | 64 kg/km |
| Flame resistance | IEC 60332-1-2 |
| Sales unit | Metre |
| FOXON minimum order quantity | 10 m |
Compatibility and preparation
LAPP 2170222 is not a FastConnect version. To prepare the sheath and screening, select a tool and procedure suitable for its construction. The Siemens stripping tool for PROFIBUS FastConnect cannot be automatically recommended solely on the basis of the cable having the same diameter.
When connecting, ensure that the stripped lengths and connection method comply with the specifications for the selected connector. In a standard PROFIBUS DP connection, A is the green wire and B is the red wire. The shield must make proper contact with the connector or the designated shielding element. After installation, check the wiring and network communication.
Use and delivery
The cable is suitable for use in power chains and on repeatedly moving machine parts. The design must take into account the bending radius, temperature, speed, acceleration and travel distance. Torsional use is limited to operating conditions typical of cable loops in wind turbines; it does not constitute general approval for any robotic movement.
We sell the cable by the metre and cut it to length. The minimum order is 10 metres. Enter the required length in metres in the ‘Quantity’ field, for example 25 for a length of 25 metres. We will confirm the availability and delivery method for the specific length before you place your order.
Choosing the right model
Is this cable intended for use in a power chain?
The cable is suitable for use in power chains and on repeatedly moving machine parts. The design must take into account the bending radius, temperature, speed, acceleration and travel distance. Torsional use is limited to operating conditions typical of cable loops in wind turbines; it does not constitute general approval for any robotic movement.
How do I order the required length?
We sell the cable by the metre and cut it to length. The minimum order is 10 metres. Enter the required length in metres in the ‘Quantity’ field, for example 25 for a length of 25 metres. We will confirm the availability and delivery method for the specific length before you place your order.
Is the cable halogen-free?
One pair of red and green conductors is protected by aluminium foil and a tinned copper braid. The PUR sheath is halogen-free, resistant to mineral oils and abrasion. The cable is flame-retardant in accordance with IEC 60332-1-2. This is not a power cable.
Installation and use
What bending radius should be used?
For applications involving movement, allow for a minimum bending radius of 65 mm and a temperature range of -30 to +70 °C. Route the cable through the chain without twisting it, ensuring adequate strain relief and allowing room for movement. The number of bending cycles depends on the specific operating conditions; the minimum bend radius alone is no guarantee of service life. For a design at this bending-radius limit, obtain manufacturer confirmation for the specific application.
Can the FastConnect stripping tool be used?
LAPP 2170222 is not a FastConnect version. To prepare the sheath and screening, select a tool and procedure suitable for its construction. The Siemens stripping tool for PROFIBUS FastConnect cannot be automatically recommended solely on the basis of the cable having the same diameter.
How long can a single segment be?
Design the segment length according to the network speed, the attenuation of the specific cable and the overall topology. Trailing cables have different electrical parameters to fixed standard cables. Therefore, do not automatically apply the maximum length table for a different type of cable. After modifying the network, we recommend verifying the signal and communication using the ProfiTrace2 tester.
How do you connect the red and green wires?
When connecting, ensure that the stripped lengths and connection method comply with the specifications for the selected connector. In a standard PROFIBUS DP connection, A is the green wire and B is the red wire. The shield must make proper contact with the connector or the designated shielding element. After installation, check the wiring and network communication.
Operations and technical consultancy
How do you terminate a PROFIBUS segment?
A segment is a section of the network in which the electrical signal is the same. Every PROFIBUS DP metallic segment must be properly terminated at both ends with a terminating resistor that is switched on and powered. It is the physical ends of the cable run that are decisive, not the lowest and highest device addresses.
Is 150 Ω the value of the terminating resistor?
No. 150 Ω is the nominal characteristic impedance of the cable within the specified frequency band. The PROFIBUS terminator is a powered resistor network as specified in the interface design. Do not replace it with a single 150 Ω resistor.
Will a new cable sort out all the network outages?
A new cable will help if the existing cable is damaged or unsuitable. However, reliable communication requires the correct connectors, powered terminations, shielding and topology. Check the cause of any outages by measuring the entire route.
Highlighted items are mandatory.