from 329,12 EUR Incl. VAT
6ES7431-1KF00-0AB0, repair and sale of PLC / CNC SIEMENS
6ES7431-1KF00-0AB0, repair and sale of PLC / CNC SIEMENS
SIMATIC S7-400, SM 431 ANALOG INPUT MODULE OPTIC. ISOLATED, 8 AI, 13 BIT RESOLUTION, U/I/RESIST. More
Code: 6ES7431-1KF00-0AB0
SIMATIC S7-400, SM 431 ANALOG INPUT MODULE OPTIC. ISOLATED, 8 AI, 13 BIT RESOLUTION, U/I/RESIST. More
Code: 6ES7431-1KF00-0AB0
Part Sales 4
| Condition | Code | Warranty | Availability |
Delivery Express? | Price excl. VAT | |
|---|---|---|---|---|---|---|
| New in sealed box (NC) | 6ES7431-1KF00-0AB0 NC | 12/24 months | In external stock 8 pcs |
Within 2-4 days / Express
|
On request
|
|
| New without box (NW) | 6ES7431-1KF00-0AB0 NW | 12/24 months | In external stock 1 pcs |
Within 2-4 days / Express
|
On request
|
|
| Refurbished (R) | 6ES7431-1KF00-0AB0 R | 12/24 months | In external stock 112 pcs |
Within 2-4 days / Express
|
On request
|
|
| Used (U) | 6ES7431-1KF00-0AB0 U | 3 months | In stock |
On request
|
Repair of the part
| Name | Code | Delivery | Warranty | Price excl. VAT | |
|---|---|---|---|---|---|
| Complete part repair | 6ES7431-1KF00-0AB0 O | 3-6 weeks | 24 months | On request | Enquire a repair |
6ES7431-1KF00-0AB0 – SM 431
SIMATIC S7-400, analog input SM 431, isolated 8 AI, resolution 13 bit, voltage/current/resistance
Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.
Application and selection
Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.
Technical specifications
| Manufacturer | Siemens |
|---|---|
| Order number | 6ES7431-1KF00-0AB0 |
| Supply voltage / Load voltage L+ / Rated value (DC) | not necessary |
| Input current / from backplane bus 5 V DC, max. | 350 mA |
| Power loss / Power loss, typ. | 1.8 W |
| Analog inputs / Number of analog inputs | 8 |
| Analog inputs / For voltage/current measurement | 8 |
| Analog inputs / For resistance measurement | 4 |
| Analog inputs / permissible input voltage for voltage input (destruction limit), | 50 V |
| Analog inputs / permissible input current for current input (destruction limit), | 50 mA; 40 mA continuous |
| Analog inputs / Constant measurement current for resistance-type transmitter, | 1.67 mA |
| Analog inputs / Input ranges / Voltage | Yes |
| Analog inputs / Input ranges / Current | Yes |
| Analog inputs / Input ranges / Thermocouple | No |
| Analog inputs / Input ranges / Resistance thermometer | No |
| Analog inputs / Input ranges / Resistance | Yes |
| Analog inputs / Input ranges (rated values), voltages / 1 V to 5 V | Yes |
| Analog inputs / Input ranges (rated values), voltages / Input resistance (1 V to 5 V) | 200 kΩ |
| Analog inputs / Input ranges (rated values), voltages / -1 V to +1 V | Yes |
| Analog inputs / Input ranges (rated values), voltages / Input resistance (-1 V to +1 V) | 200 kΩ |
| Analog inputs / Input ranges (rated values), voltages / -10 V to +10 V | Yes |
| Analog inputs / Input ranges (rated values), voltages / Input resistance (-10 V to +10 V) | 200 kΩ |
| Analog inputs / Input ranges (rated values), currents / -20 mA to +20 mA | Yes |
| Analog inputs / Input ranges (rated values), currents / Input resistance (-20 mA to +20 mA) | 80 Ω |
| Analog inputs / Input ranges (rated values), currents / 4 mA to 20 mA | Yes |
| Analog inputs / Input ranges (rated values), currents / Input resistance (4 mA to 20 mA) | 80 Ω |
| Analog inputs / Input ranges (rated values), resistors / 0 to 600 ohms | Yes |
| Analog inputs / Input ranges (rated values), resistors / Input resistance (0 to 600 ohms) | usable up to 500 ohms |
| Analog inputs / Cable length / shielded, max. | 200 m |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max. | 13 bit |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Integration time, parameterizable | Yes |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Basic conversion time (ms) | 23 / 25 ms |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Integration time (ms) | 16,7 / 20 ms |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Interference voltage suppression for interference | 50 / 60 Hz |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Basic execution time of the module (all channels | 200 ms; 184 / 200 ms |
| Encoder / Connection of signal encoders / for voltage measurement | Yes; possible |
| Encoder / Connection of signal encoders / for current measurement as 2-wire transducer | Yes; with external transmitter supply |
| Encoder / Connection of signal encoders / for current measurement as 4-wire transducer | Yes |
| Encoder / Connection of signal encoders / for resistance measurement with two-wire connection | Yes; Line resistances are also measured |
| Encoder / Connection of signal encoders / for resistance measurement with three-wire connection | Yes; Line resistances are also measured |
| Encoder / Connection of signal encoders / for resistance measurement with four-wire connection | Yes |
| Errors/accuracies / Temperature error (relative to input range), (+/-) | 0.02 %/K; ±0.02 %/K in impedance measuring range; ±0.007 % in all other measuring ranges |
| Errors/accuracies / Operational error limit in overall temperature range / Voltage, relative to input range, (+/-) | 1 %; ±1.0 % at ±1 V; ±0.6 % at ±10 V; ±0.7 % at 1 to 5 V |
| Errors/accuracies / Operational error limit in overall temperature range / Current, relative to input range, (+/-) | 1 %; at ±20 mA, 4 to 20 mA |
| Errors/accuracies / Operational error limit in overall temperature range / Resistance, relative to input range, (+/-) | 1.25 %; 0 to 500 ohms (4-conductor measurement, in range of 600 ohms) |
| Errors/accuracies / Basic error limit (operational limit at 25 °C) / Voltage, relative to input range, (+/-) | 0.7 %; 0.7% at ±1 V; 0.4% at ±10 V; 0.5% at 1 to 5 V |
| Errors/accuracies / Basic error limit (operational limit at 25 °C) / Current, relative to input range, (+/-) | 0.7 %; at ±20 mA, 4 to 20 mA |
| Errors/accuracies / Basic error limit (operational limit at 25 °C) / Resistance, relative to input range, (+/-) | 0.8 %; 0 to 500 ohms (4-conductor measurement, in range of 600 ohms) |
| Interrupts/diagnostics/status information / Diagnostics function | No |
| Potential separation / Potential separation analog inputs / Potential separation analog inputs | Yes; internal/external |
| Potential separation / Potential separation analog inputs / between the channels | No |
| Potential separation / Potential separation analog inputs / between the channels and backplane bus | Yes |
| Isolation / Isolation tested with | 2 120 V DC between bus and analog part; 500 V DC between bus and local ground; 2 120 V DC between analog part and local ground |
| Dimensions / Width | 25 mm |
| Dimensions / Height | 290 mm |
| Dimensions / Depth | 210 mm |
| Weights / Weight, approx. | 500 g |
Supported signals and ranges
- Supply voltage / Load voltage L+ / Rated value (DC): not necessary
- Analog inputs / For voltage/current measurement: 8
- Analog inputs / For resistance measurement: 4
- Analog inputs / permissible input voltage for voltage input (destruction limit),: 50 V
- Analog inputs / Constant measurement current for resistance-type transmitter,: 1.67 mA
- Analog inputs / Input ranges / Voltage: Yes
- Analog inputs / Input ranges / Current: Yes
- Analog inputs / Input ranges / Thermocouple: No
Scope of supply
We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.
Frequently asked questions
Is the same product family enough to identify a replacement?
The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.
What information is needed to check connections and accessories?
Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.
Can you assess a faulty part?
Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.
Why buy from FOXON
Replacement part availability
We will check current part availability and confirm the possible delivery date before you order.
New original and refurbished parts
We will specify the available version and condition of the particular unit in the quotation.
Parts with a warranty
We will confirm the warranty period according to the part condition and specific quotation.
Diagnostics and repairs
For a faulty unit, we will check the options for diagnostics and professional repair.
Part conditions available for sale
Part conditions and warranty
- New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
- New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
- New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
- New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
- Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
- Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
- Used (U): Functional used part. 3-month warranty.


Sales, repairs and buyback of automation parts
We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.
Need to buy or repair this part?
Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.
Request a quote for purchase or repairHighlighted items are mandatory.