Converter OPC UA Server / PROFINET Slave - HD67B46-B2
Converter OPC UA Server / PROFINET Slave - HD67B46-B2
The ADFweb HD67B46-B2 connects a PROFINET system to an OPC UA client. It operates as a Slave on PROFINET and makes data available through its OPC UA Server. More
Code: HD67B46-B2
The ADFweb HD67B46-B2 connects a PROFINET system to an OPC UA client. It operates as a Slave on PROFINET and makes data available through its OPC UA Server. More
Code: HD67B46-B2
ADFweb HD67B46-B2
OPC UA Server / PROFINET Slave
The ADFweb HD67B46-B2 connects a PROFINET system to an OPC UA client. It operates as a Slave on PROFINET and makes data available through its OPC UA Server.
We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.
Converter applications
It allows an OPC UA Client application to access data that the controller passes to the gateway over PROFINET. The capacity is up to 1,500 bytes for reading and 1,500 bytes for writing.
Technical specifications HD67B46-B2
| Order code | HD67B46-B2 |
|---|---|
| Protocol connection | OPC UA Server / PROFINET Slave |
| Converter roles | OPC UA Server; PROFINET Slave |
| Interfaces and ports | Ethernet RJ45 |
| Data capacity | 1500 bytes in each direction |
| Power supply | Confirm against the label and hardware version before ordering |
| Power consumption at 24 V DC | 4 W |
| Operating temperature | -40 °C to +85 °C |
| Mounting | 35 mm DIN rail |
| Dimensions of the version shown (D × W × H) | 60 × 35 × 95 mm |
| Device weight | approximately 200 g |
| Configuration software | SW67B46 |
We will confirm the supply range for this model against the specific hardware version. Always check the device label before connecting the power supply.
Communication and configuration
In SW67B46, configure PROFINET, OPC UA and the variables accessible to the client. The corresponding data areas must also be prepared in the PROFINET controller project.
This model is not a PROFINET Master and does not independently poll arbitrary PLCs. We will confirm the hardware version and number of physical ports in the quotation; check OPC UA security settings against the specific firmware.
Supply and accessories
Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.
Documentation and software
Diagrams and hardware version


The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.
Frequently asked questions
Is knowing the two protocols enough?
The device roles, physical interfaces and data to be transferred must also be checked. This model is not a PROFINET Master and does not independently poll arbitrary PLCs. We will confirm the hardware version and number of physical ports in the quotation; check OPC UA security settings against the specific firmware.
How is this converter configured?
In SW67B46, configure PROFINET, OPC UA and the variables accessible to the client. The corresponding data areas must also be prepared in the PROFINET controller project.
What information should I send to check the selection?
Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.
FOXON support with selection and ordering
Selection based on your devices
We will review the specific connection, communication roles and required data.
Availability check
Before you place an order, we will confirm current availability and the possible delivery date.
Documentation for the exact order code
We select the documentation and configuration tool using the complete order code.
Accessories for your installation
We will include the requested accessories in the quotation to suit the connection arrangement.
Choosing the correct version
Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.
This model is not a PROFINET Master and does not independently poll arbitrary PLCs. We will confirm the hardware version and number of physical ports in the quotation; check OPC UA security settings against the specific firmware.
Converter enquiry HD67B46-B2
Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.
Request the converterTechnical specifications HD67B46-B2
| Order code | HD67B46-B2 |
|---|---|
| Protocol connection | OPC UA Server / PROFINET Slave |
| Converter roles | OPC UA Server; PROFINET Slave |
| Interfaces and ports | Ethernet RJ45 |
| Data capacity | 1500 bytes in each direction |
| Power supply | Confirm against the label and hardware version before ordering |
| Power consumption at 24 V DC | 4 W |
| Operating temperature | -40 °C to +85 °C |
| Mounting | 35 mm DIN rail |
| Dimensions of the version shown (D × W × H) | 60 × 35 × 95 mm |
| Device weight | approximately 200 g |
| Configuration software | SW67B46 |
We will confirm the supply range for this model against the specific hardware version. Always check the device label before connecting the power supply.