6ES7350-1AH03-0AE0

6ES7350-1AH03-0AE0

Sales, Repair, Purchase

SIEMENS

SIMATIC S7-300, Counter module FM 350-1 for S7-300, Counter functions up to 500 kHz 1 channel for connection of 5 V and 24 V incremental encoders Isochronous mode; Measuring range types incl. configuration package on CD More

Code: 6ES7350-1AH03-0AE0

from 421 EUR excl. VAT (509,41 EUR Incl. VAT)
Total in stock: 13 pcs External stock 13 pcs
Variant does not exist

Rezervace termínu

Get a quote
SIEMENS

SIMATIC S7-300, Counter module FM 350-1 for S7-300, Counter functions up to 500 kHz 1 channel for connection of 5 V and 24 V incremental encoders Isochronous mode; Measuring range types incl. configuration package on CD More

Code: 6ES7350-1AH03-0AE0

Part Sales 2

Condition Code Warranty Availability Delivery
Express?
Price excl. VAT
New in sealed box (NC) 6ES7350-1AH03-0AE0 NC 12/24 months In external stock 2 pcs
Within 2-4 days / Express
On request
Refurbished (R) 6ES7350-1AH03-0AE0 R 12/24 months In external stock 11 pcs
Within 2-4 days / Express
On request

Repair of the part

Name Code Delivery Warranty Price excl. VAT
Complete part repair 6ES7350-1AH03-0AE0 O 3-6 weeks 24 months On request Enquire a repair

6ES7350-1AH03-0AE0 – FM 350-1

SIMATIC S7-300, counter module FM 350-1 for S7-300, counter functions up to 500 kHz 1 channel for connection of 5 V and 24 V incremental encoders isochronous mode; measuring range types incl. configuration package on CD

Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.

Request a quote for purchase or repair
24 VSupply voltage / Auxiliary voltage 1L+, load voltage 2L+ / Rated value (DC)
20.4 V; Dynamic 18.5 VSupply voltage / Auxiliary voltage 1L+, load voltage 2L+ / permissible range, lower limit (DC)
28.8 V; dynamic 30.2 VSupply voltage / Auxiliary voltage 1L+, load voltage 2L+ / permissible range, upper limit (DC)

Application and selection

Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.

Technical specifications

ManufacturerSiemens
Order number6ES7350-1AH03-0AE0
Supply voltage / Auxiliary voltage 1L+, load voltage 2L+ / Rated value (DC)24 V
Supply voltage / Auxiliary voltage 1L+, load voltage 2L+ / permissible range, lower limit (DC)20.4 V; Dynamic 18.5 V
Supply voltage / Auxiliary voltage 1L+, load voltage 2L+ / permissible range, upper limit (DC)28.8 V; dynamic 30.2 V
Input current / from load voltage 1L+ (without load), max.40 mA
Input current / from backplane bus 5 V DC, max.160 mA
Encoder supply / 5 V encoder supply / 5 VYes; 5.2 V ±2 %
Encoder supply / 5 V encoder supply / Output current, max.300 mA
Encoder supply / 24 V encoder supply / 24 VYes; 1L+ (-3 V)
Encoder supply / 24 V encoder supply / Output current, max.400 mA
Power loss / Power loss, typ.4.5 W
Digital inputs / Number of digital inputs3
Digital inputs / Functions1 for gate start, 1 for gate stop, 1 for setting the counter
Digital inputs / Input voltage / for signal "0"-28.8 ... +5V
Digital inputs / Input voltage / for signal "1"+11 to +28.8V
Digital inputs / Input current / for signal "1", typ.9 mA
Digital outputs / Number of digital outputs2
Digital outputs / Short-circuit protectionYes; Clocked electronically
Digital outputs / Limitation of inductive shutdown voltage to2L+ (-39 V)
Digital outputs / Output voltage / for signal "0", max.3 V
Digital outputs / Output voltage / for signal "1", min.2L+ (-1,5 V)
Digital outputs / Output current / for signal "1" rated value0.5 A
Digital outputs / Output current / for signal "1" permissible range for 0 to 60 °C, min.5 mA
Digital outputs / Output current / for signal "1" permissible range for 0 to 60 °C, max.0.6 A
Digital outputs / Output delay with resistive load / "0" to "1", max.300 µs
Encoder / Connectable encoders / Incremental encoder (symmetrical)Yes; With 2 pulse trains offset by 90°
Encoder / Connectable encoders / Incremental encoder (asymmetrical)Yes
Encoder / Connectable encoders / 24 V initiatorYes
Encoder / Connectable encoders / 24 V directional elementYes; 1 pulse train, 1 direction level
Counter / Number of counter inputs1; 32 bit or ±31 bit
Counter / Counter input 5 V / TypeRS 422
Counter / Counter input 5 V / terminating resistor220 Ω
Counter / Counter input 5 V / Differential input voltage1,3 V
Counter / Counter input 5 V / Counting frequency, max.500 kHz
Counter / Counter input 24 V / Input voltage for signal "0"-28.8 ... +5V
Counter / Counter input 24 V / Input voltage for signal "1"+11 to +28.8V
Counter / Counter input 24 V / Input current for signal "1", typ.9 mA
Counter / Counter input 24 V / Counting frequency, max.200 kHz
Counter / Counter input 24 V / Minimum pulse width2.5 µs
Potential separation / Potential separation digital inputs / between the channels and backplane busYes; Optocoupler
Potential separation / Potential separation digital outputs / between the channels and backplane busYes; Optocoupler
Potential separation / Potential separation counter / between the channels and backplane busYes; Optocoupler
Isolation / Isolation tested with500 V
Connection method / required front connector1x 20-pin
Dimensions / Width40 mm
Dimensions / Height125 mm
Dimensions / Depth120 mm
Weights / Weight, approx.250 g
Product type designationFM 350-1

Connections and conditions of use

  • Digital inputs / Input voltage / for signal "0": -28.8 ... +5V
  • Digital inputs / Input voltage / for signal "1": +11 to +28.8V
  • Digital inputs / Input current / for signal "1", typ.: 9 mA
  • Digital outputs / Output voltage / for signal "0", max.: 3 V
  • Digital outputs / Output voltage / for signal "1", min.: 2L+ (-1,5 V)
  • Digital outputs / Output current / for signal "1" rated value: 0.5 A
  • Digital outputs / Output current / for signal "1" permissible range for 0 to 60 °C, min.: 5 mA
  • Digital outputs / Output current / for signal "1" permissible range for 0 to 60 °C, max.: 0.6 A

Scope of supply

We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.

Frequently asked questions

Is the same product family enough to identify a replacement?

The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.

What information is needed to check connections and accessories?

Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.

Can you assess a faulty part?

Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.

Why buy from FOXON

1

Replacement part availability

We will check current part availability and confirm the possible delivery date before you order.

2

New original and refurbished parts

We will specify the available version and condition of the particular unit in the quotation.

3

Parts with a warranty

We will confirm the warranty period according to the part condition and specific quotation.

4

Diagnostics and repairs

For a faulty unit, we will check the options for diagnostics and professional repair.

More than 3,500customers
We deliver tomore than 100 countries
Express delivery?We will check. Contact us now.

Part conditions available for sale

Part conditions and warranty
  • New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
  • New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
  • New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
  • New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
  • Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
  • Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
  • Used (U): Functional used part. 3-month warranty.

Sales, repairs and buyback of automation parts

We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.

More about parts sales, repairs and buyback

Need to buy or repair this part?

Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.

Request a quote for purchase or repair