SIMATIC S7-300, FM352-5 WITH SRC OUT, HIGH SPEED BOOLEAN PROCESSOR, FOR HIGH-SPEED LOGIC OPERATION 12 DI, 8 DO, 1 ENCODER INTERF. FOR RS422 INCR./SSI ENCODER More

Code: 6ES7352-5AH10-0AE0

Variant does not exist

Rezervace termínu

Get a quote
SIEMENS

SIMATIC S7-300, FM352-5 WITH SRC OUT, HIGH SPEED BOOLEAN PROCESSOR, FOR HIGH-SPEED LOGIC OPERATION 12 DI, 8 DO, 1 ENCODER INTERF. FOR RS422 INCR./SSI ENCODER More

Code: 6ES7352-5AH10-0AE0

Repair of the part

Name Code Delivery Warranty Price excl. VAT
Complete part repair 6ES7352-5AH10-0AE0 O 3-6 weeks 24 months On request Enquire a repair

6ES7352-5AH10-0AE0 – SIMATIC S7-300 module

Siemens SIMATIC S7-300 SIMATIC S7-300 module.

Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.

Request a quote for purchase or repair
YesSupply voltages / Rated value / DC 24 V
8; standard and up to 12 at 24 V DC encoder inputs as digital inputsDigital inputs / Number of digital inputs
600 m; shielded cable recommended if filtering set in 1.6 ms frame.Digital inputs / Cable length / Cable length, shielded, max.

Application and selection

Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.

Technical specifications

ManufacturerSiemens
Order number6ES7352-5AH10-0AE0
Product type designationSIMATIC S7-300 module
Supply voltages / Rated value / DC 24 VYes
Voltages and currents / Load voltage L+ / Rated value (DC)24 V
Voltages and currents / Load voltage L+ / reverse polarity protectionYes
Voltages and currents / Load voltage L+ / permissible range, lower limit (DC)20.4 V
Voltages and currents / Load voltage L+ / permissible range, upper limit (DC)28.8 V
Current consumption / from load voltage1L+, max.150 mA; typ. 60 mA
Current consumption / from load voltage 2L+ (without load), max.200 mA; typ. 60 mA, DI/DO supply
Current consumption / from load voltage 3L+ (with encoder), max.600 mA; typ. 80 mA plus encoder supply
Current consumption / from load voltage 3L+ (without encoder), max.200 mA; typ. 80 mA
Current consumption / from backplane bus DC 5 V, max.1100 mA; typically
Current consumption / Power loss, typ.6.5 W
Memory / Memory Card, RAM128 KByte; required for operation, MMC
Interfaces / Updating timePLC interface: 5ms (2.6 ms typ)
Connection point / required front connectors1 x 40-pin
CPU/programming / Program cycle time (scan)1 µs
Digital inputs / Number of digital inputs8; standard and up to 12 at 24 V DC encoder inputs as digital inputs
Digital inputs / Cable length / Cable length, shielded, max.600 m; shielded cable recommended if filtering set in 1.6 ms frame.
Digital inputs / Cable length / Cable length unshielded, max.100 m
Digital inputs / Input voltage / Rated value, DC24 V
Digital inputs / Input voltage / for signal "0"30 V to 5 V
Digital inputs / Input voltage / for signal "1"11 to 30 V
Digital inputs / Input current / for signal "0", max. (permissible quiescent current)1.5 mA
Digital inputs / Input current / for signal "1", typ.3.8 mA
Input delay (for rated value of input voltage) / Input frequency (with 0.1 ms delay), max.200 kHz
Input delay (for rated value of input voltage) / Programmable digital filter delayNone, 5µs, 10µs, 15µs, 20µs, 50µs, 1.5ms
Input delay (for rated value of input voltage) / Minimum pulse width for program reactions1µs, 5µs, 10µs, 15µs, 20µs, 50µs, 1.6ms
Input delay (for rated value of input voltage) / for standard inputs / at "0" to "1", max.3 µs; typ. 1.5 µs
Digital outputs / Number of digital outputs8
Digital outputs / P-switchingYes
Digital outputs / Cable length, shielded, max.600 m
Digital outputs / Cable length unshielded, max.100 m
Digital outputs / Short-circuit protection of the outputYes; Overvoltage protection, thermal protection
Digital outputs / Response threshold, typ.1.7 A to 3.5 A
Digital outputs / Limitation of inductive shutdown voltage to2M +45 V typ, (40 to 55 V) Note: no protection against inductive kickback >55mJ
Digital outputs / Lamp load, max.5 W
Digital outputs / Controlling a digital inputNo
Digital outputs / Output voltage / Rated value (DC)24 V
Digital outputs / Output voltage / for signal "0" (DC), max.28.8 V
Digital outputs / Output voltage / for signal "1" (DC), max.0.5 V
Digital outputs / Output current / for signal "1" rated value0.5 A; at 60 °C
Digital outputs / Output current / for signal "1" permissible range for 0 to 60 °C, min.5 mA
Digital outputs / Output current / for signal "1" permissible range for 0 to 60 °C, max.600 mA
Digital outputs / Output current / for signal "0" residual current, max.1 mA
Digital outputs / Output delay with resistive load / "0" to "1", max.1 µs; 0.6 µs 50 mA / 1.0 µs 0.5 Amp
Digital outputs / Output delay with resistive load / "1" to "0", max.1.5 µs; 1.7µs 50 mA / 1.5µs 0.5 Amp
Digital outputs / Parallel switching of 2 outputs / for increased powerYes; 2
Switching frequency / with resistive load, max.100 kHz; 20 kHz at 0.5 A; 100 kHz at 0.25 A
Switching frequency / with inductive load, max.2 Hz; 2 Hz at 0.5 A with external commutator diodes; 0.5 Hz at 0.5 A without external commutator diodes
Switching frequency / on lamp load, max.10 Hz
Encoder supply / 5 V encoder supply / 5 VYes
Encoder supply / 5 V encoder supply / Short-circuit protectionYes; Electronic overload. No protection on applying a normal or counter voltage.
Encoder supply / 5 V encoder supply / Output current, max.250 mA
Encoder supply / 24 V encoder supply / 24 VYes
Encoder supply / 24 V encoder supply / Short-circuit protectionYes; Overvoltage and overheating protection if overloaded. Diagnostics if output reaches temperature limit. No protection when setting up a normal or counter voltage
Encoder supply / 24 V encoder supply / Output current, max.400 mA
Encoder / Connectable encoders / Incremental encoder (symmetrical)Yes
Encoder / Connectable encoders / Incremental encoder (asymmetrical)Yes
Encoder / Connectable encoders / Absolute encoder (SSI)Yes
Encoder / Connectable encoders / 2-wire BEROSYes; typ. 1 A
Encoder / Connectable encoders / permissible quiescent current (2-wire BEROS), max.1.5 mA
Encoder / Encoder signals, incremental encoder (symmetrical) / Trace mark signalsA, notA, B, notB
Encoder / Encoder signals, incremental encoder (symmetrical) / Zero mark signalN, notN
Encoder / Encoder signals, incremental encoder (symmetrical) / Input frequency, max.1 MHz
Encoder signals, incremental encoder (symmetrical) (continued) / Cable length, shielded, max.100 m; Cable length, RS-422 (5V) incremental encoder, Siemens type 6FX201-2, 5V supply: 500kHz, 32 m, shielded, max.; Cable length, RS 422 (5V) incremental encoder, Siemens type 6FX201-2, 24V supply: 500 kHz, 100 m, shielded, max.
Encoder signals, incremental encoder (asymmetrical) / Trace mark signalsA, B
Encoder signals, incremental encoder (asymmetrical) / Zero mark signalN
Encoder signals, incremental encoder (asymmetrical) / Input voltage24 V
Encoder signals, incremental encoder (asymmetrical) / Input frequency, max.200 kHz
Encoder signals, incremental encoder (asymmetrical) / cable length, shielded, max.50 m; Cable length, HTL incremental encoder, Siemens, type 6FX2001-4: 50kHz, 25 m shielded, max., 25kHz, 50 m shielded, max.
Encoder signals, absolute encoder (SSI) / Data signalDATA, notDATA
Encoder signals, absolute encoder (SSI) / Clock signalCK, notCK
Encoder signals, absolute encoder (SSI) / Telegram length13 or 25 bit
Encoder signals, absolute encoder (SSI) / Clock frequency, max.1 MHz; 125 kHz, 250 kHz, 500 kHz, or 1 MHz
Encoder signals, absolute encoder (SSI) / Cable length, shielded, max.320 m; Cable length, RS-422 SSI absolute encoder, Siemens Type 6FX201-5, 24V supply: 125 kHz, 320 m, shielded, max.; 250kHz, 160 meter shielded, max., 500kHz, 60 m shielded, max., 1MHz, 20 m shielded, max.
Encoder signals, absolute encoder (SSI) / Monoflop timeadjustable: 16/32/48/64 µs
Encoder signals, absolute encoder (SSI) / Listening modeYes; one or two stations
Encoder signals, absolute encoder (SSI) / MultiturnYes; 25 bit message frame
Encoder signal evaluation / Counting direction, forwardYes
Encoder signal evaluation / Counting direction, backwardYes
Reaction times / Input and output reaction timet5V input to 24V output, 0-filter: 1 to 4µs (typ.); 24V input to 24V output, 0-filter: 2 to 6µs (typ.)
Counters / Counting range, DescriptionCounter range (16-bit counter): - 32768 to 32767 (user-specific within this range); counter range (32-bit counter): - 2,147,483,648 to 2,147,483,647 (user-specific within this range)
Counters / Counting range, lower limit2147483648
Counters / Counting range, upper limit2,147,483,647
Counters / Counting mode / Counting mode, individualYes
Counters / Counting mode / Counting mode, continuousYes
Counters / Counting mode / Counting mode, periodicYes
Status information/ alarms/diagnostics / Alarms / Process alarmYes; 8 available; for generation by user program
Status information/ alarms/diagnostics / Diagnoses / Wire break in signal encoder cableYes
Status information/ alarms/diagnostics / Diagnoses / Overflow/underflowYes
Status information/ alarms/diagnostics / Diagnoses / missing load voltageYes
Isolation / between 1L and 2L and 3LYes; 75 V DC / 60 V AC
Isolation / between digital I/O & 2L and encoder I/O & 3LYes (75 V DC, 60 V AC)
Isolation / between backplane bus and digital & encoder I/O & 1L & 2L & 3LYes (75 V DC, 60 V AC)
Isolation / Galvanic isolation, digital inputs / galvanic isolation, digital inputsYes
Dimensions and weight / Width80 mm
Dimensions and weight / Height125 mm
Dimensions and weight / Depth120 mm
Weights / Weight, approx.434 g

Connections and conditions of use

  • Interfaces / Updating time: PLC interface: 5ms (2.6 ms typ)
  • Connection point / required front connectors: 1 x 40-pin
  • Digital inputs / Input voltage / for signal "0": 30 V to 5 V
  • Digital inputs / Input voltage / for signal "1": 11 to 30 V
  • Digital inputs / Input current / for signal "0", max. (permissible quiescent current): 1.5 mA
  • Digital inputs / Input current / for signal "1", typ.: 3.8 mA
  • Digital outputs / Output voltage / for signal "0" (DC), max.: 28.8 V
  • Digital outputs / Output voltage / for signal "1" (DC), max.: 0.5 V

Scope of supply

We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.

Frequently asked questions

Is the same product family enough to identify a replacement?

The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.

What information is needed to check connections and accessories?

Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.

Can you assess a faulty part?

Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.

Why buy from FOXON

1

Replacement part availability

We will check current part availability and confirm the possible delivery date before you order.

2

New original and refurbished parts

We will specify the available version and condition of the particular unit in the quotation.

3

Parts with a warranty

We will confirm the warranty period according to the part condition and specific quotation.

4

Diagnostics and repairs

For a faulty unit, we will check the options for diagnostics and professional repair.

More than 3,500customers
We deliver tomore than 100 countries
Express delivery?We will check. Contact us now.

Part conditions available for sale

Part conditions and warranty
  • New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
  • New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
  • New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
  • New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
  • Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
  • Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
  • Used (U): Functional used part. 3-month warranty.

Sales, repairs and buyback of automation parts

We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.

More about parts sales, repairs and buyback

Need to buy or repair this part?

Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.

Request a quote for purchase or repair