from 341,22 EUR Incl. VAT
6ES7334-0KE00-0AB0
- SIEMENS
- SIMATIC S7-300
- Analog Inputs / Outputs
- 6ES7334-0KE00-0AB0
6ES7334-0KE00-0AB0
SIMATIC S7-300, Analog module SM 334, isolated, 4 AI/2 AO, 12 bit, 0-10 V f. Pt100 (climatic range -120-155 degrees) and 10 kOhm measuring range, 1x 20-pole More
Code: 6ES7334-0KE00-0AB0
SIMATIC S7-300, Analog module SM 334, isolated, 4 AI/2 AO, 12 bit, 0-10 V f. Pt100 (climatic range -120-155 degrees) and 10 kOhm measuring range, 1x 20-pole More
Code: 6ES7334-0KE00-0AB0
Part Sales 3
| Condition | Code | Warranty | Availability |
Delivery Express? | Price excl. VAT | |
|---|---|---|---|---|---|---|
| New in sealed box (NC) | 6ES7334-0KE00-0AB0 NC | 12/24 months | In external stock 5 pcs |
Within 2-4 days / Express
|
On request
|
|
| New without box (NW) | 6ES7334-0KE00-0AB0 NW | 12/24 months | In stock FOXON 1 pcs |
282 EUR
|
||
| Refurbished (R) | 6ES7334-0KE00-0AB0 R | 12/24 months | In external stock 10 pcs |
Within 2-4 days / Express
|
On request
|
Repair of the part
| Name | Code | Delivery | Warranty | Price excl. VAT | |
|---|---|---|---|---|---|
| Complete part repair | 6ES7334-0KE00-0AB0 O | 3-6 weeks | 24 months | On request | Enquire a repair |
6ES7334-0KE00-0AB0 – SM 334
SIMATIC S7-300, analog module SM 334, isolated, 4 AI/2 AO, 12 bit, 0-10 V for Pt100 (climatic range -120-155 degrees) and 10 kOhm measuring range, 1x 20-pole
Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.
Application and selection
Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.
Technical specifications
| Manufacturer | Siemens |
|---|---|
| Order number | 6ES7334-0KE00-0AB0 |
| Supply voltage / Load voltage L+ / Rated value (DC) | 24 V |
| Supply voltage / Load voltage L+ / Reverse polarity protection | Yes |
| Input current / from supply and load voltage L+ (without load), max. | 80 mA |
| Input current / from backplane bus 5 V DC, max. | 60 mA |
| Power loss / Power loss, typ. | 2 W |
| Analog inputs / Number of analog inputs | 4 |
| Analog inputs / For voltage measurement | 2 |
| Analog inputs / For resistance measurement | 4 |
| Analog inputs / permissible input voltage for voltage input (destruction limit), | 20 V; continuous; 75 V for max. 1 s (mark to space ratio 1:20) |
| Analog inputs / Constant measurement current for resistance-type transmitter, | 490 µA; at PT100 (490 µA), at 10 kOhm (105 µa) |
| Analog inputs / Cycle time (all channels) max. | 85 ms |
| Analog inputs / Input ranges / Voltage | Yes |
| Analog inputs / Input ranges / Current | No |
| Analog inputs / Input ranges / Thermocouple | No |
| Analog inputs / Input ranges / Resistance thermometer | Yes |
| Analog inputs / Input ranges / Resistance | Yes |
| Analog inputs / Input ranges (rated values), voltages / 0 to +10 V | Yes |
| Analog inputs / Input ranges (rated values), voltages / Input resistance (0 to 10 V) | 100 kΩ |
| Analog inputs / Input ranges (rated values), resistance thermometer / Pt 100 | Yes; only climatic range |
| Analog inputs / Input ranges (rated values), resistors / 0 to 10000 ohms | Yes |
| Analog inputs / Characteristic linearization / Parameterizable | Yes |
| Analog inputs / Characteristic linearization / for resistance thermometer | Pt100 (climate) |
| Analog inputs / Cable length / shielded, max. | 100 m |
| Analog outputs / Number of analog outputs | 2 |
| Analog outputs / Voltage output, short-circuit protection | Yes |
| Analog outputs / Voltage output, short-circuit current, max. | 30 mA |
| Analog outputs / Output ranges, voltage / 0 to 10 V | Yes |
| Analog outputs / Load impedance (in rated range of output) / with voltage outputs, min. | 2.5 kΩ |
| Analog outputs / Load impedance (in rated range of output) / with voltage outputs, capacitive load, max. | 1 µF |
| Analog outputs / Cable length / shielded, max. | 100 m |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max. | 12 bit |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Integration time, parameterizable | Yes |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Integration time (ms) | 16,67 / 20 ms |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Interference voltage suppression for interference | 50 / 60 Hz |
| Analog value generation for the outputs / Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max. | 12 bit |
| Analog value generation for the outputs / Integration and conversion time/resolution per channel / Conversion time (per channel) | 500 µs |
| Analog value generation for the outputs / Settling time / for resistive load | 0.8 ms |
| Analog value generation for the outputs / Settling time / for capacitive load | 0.8 ms |
| Encoder / Connection of signal encoders / for voltage measurement | Yes |
| Encoder / Connection of signal encoders / for resistance measurement with two-wire connection | Yes |
| Encoder / Connection of signal encoders / for resistance measurement with three-wire connection | Yes |
| Encoder / Connection of signal encoders / for resistance measurement with four-wire connection | Yes |
| Errors/accuracies / Operational error limit in overall temperature range / Voltage, relative to input range, (+/-) | 0.7 %; 0 to 10V |
| Errors/accuracies / Operational error limit in overall temperature range / Resistance, relative to input range, (+/-) | 3.5 %; 10 kOhm |
| Errors/accuracies / Operational error limit in overall temperature range / Resistance thermometer, relative to input range, (+/-) | 1 % |
| Errors/accuracies / Operational error limit in overall temperature range / Voltage, relative to output range, (+/-) | 1 % |
| Errors/accuracies / Basic error limit (operational limit at 25 °C) / Voltage, relative to input range, (+/-) | 0.5 %; 0 to 10V |
| Errors/accuracies / Basic error limit (operational limit at 25 °C) / Resistance, relative to input range, (+/-) | 2.8 %; 10 kOhm |
| Errors/accuracies / Basic error limit (operational limit at 25 °C) / Resistance thermometer, relative to input range, (+/-) | 0.8 % |
| Errors/accuracies / Basic error limit (operational limit at 25 °C) / Voltage, relative to output range, (+/-) | 0.85 % |
| Interrupts/diagnostics/status information / Alarms | No |
| Interrupts/diagnostics/status information / Diagnostics function | No |
| Potential separation / Potential separation analog inputs / between the channels and backplane bus | Yes |
| Potential separation / Potential separation analog outputs / between the channels | No |
| Potential separation / Potential separation analog outputs / between the channels and backplane bus | Yes |
| Potential separation / Potential separation analog outputs / between the channels and the power supply of the | Yes |
| Isolation / Isolation tested with | 500 V DC |
| Connection method / required front connector | 20-pin |
| Dimensions / Width | 40 mm |
| Dimensions / Height | 125 mm |
| Dimensions / Depth | 117 mm |
| Weights / Weight, approx. | 200 g |
| Product type designation | SM 334 |
| Number of poles | 20 |
Connections and conditions of use
- Encoder / Connection of signal encoders / for voltage measurement: Yes
- Encoder / Connection of signal encoders / for resistance measurement with two-wire connection: Yes
- Encoder / Connection of signal encoders / for resistance measurement with three-wire connection: Yes
- Encoder / Connection of signal encoders / for resistance measurement with four-wire connection: Yes
- Connection method / required front connector: 20-pin
Scope of supply
We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.
Frequently asked questions
Is the same product family enough to identify a replacement?
The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.
What information is needed to check connections and accessories?
Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.
Can you assess a faulty part?
Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.
Why buy from FOXON
Replacement part availability
We will check current part availability and confirm the possible delivery date before you order.
New original and refurbished parts
We will specify the available version and condition of the particular unit in the quotation.
Parts with a warranty
We will confirm the warranty period according to the part condition and specific quotation.
Diagnostics and repairs
For a faulty unit, we will check the options for diagnostics and professional repair.
Part conditions available for sale
Part conditions and warranty
- New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
- New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
- New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
- New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
- Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
- Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
- Used (U): Functional used part. 3-month warranty.


Sales, repairs and buyback of automation parts
We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.
Need to buy or repair this part?
Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.
Request a quote for purchase or repairHighlighted items are mandatory.






