from 47,19 EUR Incl. VAT
6ES7334-0CE01-0AA0
- SIEMENS
- SIMATIC S7-300
- Analog Inputs / Outputs
- 6ES7334-0CE01-0AA0
6ES7334-0CE01-0AA0
SIMATIC S7-300, Analog module SM 334, Non-isolated 4 AI/2 AO, 1x 20-pole, Removing and inserting possible with active backplane bus More
Code: 6ES7334-0CE01-0AA0
SIMATIC S7-300, Analog module SM 334, Non-isolated 4 AI/2 AO, 1x 20-pole, Removing and inserting possible with active backplane bus More
Code: 6ES7334-0CE01-0AA0
Part Sales 3
| Condition | Code | Warranty | Availability |
Delivery Express? | Price excl. VAT | |
|---|---|---|---|---|---|---|
| New in sealed box (NC) | 6ES7334-0CE01-0AA0 NC | 12/24 months | In external stock 8 pcs |
Within 2-4 days / Express
|
On request
|
|
| Refurbished (R) | 6ES7334-0CE01-0AA0 R | 12/24 months | In external stock 13 pcs |
Within 2-4 days / Express
|
On request
|
|
| Used (U) | 6ES7334-0CE01-0AA0 U | 3 months | In external stock 1 pcs |
Within 2-4 days / Express
|
On request
|
Repair of the part
| Name | Code | Delivery | Warranty | Price excl. VAT | |
|---|---|---|---|---|---|
| Complete part repair | 6ES7334-0CE01-0AA0 O | 3-6 weeks | 24 months | On request | Enquire a repair |
6ES7334-0CE01-0AA0 – SM 334
SIMATIC S7-300, analog module SM 334, non-isolated 4 AI/2 AO, 1x 20-pole, removing and inserting with active backplane bus possible
Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.
Application and selection
Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.
Technical specifications
| Manufacturer | Siemens |
|---|---|
| Order number | 6ES7334-0CE01-0AA0 |
| Supply voltage / Load voltage L+ / Rated value (DC) | 24 V |
| Input current / from supply and load voltage L+ (without load), max. | 110 mA |
| Input current / from backplane bus 5 V DC, max. | 55 mA |
| Power loss / Power loss, typ. | 3 W |
| Analog inputs / Number of analog inputs | 4 |
| Analog inputs / For voltage measurement | 4 |
| Analog inputs / permissible input voltage for voltage input (destruction limit), | 20 V |
| Analog inputs / permissible input current for current input (destruction limit), | 40 mA |
| Analog inputs / Cycle time (all channels) max. | 5 ms |
| Analog inputs / Input ranges / Voltage | Yes |
| Analog inputs / Input ranges / Current | Yes |
| Analog inputs / Input ranges / Thermocouple | No |
| Analog inputs / Input ranges / Resistance thermometer | No |
| Analog inputs / Input ranges / Resistance | No |
| Analog inputs / Input ranges (rated values), voltages / 0 to +10 V | Yes |
| Analog inputs / Input ranges (rated values), voltages / Input resistance (0 to 10 V) | 100 kΩ |
| Analog inputs / Input ranges (rated values), currents / 0 to 20 mA | Yes |
| Analog inputs / Input ranges (rated values), currents / Input resistance (0 to 20 mA) | 50 Ω |
| Analog inputs / Cable length / shielded, max. | 200 m |
| Analog outputs / Number of analog outputs | 2 |
| Analog outputs / Voltage output, short-circuit protection | Yes |
| Analog outputs / Voltage output, short-circuit current, max. | 11 mA |
| Analog outputs / Current output, no-load voltage, max. | 15 V |
| Analog outputs / Output ranges, voltage / 0 to 10 V | Yes |
| Analog outputs / Output ranges, current / 0 to 20 mA | Yes |
| Analog outputs / Load impedance (in rated range of output) / with voltage outputs, min. | 5 kΩ |
| Analog outputs / Load impedance (in rated range of output) / with voltage outputs, capacitive load, max. | 1 µF |
| Analog outputs / Load impedance (in rated range of output) / with current outputs, max. | 300 Ω |
| Analog outputs / Load impedance (in rated range of output) / with current outputs, inductive load, max. | 1 mH |
| Analog outputs / Cable length / shielded, max. | 200 m |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max. | 8 bit |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Integration time, parameterizable | No |
| Analog value generation for the outputs / Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max. | 8 bit |
| Analog value generation for the outputs / Integration and conversion time/resolution per channel / Conversion time (per channel) | 500 µs |
| Analog value generation for the outputs / Settling time / for resistive load | 0.3 ms |
| Analog value generation for the outputs / Settling time / for capacitive load | 3 ms |
| Analog value generation for the outputs / Settling time / for inductive load | 0.3 ms |
| Encoder / Connection of signal encoders / for voltage measurement | Yes |
| Encoder / Connection of signal encoders / for current measurement as 2-wire transducer | No |
| Encoder / Connection of signal encoders / for current measurement as 4-wire transducer | Yes |
| Errors/accuracies / Operational error limit in overall temperature range / Voltage, relative to input range, (+/-) | 0.9 % |
| Errors/accuracies / Operational error limit in overall temperature range / Current, relative to input range, (+/-) | 0.8 % |
| Errors/accuracies / Operational error limit in overall temperature range / Voltage, relative to output range, (+/-) | 0.6 % |
| Errors/accuracies / Operational error limit in overall temperature range / Current, relative to output range, (+/-) | 1 % |
| Errors/accuracies / Basic error limit (operational limit at 25 °C) / Voltage, relative to input range, (+/-) | 0.7 % |
| Errors/accuracies / Basic error limit (operational limit at 25 °C) / Current, relative to input range, (+/-) | 0.6 % |
| Errors/accuracies / Basic error limit (operational limit at 25 °C) / Voltage, relative to output range, (+/-) | 0.5 % |
| Errors/accuracies / Basic error limit (operational limit at 25 °C) / Current, relative to output range, (+/-) | 0.5 % |
| Interrupts/diagnostics/status information / Alarms | No |
| Interrupts/diagnostics/status information / Diagnostics function | No |
| Potential separation / Potential separation analog inputs / between the channels and backplane bus | No |
| Potential separation / Potential separation analog outputs / between the channels | No |
| Potential separation / Potential separation analog outputs / between the channels and backplane bus | No |
| Potential separation / Potential separation analog outputs / between the channels and the power supply of the | Yes |
| Isolation / Isolation tested with | 500 V DC |
| Connection method / required front connector | 20-pin |
| Dimensions / Width | 40 mm |
| Dimensions / Height | 125 mm |
| Dimensions / Depth | 117 mm |
| Weights / Weight, approx. | 285 g |
| Product type designation | SM 334 |
| Number of poles | 20 |
Connections and conditions of use
- Encoder / Connection of signal encoders / for voltage measurement: Yes
- Encoder / Connection of signal encoders / for current measurement as 2-wire transducer: No
- Encoder / Connection of signal encoders / for current measurement as 4-wire transducer: Yes
- Connection method / required front connector: 20-pin
Scope of supply
We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.
Frequently asked questions
Is the same product family enough to identify a replacement?
The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.
What information is needed to check connections and accessories?
Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.
Can you assess a faulty part?
Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.
Why buy from FOXON
Replacement part availability
We will check current part availability and confirm the possible delivery date before you order.
New original and refurbished parts
We will specify the available version and condition of the particular unit in the quotation.
Parts with a warranty
We will confirm the warranty period according to the part condition and specific quotation.
Diagnostics and repairs
For a faulty unit, we will check the options for diagnostics and professional repair.
Part conditions available for sale
Part conditions and warranty
- New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
- New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
- New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
- New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
- Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
- Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
- Used (U): Functional used part. 3-month warranty.


Sales, repairs and buyback of automation parts
We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.
Need to buy or repair this part?
Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.
Request a quote for purchase or repairHighlighted items are mandatory.






