from 467,06 EUR Incl. VAT
6ES7350-1AH03-0AE0
- SIEMENS
- SIMATIC S7-300
- Function Modules
- 6ES7350-1AH03-0AE0
6ES7350-1AH03-0AE0
SIMATIC S7-300, Counter module FM 350-1 for S7-300, Counter functions up to 500 kHz 1 channel for connection of 5 V and 24 V incremental encoders Isochronous mode; Measuring range types incl. configuration package on CD More
Code: 6ES7350-1AH03-0AE0
SIMATIC S7-300, Counter module FM 350-1 for S7-300, Counter functions up to 500 kHz 1 channel for connection of 5 V and 24 V incremental encoders Isochronous mode; Measuring range types incl. configuration package on CD More
Code: 6ES7350-1AH03-0AE0
Part Sales 2
| Condition | Code | Warranty | Availability |
Delivery Express? | Price excl. VAT | |
|---|---|---|---|---|---|---|
| New in sealed box (NC) | 6ES7350-1AH03-0AE0 NC | 12/24 months | In external stock 2 pcs |
Within 2-4 days / Express
|
On request
|
|
| Refurbished (R) | 6ES7350-1AH03-0AE0 R | 12/24 months | In external stock 11 pcs |
Within 2-4 days / Express
|
On request
|
Repair of the part
| Name | Code | Delivery | Warranty | Price excl. VAT | |
|---|---|---|---|---|---|
| Complete part repair | 6ES7350-1AH03-0AE0 O | 3-6 weeks | 24 months | On request | Enquire a repair |
6ES7350-1AH03-0AE0 – FM 350-1
SIMATIC S7-300, counter module FM 350-1 for S7-300, counter functions up to 500 kHz 1 channel for connection of 5 V and 24 V incremental encoders isochronous mode; measuring range types incl. configuration package on CD
Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.
Application and selection
Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.
Technical specifications
| Manufacturer | Siemens |
|---|---|
| Order number | 6ES7350-1AH03-0AE0 |
| Supply voltage / Auxiliary voltage 1L+, load voltage 2L+ / Rated value (DC) | 24 V |
| Supply voltage / Auxiliary voltage 1L+, load voltage 2L+ / permissible range, lower limit (DC) | 20.4 V; Dynamic 18.5 V |
| Supply voltage / Auxiliary voltage 1L+, load voltage 2L+ / permissible range, upper limit (DC) | 28.8 V; dynamic 30.2 V |
| Input current / from load voltage 1L+ (without load), max. | 40 mA |
| Input current / from backplane bus 5 V DC, max. | 160 mA |
| Encoder supply / 5 V encoder supply / 5 V | Yes; 5.2 V ±2 % |
| Encoder supply / 5 V encoder supply / Output current, max. | 300 mA |
| Encoder supply / 24 V encoder supply / 24 V | Yes; 1L+ (-3 V) |
| Encoder supply / 24 V encoder supply / Output current, max. | 400 mA |
| Power loss / Power loss, typ. | 4.5 W |
| Digital inputs / Number of digital inputs | 3 |
| Digital inputs / Functions | 1 for gate start, 1 for gate stop, 1 for setting the counter |
| Digital inputs / Input voltage / for signal "0" | -28.8 ... +5V |
| Digital inputs / Input voltage / for signal "1" | +11 to +28.8V |
| Digital inputs / Input current / for signal "1", typ. | 9 mA |
| Digital outputs / Number of digital outputs | 2 |
| Digital outputs / Short-circuit protection | Yes; Clocked electronically |
| Digital outputs / Limitation of inductive shutdown voltage to | 2L+ (-39 V) |
| Digital outputs / Output voltage / for signal "0", max. | 3 V |
| Digital outputs / Output voltage / for signal "1", min. | 2L+ (-1,5 V) |
| Digital outputs / Output current / for signal "1" rated value | 0.5 A |
| Digital outputs / Output current / for signal "1" permissible range for 0 to 60 °C, min. | 5 mA |
| Digital outputs / Output current / for signal "1" permissible range for 0 to 60 °C, max. | 0.6 A |
| Digital outputs / Output delay with resistive load / "0" to "1", max. | 300 µs |
| Encoder / Connectable encoders / Incremental encoder (symmetrical) | Yes; With 2 pulse trains offset by 90° |
| Encoder / Connectable encoders / Incremental encoder (asymmetrical) | Yes |
| Encoder / Connectable encoders / 24 V initiator | Yes |
| Encoder / Connectable encoders / 24 V directional element | Yes; 1 pulse train, 1 direction level |
| Counter / Number of counter inputs | 1; 32 bit or ±31 bit |
| Counter / Counter input 5 V / Type | RS 422 |
| Counter / Counter input 5 V / terminating resistor | 220 Ω |
| Counter / Counter input 5 V / Differential input voltage | 1,3 V |
| Counter / Counter input 5 V / Counting frequency, max. | 500 kHz |
| Counter / Counter input 24 V / Input voltage for signal "0" | -28.8 ... +5V |
| Counter / Counter input 24 V / Input voltage for signal "1" | +11 to +28.8V |
| Counter / Counter input 24 V / Input current for signal "1", typ. | 9 mA |
| Counter / Counter input 24 V / Counting frequency, max. | 200 kHz |
| Counter / Counter input 24 V / Minimum pulse width | 2.5 µs |
| Potential separation / Potential separation digital inputs / between the channels and backplane bus | Yes; Optocoupler |
| Potential separation / Potential separation digital outputs / between the channels and backplane bus | Yes; Optocoupler |
| Potential separation / Potential separation counter / between the channels and backplane bus | Yes; Optocoupler |
| Isolation / Isolation tested with | 500 V |
| Connection method / required front connector | 1x 20-pin |
| Dimensions / Width | 40 mm |
| Dimensions / Height | 125 mm |
| Dimensions / Depth | 120 mm |
| Weights / Weight, approx. | 250 g |
| Product type designation | FM 350-1 |
Connections and conditions of use
- Digital inputs / Input voltage / for signal "0": -28.8 ... +5V
- Digital inputs / Input voltage / for signal "1": +11 to +28.8V
- Digital inputs / Input current / for signal "1", typ.: 9 mA
- Digital outputs / Output voltage / for signal "0", max.: 3 V
- Digital outputs / Output voltage / for signal "1", min.: 2L+ (-1,5 V)
- Digital outputs / Output current / for signal "1" rated value: 0.5 A
- Digital outputs / Output current / for signal "1" permissible range for 0 to 60 °C, min.: 5 mA
- Digital outputs / Output current / for signal "1" permissible range for 0 to 60 °C, max.: 0.6 A
Scope of supply
We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.
Frequently asked questions
Is the same product family enough to identify a replacement?
The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.
What information is needed to check connections and accessories?
Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.
Can you assess a faulty part?
Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.
Why buy from FOXON
Replacement part availability
We will check current part availability and confirm the possible delivery date before you order.
New original and refurbished parts
We will specify the available version and condition of the particular unit in the quotation.
Parts with a warranty
We will confirm the warranty period according to the part condition and specific quotation.
Diagnostics and repairs
For a faulty unit, we will check the options for diagnostics and professional repair.
Part conditions available for sale
Part conditions and warranty
- New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
- New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
- New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
- New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
- Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
- Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
- Used (U): Functional used part. 3-month warranty.


Sales, repairs and buyback of automation parts
We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.
Need to buy or repair this part?
Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.
Request a quote for purchase or repairHighlighted items are mandatory.