6SE6420-2UC23-0CA1

6SE6420-2UC23-0CA1

Sales, Repair, Purchase

SIEMENS

MICROMASTER 420 without filter 200-240 V 1/3 AC+10/-10% 47-63 Hz constant torque 3 kW overload 150% for 60 s square-law torque 3 kW 245x 185x 195 (HxWxD) degree of protection IP20 ambient temperature -10+50 °C without AOP/BOP More

Code: 6SE6420-2UC23-0CA1

Variant does not exist

Rezervace termínu

Get a quote
SIEMENS

MICROMASTER 420 without filter 200-240 V 1/3 AC+10/-10% 47-63 Hz constant torque 3 kW overload 150% for 60 s square-law torque 3 kW 245x 185x 195 (HxWxD) degree of protection IP20 ambient temperature -10+50 °C without AOP/BOP More

Code: 6SE6420-2UC23-0CA1

Repair of the part

Name Code Delivery Warranty Price excl. VAT
Complete part repair 6SE6420-2UC23-0CA1 O 3-6 weeks 24 months On request Enquire a repair

6SE6420-2UC23-0CA1 – MICROMASTER 420

MICROMASTER 420.

Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.

Request a quote for purchase or repair
13.6 ARated output current
Mains operating voltage 1 AC 200 V to 240 VCatalog input voltage and supply phases
3.0 kWRated motor power

Application and selection

Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product. Distinguish rated and peak current and the loading conditions stated with each value. Where LO and HO are listed, they refer to different overload conditions. Check the Control Unit, motor, cooling and wiring of the original drive.

Technical specifications

ManufacturerSiemens
Order number6SE6420-2UC23-0CA1
Catalog input voltage and supply phasesMains operating voltage 1 AC 200 V to 240 V
Rated motor power3.0 kW
Rated output current13.6 A
Rated input current35.5 A; at 240 V or 400 V, supply short-circuit voltage 2%, without line commutating choke
Frame sizeC
Integrated line filterNo
Catalog input voltage and supply phasesMains operating voltage 3 AC 200 V to 240 V
Rated input current15.6 A; at 240 V or 400 V, supply short-circuit voltage 2%, without line commutating choke
Product descriptionMICROMASTER 420 without filter 200-240 V 1/3 AC+10/-10% 47-63 Hz constant torque 3 kW overload 150% for 60 s square-law torque 3 kW 245x 185x 195 (HxWxD) degree of protection IP20 ambient temperature -10+50 °C without AOP/BOP
Dimensions H x W x D245x 185x 195 mm
Degree of protectionIP20

Loading, cooling and connections

  • Catalog input voltage and supply phases: Mains operating voltage 1 AC 200 V to 240 V
  • Rated output current: 13.6 A
  • Rated input current: 35.5 A; at 240 V or 400 V, supply short-circuit voltage 2%, without line commutating choke
  • Integrated line filter: No
  • Catalog input voltage and supply phases: Mains operating voltage 3 AC 200 V to 240 V
  • Rated input current: 15.6 A; at 240 V or 400 V, supply short-circuit voltage 2%, without line commutating choke

Scope of supply

We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.

Frequently asked questions

Is the same product family enough to identify a replacement?

The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.

What information is needed to check connections and accessories?

Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.

Can you assess a faulty part?

Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.

Why buy from FOXON

1

Replacement part availability

We will check current part availability and confirm the possible delivery date before you order.

2

New original and refurbished parts

We will specify the available version and condition of the particular unit in the quotation.

3

Parts with a warranty

We will confirm the warranty period according to the part condition and specific quotation.

4

Diagnostics and repairs

For a faulty unit, we will check the options for diagnostics and professional repair.

More than 3,500customers
We deliver tomore than 100 countries
Express delivery?We will check. Contact us now.

Part conditions available for sale

Part conditions and warranty
  • New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
  • New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
  • New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
  • New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
  • Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
  • Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
  • Used (U): Functional used part. 3-month warranty.

Sales, repairs and buyback of automation parts

We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.

More about parts sales, repairs and buyback

Need to buy or repair this part?

Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.

Request a quote for purchase or repair