LAPP 2170222 - PROFIBUS DP trailing cable

LAPP 2170222 - PROFIBUS DP trailing cable


LAPPGROUP

LAPP 2170222 - PROFIBUS DP trailing cable, 1 pair 0.25 mm² / AWG 24, PUR, halogen-free, double-shielded, diameter 8 mm. Not FastConnect. Sold by the metre, minimum order 10 m. More

Code: 2170222

4 EUR excl. VAT (4,84 EUR Incl. VAT)
In stock
m
(330 m In stock)

Rezervace termínu

Get a quote
LAPPGROUP

LAPP 2170222 - PROFIBUS DP trailing cable, 1 pair 0.25 mm² / AWG 24, PUR, halogen-free, double-shielded, diameter 8 mm. Not FastConnect. Sold by the metre, minimum order 10 m. More

Code: 2170222

LAPP2170222
LAPP 2170222 - PROFIBUS DP cable

UNITRONIC® BUS PB FD P 1X2X0,64

Installation of PROFIBUS DP networks

PROFIBUS DP trailing cable

PUR · halogen-free · flexible applications

LAPP 2170222 UNITRONIC® BUS PB FD P is a shielded data cable designed for mobile PROFIBUS DP applications, energy chains and frequently moving machine parts. It features 1 pair of 0.25 mm² (AWG 24) copper conductors, double screening and a halogen-free, oil- and abrasion-resistant PUR sheath.

2170222PUR

Send the required length and installation method. We will check the suitable cable version and connectors.

Dynamic applicationsPower chains
8 mmOuter diameter of the cable
Halogen-free PURDouble shielding
From 10 mSold by the metre
Practical application

Use during the installation and maintenance of the network

The cable is suitable for use in power chains and on repeatedly moving machine parts. The design must take into account the bending radius, temperature, speed, acceleration and travel distance. Torsional use is limited to operating conditions typical of cable loops in wind turbines; it does not constitute general approval for any robotic movement.

Ordering a cable

Sold by the metre, in lengths of 10 metres or more

We sell the cable by the metre and cut it to length. The minimum order is 10 metres. Enter the required length in metres in the ‘Quantity’ field, for example 25 for a length of 25 metres. We will confirm the availability and delivery method for the specific length before you place your order.

We supply the cable without connectors fitted. We will confirm the length, packaging and availability of the specific quantity in our quotation.

Materials

Cable construction and double shielding

One pair of red and green conductors is protected by aluminium foil and a tinned copper braid. The PUR sheath is halogen-free, resistant to mineral oils and abrasion. The cable is flame-retardant in accordance with IEC 60332-1-2. This is not a power cable.

LAPP 2170222 - PROFIBUS DP cable - detail 2
LAPP 2170222 - product details
Installation proposal

Bend radius and operating conditions

For applications involving movement, allow for a minimum bending radius of 65 mm and a temperature range of -30 to +70 °C. Route the cable through the chain without twisting it, ensuring adequate strain relief and allowing room for movement. The number of bending cycles depends on the specific operating conditions; the minimum bend radius alone is no guarantee of service life. For a design at this bending-radius limit, obtain manufacturer confirmation for the specific application.

You will also find the design data for moving applications amongst the downloadable files. The indicative service life given in the selection table applies only to the specified operating conditions.

FastConnect and connectivity

Cable end preparation and connector assembly

LAPP 2170222 is not a FastConnect version. To prepare the sheath and screening, select a tool and procedure suitable for its construction. The Siemens stripping tool for PROFIBUS FastConnect cannot be automatically recommended solely on the basis of the cable having the same diameter.

When connecting, ensure that the stripped lengths and connection method comply with the specifications for the selected connector. In a standard PROFIBUS DP connection, A is the green wire and B is the red wire. The shield must make proper contact with the connector or the designated shielding element. After installation, check the wiring and network communication.

PROFIBUS topology

Cable length and segment termination

Design the segment length according to the network speed, the attenuation of the specific cable and the overall topology. Trailing cables have different electrical parameters to fixed standard cables. Therefore, do not automatically apply the maximum length table for a different type of cable. After modifying the network, we recommend verifying the signal and communication using the ProfiTrace2 tester.

A segment is a section of the network in which the electrical signal is the same. Every PROFIBUS DP metallic segment must be properly terminated at both ends with a terminating resistor that is switched on and powered. It is the physical ends of the cable run that are decisive, not the lowest and highest device addresses.

LAPP / UNITRONIC® BUS PB FD P 1X2X0,64

Technical specifications 2170222

ManufacturerLAPP
Order number2170222
Model designationUNITRONIC® BUS PB FD P 1X2X0,64
UsesMoving applications, energy chains
Number of cores / pairs2 wires / 1 pair
WiresCopper, 0.25 mm² / AWG 24
Wire coloursRed / green
Outer diameter8 mm
Outer sheathPUR, purple
ShieldingAluminium foil and tinned copper braiding
Halogen-freeYes
FastConnectNo
Nominal impedance150 Ω in the 3-20 MHz band
CapacitanceApproximately 32 nF/km at 800 Hz between conductors
Loop resistance, maximum145 Ω/km
Attenuation at 4 MHz, maximum2.5 dB per 100 metres
Attenuation at 16 MHz, maximum4.9 dB / 100 m
Minimum bend radius65 mm for flexing applications
Operating temperature-30 to +70 °C whilst in motion
Mass per unit length64 kg/km
Flame resistanceIEC 60332-1-2
Sales unitMetre
FOXON minimum order quantity10 m
Practical questions

Selection and correct use

Is this cable intended for use in a power chain?

The cable is suitable for use in power chains and on repeatedly moving machine parts. The design must take into account the bending radius, temperature, speed, acceleration and travel distance. Torsional use is limited to operating conditions typical of cable loops in wind turbines; it does not constitute general approval for any robotic movement.

How do I order the required length?

We sell the cable by the metre and cut it to length. The minimum order is 10 metres. Enter the required length in metres in the ‘Quantity’ field, for example 25 for a length of 25 metres. We will confirm the availability and delivery method for the specific length before you place your order.

Is the cable halogen-free?

One pair of red and green conductors is protected by aluminium foil and a tinned copper braid. The PUR sheath is halogen-free, resistant to mineral oils and abrasion. The cable is flame-retardant in accordance with IEC 60332-1-2. This is not a power cable.

What bending radius should be used?

For applications involving movement, allow for a minimum bending radius of 65 mm and a temperature range of -30 to +70 °C. Route the cable through the chain without twisting it, ensuring adequate strain relief and allowing room for movement. The number of bending cycles depends on the specific operating conditions; the minimum bend radius alone is no guarantee of service life. For a design at this bending-radius limit, obtain manufacturer confirmation for the specific application.

Can the FastConnect stripping tool be used?

LAPP 2170222 is not a FastConnect version. To prepare the sheath and screening, select a tool and procedure suitable for its construction. The Siemens stripping tool for PROFIBUS FastConnect cannot be automatically recommended solely on the basis of the cable having the same diameter.

PROFIBUS Technical Support

Why order from FOXON

We can help you select the cabling and accessories to suit your specific PROFIBUS installation. Please send us a layout diagram, a list of device designations and a description of the environment.

Selection for a specific route

We will review the cable routing, movement, temperature and requirements of the installation.

Cable and connectors

We will check the compatibility of the conductors, the shielding, the dimensions and the method of installation.

Preparing the cabling

We’ll help you choose the right tool and procedure for your specific connector.

PROFIBUS Diagnostics

We can help with signal measurement, termination and identifying the causes of communication failures.

Czech technical support

We will discuss the topology, environment and cable replacement procedure with regard to the machine operating conditions.

Delivery Confirmation

Before placing an order, we will confirm the specifications, quantity and delivery date.

Correct cablingCable routing, movement and construction
Fitting connectorsPreparation, shielding and termination
Network measurementSignal and communication quality
Documentation

Technical data sheets and installation documentation

In the ‘Downloads’ tab, you will find the current technical data sheet for the exact order number 2170222. The updated selection table sets out the conditions for assessing bending cycles in the power chain. An EU Declaration of Conformity is also attached.

Open downloads
LAPP

Technical specifications 2170222

UNITRONIC® BUS PB FD P 1X2X0,64

Identification and design

ManufacturerLAPP
Order number2170222
Model designationUNITRONIC® BUS PB FD P 1X2X0,64
UsesMoving applications, energy chains
Number of cores / pairs2 wires / 1 pair
WiresCopper, 0.25 mm² / AWG 24
Wire coloursRed / green
Outer diameter8 mm
Outer sheathPUR, purple
ShieldingAluminium foil and tinned copper braiding
Halogen-freeYes
FastConnectNo

Electrical specifications

Nominal impedance150 Ω in the 3-20 MHz band
CapacitanceApproximately 32 nF/km at 800 Hz between conductors
Loop resistance, maximum145 Ω/km
Attenuation at 4 MHz, maximum2.5 dB per 100 metres
Attenuation at 16 MHz, maximum4.9 dB / 100 m

Mechanical and operational data

Minimum bend radius65 mm for flexing applications
Operating temperature-30 to +70 °C whilst in motion
Mass per unit length64 kg/km
Flame resistanceIEC 60332-1-2
Sales unitMetre
FOXON minimum order quantity10 m
Installation

Compatibility and preparation

LAPP 2170222 is not a FastConnect version. To prepare the sheath and screening, select a tool and procedure suitable for its construction. The Siemens stripping tool for PROFIBUS FastConnect cannot be automatically recommended solely on the basis of the cable having the same diameter.

When connecting, ensure that the stripped lengths and connection method comply with the specifications for the selected connector. In a standard PROFIBUS DP connection, A is the green wire and B is the red wire. The shield must make proper contact with the connector or the designated shielding element. After installation, check the wiring and network communication.

Installation proposal

Use and delivery

The cable is suitable for use in power chains and on repeatedly moving machine parts. The design must take into account the bending radius, temperature, speed, acceleration and travel distance. Torsional use is limited to operating conditions typical of cable loops in wind turbines; it does not constitute general approval for any robotic movement.

We sell the cable by the metre and cut it to length. The minimum order is 10 metres. Enter the required length in metres in the ‘Quantity’ field, for example 25 for a length of 25 metres. We will confirm the availability and delivery method for the specific length before you place your order.

FAQ - 2170222

Choosing the right model

Is this cable intended for use in a power chain?

The cable is suitable for use in power chains and on repeatedly moving machine parts. The design must take into account the bending radius, temperature, speed, acceleration and travel distance. Torsional use is limited to operating conditions typical of cable loops in wind turbines; it does not constitute general approval for any robotic movement.

How do I order the required length?

We sell the cable by the metre and cut it to length. The minimum order is 10 metres. Enter the required length in metres in the ‘Quantity’ field, for example 25 for a length of 25 metres. We will confirm the availability and delivery method for the specific length before you place your order.

Is the cable halogen-free?

One pair of red and green conductors is protected by aluminium foil and a tinned copper braid. The PUR sheath is halogen-free, resistant to mineral oils and abrasion. The cable is flame-retardant in accordance with IEC 60332-1-2. This is not a power cable.

Installation

Installation and use

What bending radius should be used?

For applications involving movement, allow for a minimum bending radius of 65 mm and a temperature range of -30 to +70 °C. Route the cable through the chain without twisting it, ensuring adequate strain relief and allowing room for movement. The number of bending cycles depends on the specific operating conditions; the minimum bend radius alone is no guarantee of service life. For a design at this bending-radius limit, obtain manufacturer confirmation for the specific application.

Can the FastConnect stripping tool be used?

LAPP 2170222 is not a FastConnect version. To prepare the sheath and screening, select a tool and procedure suitable for its construction. The Siemens stripping tool for PROFIBUS FastConnect cannot be automatically recommended solely on the basis of the cable having the same diameter.

How long can a single segment be?

Design the segment length according to the network speed, the attenuation of the specific cable and the overall topology. Trailing cables have different electrical parameters to fixed standard cables. Therefore, do not automatically apply the maximum length table for a different type of cable. After modifying the network, we recommend verifying the signal and communication using the ProfiTrace2 tester.

How do you connect the red and green wires?

When connecting, ensure that the stripped lengths and connection method comply with the specifications for the selected connector. In a standard PROFIBUS DP connection, A is the green wire and B is the red wire. The shield must make proper contact with the connector or the designated shielding element. After installation, check the wiring and network communication.

Maintenance

Operations and technical consultancy

How do you terminate a PROFIBUS segment?

A segment is a section of the network in which the electrical signal is the same. Every PROFIBUS DP metallic segment must be properly terminated at both ends with a terminating resistor that is switched on and powered. It is the physical ends of the cable run that are decisive, not the lowest and highest device addresses.

Is 150 Ω the value of the terminating resistor?

No. 150 Ω is the nominal characteristic impedance of the cable within the specified frequency band. The PROFIBUS terminator is a powered resistor network as specified in the interface design. Do not replace it with a single 150 Ω resistor.

Will a new cable sort out all the network outages?

A new cable will help if the existing cable is damaged or unsuitable. However, reliable communication requires the correct connectors, powered terminations, shielding and topology. Check the cause of any outages by measuring the entire route.