- Machine data collection
- OPC UA / MQTT Sensors
- Ethernet Thermometer 8x Pt100/Pt1000 sensors via terminal block, Modbus TCP, REST, MQTT, OPC UA
Ethernet Thermometer 8x Pt100/Pt1000 sensors via terminal block, Modbus TCP, REST, MQTT, OPC UA
Industrial module for remote monitoring and data acquisition of eight temperatures, measured via 8x independent Pt100 W&T sensors -50C...180C, via a measuring input with a range of -200C...650C each. Sensor connection via terminal block, cable length 2m to sensor, can be extended. Temperature data is also provided via OPC UA/DA, REST, MQTT, Modbus TCP or Web Server. Built-in data logger for archiving data to FTP, Excel, ODBC, W&T cloud or custom memory with min 16 weeks and max 20 years, storage in 15,30sec or 1,5,15,60min increments. Alarm system with email notification, automatic control of outputs according to input. Data readout after 4sec, power supply 12-48VDC or PoE, DIN mounting. More
Code: 57778
Industrial module for remote monitoring and data acquisition of eight temperatures, measured via 8x independent Pt100 W&T sensors -50C...180C, via a measuring input with a range of -200C...650C each. Sensor connection via terminal block, cable length 2m to sensor, can be extended. Temperature data is also provided via OPC UA/DA, REST, MQTT, Modbus TCP or Web Server. Built-in data logger for archiving data to FTP, Excel, ODBC, W&T cloud or custom memory with min 16 weeks and max 20 years, storage in 15,30sec or 1,5,15,60min increments. Alarm system with email notification, automatic control of outputs according to input. Data readout after 4sec, power supply 12-48VDC or PoE, DIN mounting. More
Code: 57778
Temperature measurement via Ethernet: 8× Pt100/Pt1000
The W&T 57778 connects Pt100 or Pt1000 resistance temperature sensors to an Ethernet network. It displays the temperature in a web browser, stores historical data and provides measured data via OPC UA, MQTT, REST or Modbus TCP.
Do you need to select or order the W&T 57778?
Please send us the required quantity and a description of the wiring configuration. We will check availability and suitable accessories.
Usage
It is used to monitor temperatures in technical rooms, switchboards and industrial equipment. The web-based display of data trends and customisable alerts facilitate long-term monitoring without the need for a separate computer to carry out the measurements.
Technical specifications for W&T 57778
| Temperature sensor | 8× Pt100/Pt1000 inputs on a screw terminal block W&T probe cable: 2 m, can be extended depending on the connection Probe protection rating: IP67 |
|---|---|
| Network interface | 10/100BaseT, auto-detection / Auto-MDIX RJ45 IPv6 on request |
| Galvanic isolation | Network interface section: min. 1500 V |
| Power supply | Power-over-Ethernet (PoE) or 24–48 V DC (±10 %) |
| Power connection | Screw-type terminal block |
| Current consumption | PoE Class 1 (0.44–3.84 W) max. 60 mA at 24 V DC max. 40 mA at 48 V DC |
| Signalling | 1 Power LED 2× network status LEDs 4 LEDs for status and faults |
| Sensor | 8× Pt100/Pt1000 connections: two-wire, three-wire or four-wire |
| Measuring range | W&T sensor: -50 °C to 180 °C PT100/PT1000 measurement input: -200 °C to 650 °C |
| Resolution | 1/10 °C |
| Measurement unit error | ±0.3 °C, ±0.2 % |
| Class A Pt100/Pt1000 sensor error | ±0.15 °C, ±0.2 % |
| Measurement period | 4 seconds |
| Save interval | 15 s, 30 s, 1 min, 5 min, 15 min, 60 min |
| History capacity (4 MB memory) | min. 4 weeks, max. 20 years |
| Housing and mounting | Compact plastic housing for DIN rail mounting 90 × 107 × 59 mm (L × W × H) |
| Degree of protection | IP20 |
| Weight | approx. 200 g |
| Ambient temperature | Storage: -40 to +70 °C Operating temperature with spacing between devices: 0 to +60 °C Operating temperature when installed side by side without spacing: 0 to +50 °C |
| Permissible relative humidity | 0 to 95 per cent RH, non-condensing |
| Operating ambient temperature | 0 to +60 °C |
| Contents of the delivery | 1x web thermometer 8x 1x Pt100 sensor, 2 m, IP67 1× quick start guide |
Sensors, ranges and temperature recording
- Eight measurement inputs on the terminal block. The standard supply includes only one Pt100 sensor with a 2 m cable and IP67 protection; additional sensors must be ordered separately.
- The measurement input covers -200 to +650 °C. The supplied W&T sensor is rated for -50 to +180 °C. The usable range of the entire measurement is limited by the specific sensor and its design.
- Two-wire, three-wire and four-wire Pt100/Pt1000 connections are supported. The selected sensor type and number of wires must correspond to the input settings and wiring.
- The resolution is 0.1 °C and measurements are updated every 4 seconds. The recording interval can be selected independently: 15 or 30 seconds, or 1, 5, 15 or 60 minutes.
- Up to 12 customisable alerts are available, along with email, SNMP and other network services. The length of the history retained depends on the number of measured channels and the set interval.
Commissioning and accessories
Select sensors according to the required temperature and environment. Check the wiring, shield connection and Pt100/Pt1000 settings. After setting the IP address, select the units, logging interval and alarm limits. The IP20 rating specified applies to the network module itself, not automatically to the probe.
Contents of the delivery
- 1x web thermometer 8x
- 1x Pt100 sensor, 2 m, IP67
- 1× quick start guide
Frequently Asked Questions
Does the supplied sensor measure the full range from -200 to +650 °C?
No. This range applies to the measurement input. The supplied W&T sensor has a range of -50 to +180 °C. A suitable, compatible sensor is required for a different range.
How many sensors are included in the delivery?
Eight measurement inputs on the terminal block. The standard supply includes only one Pt100 sensor with a 2 m cable and IP67 protection; additional sensors must be ordered separately.
Is resolution the same as accuracy?
No. A resolution of 0.1 °C determines the smallest displayed increment. The total measurement error includes the unit of measurement, the sensor and the effect of the wiring; the individual values are listed in the technical table.
Why buy from FOXON
W&T distributor
We are a distributor of W&T products. We supply new original products with a warranty.
Stock availability and delivery
We check current availability from our own and partner warehouses. Before you order, we confirm the price and possible delivery date for the specific model.
Product selection and technical advice
We help you choose the model, power supply and accessories to suit your connections and communication requirements.
Solution design and configuration
We discuss the connections and application requirements. Where needed, we propose a suitable setup and agree on the scope of assistance with configuration and commissioning.
Documentation and technical consultancy
Technical data and documentation W&T 57778
Manuals, firmware and tools for this model are also available in the Downloads tab. We can help with product selection and configuration according to your connections and communication requirements.
Do you need to select or order the W&T 57778?
Please send us the required quantity and a description of the wiring configuration. We will check availability and suitable accessories.
Diagrams and illustrations

Further related links
Technical specifications for W&T 57778
| Temperature sensor | 8× Pt100/Pt1000 inputs on a screw terminal block W&T probe cable: 2 m, can be extended depending on the connection Probe protection rating: IP67 |
|---|---|
| Network interface | 10/100BaseT, auto-detection / Auto-MDIX RJ45 IPv6 on request |
| Galvanic isolation | Network interface section: min. 1500 V |
| Power supply | Power-over-Ethernet (PoE) or 24–48 V DC (±10 %) |
| Power connection | Screw-type terminal block |
| Current consumption | PoE Class 1 (0.44–3.84 W) max. 60 mA at 24 V DC max. 40 mA at 48 V DC |
| Signalling | 1 Power LED 2× network status LEDs 4 LEDs for status and faults |
| Sensor | 8× Pt100/Pt1000 connections: two-wire, three-wire or four-wire |
| Measuring range | W&T sensor: -50 °C to 180 °C PT100/PT1000 measurement input: -200 °C to 650 °C |
| Resolution | 1/10 °C |
| Measurement unit error | ±0.3 °C, ±0.2 % |
| Class A Pt100/Pt1000 sensor error | ±0.15 °C, ±0.2 % |
| Measurement period | 4 seconds |
| Save interval | 15 s, 30 s, 1 min, 5 min, 15 min, 60 min |
| History capacity (4 MB memory) | min. 4 weeks, max. 20 years |
| Housing and mounting | Compact plastic housing for DIN rail mounting 90 × 107 × 59 mm (L × W × H) |
| Degree of protection | IP20 |
| Weight | approx. 200 g |
| Ambient temperature | Storage: -40 to +70 °C Operating temperature with spacing between devices: 0 to +60 °C Operating temperature when installed side by side without spacing: 0 to +50 °C |
| Permissible relative humidity | 0 to 95 per cent RH, non-condensing |
| Operating ambient temperature | 0 to +60 °C |
| Contents of the delivery | 1x web thermometer 8x 1x Pt100 sensor, 2 m, IP67 1× quick start guide |

VIDEO: Easily Collect Machine Data via OPC UA & MQTT
At the beginning of 2024 we introduced a new product from the German manufacturer of industrial modules W&T to the Czech market. Check out our short videos to see how easy it is to set up and use W&T sensors and digital and analogue inputs and outputs for data acquisition using OPC UA and MQTT communications.
Highlighted items are mandatory.