6ES7331-7SF00-0AB0, repair and sale of PLC / CNC SIEMENS

6ES7331-7SF00-0AB0, repair and sale of PLC / CNC SIEMENS

Sales, Repair, Purchase

SIEMENS

SIMATIC S7, ANALOG INPUT SM 331, OPTICALLY ISOLATATED, 8 AI THERMOCOUPLE/4 AI PT100, F. SIGNALS F. HAZARDOUS AREAS, CAPABLE OF DIAGNOST.,PTB-TESTED 1 X 20 PIN More

Code: 6ES7331-7SF00-0AB0

from 363 EUR excl. VAT (439,23 EUR Incl. VAT)
Total in stock: 204 pcs FOXON 1 pcs · External stock 203 pcs
Variant does not exist
pcs

Rezervace termínu

Get a quote
SIEMENS

SIMATIC S7, ANALOG INPUT SM 331, OPTICALLY ISOLATATED, 8 AI THERMOCOUPLE/4 AI PT100, F. SIGNALS F. HAZARDOUS AREAS, CAPABLE OF DIAGNOST.,PTB-TESTED 1 X 20 PIN More

Code: 6ES7331-7SF00-0AB0

Part Sales 3

Condition Code Warranty Availability Delivery
Express?
Price excl. VAT
New in sealed box (NC) 6ES7331-7SF00-0AB0 NC 12/24 months In external stock 9 pcs
Within 2-4 days / Express
On request
New without box (NW) 6ES7331-7SF00-0AB0 NW 12/24 months In stock FOXON 1 pcs
573 EUR
Refurbished (R) 6ES7331-7SF00-0AB0 R 12/24 months In external stock 194 pcs
Within 2-4 days / Express
On request

Repair of the part

Name Code Delivery Warranty Price excl. VAT
Complete part repair 6ES7331-7SF00-0AB0 O 3-6 weeks 24 months On request Enquire a repair

6ES7331-7SF00-0AB0 – SM 331

SIMATIC S7, analog input SM 331, isolated, 8 AI thermocouples/4 AI Pt100, for signals from the hazardous area, diagnostics- capable, PTB tested, 1 x 20-pole

Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.

Request a quote for purchase or repair
24 VSupply voltage / Load voltage L+ / Rated value (DC)
8; 8x thermocouples; 4x RTD thermoresistorsAnalog inputs / Number of analog inputs
200 m; TC: 50 mAnalog inputs / Cable length / shielded, max.

Application and selection

Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.

Technical specifications

ManufacturerSiemens
Order number6ES7331-7SF00-0AB0
Supply voltage / Load voltage L+ / Rated value (DC)24 V
Input current / from backplane bus 5 V DC, max.120 mA
Power loss / Power loss, typ.0.6 W
Analog inputs / Number of analog inputs8; 8x thermocouples; 4x RTD thermoresistors
Analog inputs / Input ranges / VoltageYes
Analog inputs / Input ranges / CurrentNo
Analog inputs / Input ranges / ThermocoupleYes
Analog inputs / Input ranges / Resistance thermometerYes
Analog inputs / Input ranges / ResistanceYes
Analog inputs / Input ranges (rated values), voltages / -1 V to +1 VYes
Analog inputs / Input ranges (rated values), voltages / Input resistance (-1 V to +1 V)10 MΩ
Analog inputs / Input ranges (rated values), voltages / -25 mV to +25 mVYes
Analog inputs / Input ranges (rated values), voltages / Input resistance (-25 mV to +25 mV)10 MΩ
Analog inputs / Input ranges (rated values), voltages / -250 mV to +250 mVYes
Analog inputs / Input ranges (rated values), voltages / Input resistance (-250 mV to +250 mV)10 MΩ
Analog inputs / Input ranges (rated values), voltages / -50 mV to +50 mVYes
Analog inputs / Input ranges (rated values), voltages / Input resistance (-50 mV to +50 mV)10 MΩ
Analog inputs / Input ranges (rated values), voltages / -500 mV to +500 mVYes
Analog inputs / Input ranges (rated values), voltages / Input resistance (-500 mV to +500 mV)10 MΩ
Analog inputs / Input ranges (rated values), voltages / -80 mV to +80 mVYes
Analog inputs / Input ranges (rated values), voltages / Input resistance (-80 mV to +80 mV)10 MΩ
Analog inputs / Input ranges (rated values), thermocouples / type BYes
Analog inputs / Input ranges (rated values), thermocouples / Input resistance (Type B)10 MΩ
Analog inputs / Input ranges (rated values), thermocouples / Type EYes
Analog inputs / Input ranges (rated values), thermocouples / Input resistance (Type E)10 MΩ
Analog inputs / Input ranges (rated values), thermocouples / Type JYes
Analog inputs / Input ranges (rated values), thermocouples / Input resistance (type J)10 MΩ
Analog inputs / Input ranges (rated values), thermocouples / Type KYes
Analog inputs / Input ranges (rated values), thermocouples / Input resistance (Type K)10 MΩ
Analog inputs / Input ranges (rated values), thermocouples / Type LYes
Analog inputs / Input ranges (rated values), thermocouples / Input resistance (Type L)10 MΩ
Analog inputs / Input ranges (rated values), thermocouples / Type NYes
Analog inputs / Input ranges (rated values), thermocouples / Input resistance (Type N)10 MΩ
Analog inputs / Input ranges (rated values), thermocouples / Type RYes
Analog inputs / Input ranges (rated values), thermocouples / Input resistance (Type R)10 MΩ
Analog inputs / Input ranges (rated values), thermocouples / Type SYes
Analog inputs / Input ranges (rated values), thermocouples / Input resistance (Type S)10 MΩ
Analog inputs / Input ranges (rated values), thermocouples / Type TYes
Analog inputs / Input ranges (rated values), thermocouples / Input resistance (Type T)10 MΩ
Analog inputs / Input ranges (rated values), thermocouples / Type UYes
Analog inputs / Input ranges (rated values), thermocouples / Input resistance (Type U)10 MΩ
Analog inputs / Input ranges (rated values), resistance thermometer / Ni 100Yes
Analog inputs / Input ranges (rated values), resistance thermometer / Input resistance (Ni 100)10 MΩ
Analog inputs / Input ranges (rated values), resistance thermometer / Pt 100Yes
Analog inputs / Input ranges (rated values), resistance thermometer / Input resistance (Pt 100)10 MΩ
Analog inputs / Input ranges (rated values), resistance thermometer / Pt 200Yes
Analog inputs / Input ranges (rated values), resistance thermometer / Input resistance (Pt 200)10 MΩ
Analog inputs / Cable length / shielded, max.200 m; TC: 50 m
Analog value generation for the inputs / Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max.16 bit; 10 bit to 15 bit + sign
Analog value generation for the inputs / Integration and conversion time/resolution per channel / Integration time, parameterizableYes; 2.5 to 100 ms
Analog value generation for the inputs / Integration and conversion time/resolution per channel / Interference voltage suppression for interference10 to 400 Hz
Encoder / Connection of signal encoders / for current measurement as 2-wire transducerYes
Encoder / Connection of signal encoders / for current measurement as 4-wire transducerYes
Errors/accuracies / Operational error limit in overall temperature range / Resistance thermometer, relative to input range, (+/-)0.04 %; 0.09 to 0.04%
Errors/accuracies / Basic error limit (operational limit at 25 °C) / Resistance thermometer, relative to input range, (+/-)0.008 %; 0.018 ... 0.008%
Interrupts/diagnostics/status information / Diagnostics functionYes
Interrupts/diagnostics/status information / Diagnoses / Diagnostic information readableYes
Interrupts/diagnostics/status information / Diagnoses / OverrangeYes
Interrupts/diagnostics/status information / Diagnoses / Wire-break in signal transmitter cableYes
Interrupts/diagnostics/status information / Diagnoses / Short-circuit of the signal encoder cableYes
Interrupts/diagnostics/status information / Diagnostics indication LED / Group error SF (red)Yes
Interrupts/diagnostics/status information / Diagnostics indication LED / Channel fault indicator F (red)Yes
Ex(i) characteristics / Module for Ex(i) protectionYes
Ex(i) characteristics / maximum values for connecting terminals for gas group IIC / Uo (no-load voltage), max.5.9 V
Ex(i) characteristics / maximum values for connecting terminals for gas group IIC / Io (short-circuit current), max.28.8 mA
Ex(i) characteristics / maximum values for connecting terminals for gas group IIC / Po (power output), max.41.4 mW
Ex(i) characteristics / maximum values for connecting terminals for gas group IIC / Co (permissible external capacity), max.43 µF
Ex(i) characteristics / maximum values for connecting terminals for gas group IIC / Lo (permissible external inductivity), max.40 mH
Potential separation / Potential separation analog inputs / between the channelsNo
Potential separation / Potential separation analog inputs / between the channels and backplane busYes
Ambient conditions / Ambient temperature during operation / max.60 °C
Connection method / required front connector20-pin
Weights / Weight, approx.210 g
Product type designationSM 331
Number of poles20

Supported signals and ranges

  • Supply voltage / Load voltage L+ / Rated value (DC): 24 V
  • Analog inputs / Input ranges / Voltage: Yes
  • Analog inputs / Input ranges / Current: No
  • Analog inputs / Input ranges / Thermocouple: Yes
  • Analog inputs / Input ranges / Resistance thermometer: Yes
  • Analog inputs / Input ranges / Resistance: Yes
  • Analog inputs / Input ranges (rated values), voltages / -1 V to +1 V: Yes
  • Analog inputs / Input ranges (rated values), voltages / Input resistance (-1 V to +1 V): 10 MΩ

Scope of supply

We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.

Frequently asked questions

Is the same product family enough to identify a replacement?

The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.

What information is needed to check connections and accessories?

Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.

Can you assess a faulty part?

Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.

Why buy from FOXON

1

Replacement part availability

We will check current part availability and confirm the possible delivery date before you order.

2

New original and refurbished parts

We will specify the available version and condition of the particular unit in the quotation.

3

Parts with a warranty

We will confirm the warranty period according to the part condition and specific quotation.

4

Diagnostics and repairs

For a faulty unit, we will check the options for diagnostics and professional repair.

More than 3,500customers
We deliver tomore than 100 countries
Express delivery?We will check. Contact us now.

Part conditions available for sale

Part conditions and warranty
  • New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
  • New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
  • New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
  • New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
  • Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
  • Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
  • Used (U): Functional used part. 3-month warranty.

Sales, repairs and buyback of automation parts

We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.

More about parts sales, repairs and buyback

Need to buy or repair this part?

Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.

Request a quote for purchase or repair