The ADFweb HD67E01-5-A1 connects serial Modbus RTU Slave devices to an EtherCAT control system. It controls reads and writes as a Modbus Master over RS485 and operates as an EtherCAT Slave. More

Code: HD67E01-5-A1

249 EUR excl. VAT (301,29 EUR Incl. VAT)
Delivery 3-8 days
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote
ADFweb

The ADFweb HD67E01-5-A1 connects serial Modbus RTU Slave devices to an EtherCAT control system. It controls reads and writes as a Modbus Master over RS485 and operates as an EtherCAT Slave. More

Code: HD67E01-5-A1

ADFweb HD67E01-5-A1

EtherCAT Slave / Modbus RTU Master RS485

The ADFweb HD67E01-5-A1 connects serial Modbus RTU Slave devices to an EtherCAT control system. It controls reads and writes as a Modbus Master over RS485 and operates as an EtherCAT Slave.

We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.

Request the converter
EtherCAT Slave / Modbus RTU Master RS485Protocol connection
35 mm DIN railHardware version
SW67E01Configuration tool

Converter applications

Use it to integrate serial Modbus devices into an EtherCAT Master application. The converter reads or writes configured Modbus registers and maps them to EtherCAT process data.

Technical specifications HD67E01-5-A1

Order codeHD67E01-5-A1
Protocol connectionEtherCAT Slave / Modbus RTU Master RS485
Converter rolesEtherCAT Slave; Modbus RTU Master over RS485
Interfaces and ports2× EtherCAT RJ45 (IN/OUT); RS485; Ethernet RJ45 for configuration
Power supply8-24 V AC / 12-35 V DC
Consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)120 × 23 × 107 mm
Device weightapproximately 200 g
Configuration softwareSW67E01

For an older device, check the hardware version and connections against its label.

Communication and configuration

In SW67E01, configure RS485 settings, Modbus requests and EtherCAT variables for both transfer directions. The software exports an ESI file for configuring the EtherCAT Master.

The -5-A1 suffix identifies the RS485 serial version. Its Ethernet port is used for configuration and updates; this model does not convert Modbus TCP. Distinguish the EtherCAT IN/OUT ports from configuration Ethernet.

Supply and accessories

Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.

Documentation and software

Diagrams and hardware version

Dimensional drawing of the version shown - HD67E01-5-A1
Dimensional drawing of the version shown - HD67E01-5-A1

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.

Frequently asked questions

Is knowing the two protocols enough?

The device roles, physical interfaces and data to be transferred must also be checked. The -5-A1 suffix identifies the RS485 serial version. Its Ethernet port is used for configuration and updates; this model does not convert Modbus TCP. Distinguish the EtherCAT IN/OUT ports from configuration Ethernet.

How is this converter configured?

In SW67E01, configure RS485 settings, Modbus requests and EtherCAT variables for both transfer directions. The software exports an ESI file for configuring the EtherCAT Master.

What information should I send to check the selection?

Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.

FOXON support with selection and ordering

Selection based on your devices

We will review the specific connection, communication roles and required data.

Availability check

Before you place an order, we will confirm current availability and the possible delivery date.

Documentation for the exact order code

We select the documentation and configuration tool using the complete order code.

Accessories for your installation

We will include the requested accessories in the quotation to suit the connection arrangement.

Choosing the correct version

Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.

The -5-A1 suffix identifies the RS485 serial version. Its Ethernet port is used for configuration and updates; this model does not convert Modbus TCP. Distinguish the EtherCAT IN/OUT ports from configuration Ethernet.

Converter enquiry HD67E01-5-A1

Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.

Request the converter

Technical specifications HD67E01-5-A1

Order codeHD67E01-5-A1
Protocol connectionEtherCAT Slave / Modbus RTU Master RS485
Converter rolesEtherCAT Slave; Modbus RTU Master over RS485
Interfaces and ports2× EtherCAT RJ45 (IN/OUT); RS485; Ethernet RJ45 for configuration
Power supply8-24 V AC / 12-35 V DC
Consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)120 × 23 × 107 mm
Device weightapproximately 200 g
Configuration softwareSW67E01

For an older device, check the hardware version and connections against its label.