6ES7321-7RD00-0AB0, repair and sale of PLC / CNC SIEMENS

6ES7321-7RD00-0AB0, repair and sale of PLC / CNC SIEMENS

Sales, Repair, Purchase

SIEMENS

SIMATIC S7, DIGITAL INPUT SM 321, OPTICALLY ISOLATED, 4 DI, 24V DC, NAMUR/DIN 19234, F. SIGNALS F HAZARDOUS AREAS, CAPABLE OF DIAGNOST.,PTB-TESTED More

Code: 6ES7321-7RD00-0AB0

from 183 EUR excl. VAT (221,43 EUR Incl. VAT)
Total in stock: 69 pcs External stock 69 pcs
Variant does not exist

Rezervace termínu

Get a quote
SIEMENS

SIMATIC S7, DIGITAL INPUT SM 321, OPTICALLY ISOLATED, 4 DI, 24V DC, NAMUR/DIN 19234, F. SIGNALS F HAZARDOUS AREAS, CAPABLE OF DIAGNOST.,PTB-TESTED More

Code: 6ES7321-7RD00-0AB0

Part Sales 2

Condition Code Warranty Availability Delivery
Express?
Price excl. VAT
New in sealed box (NC) 6ES7321-7RD00-0AB0 NC 12/24 months In external stock 9 pcs
Within 2-4 days / Express
On request
Refurbished (R) 6ES7321-7RD00-0AB0 R 12/24 months In external stock 60 pcs
Within 2-4 days / Express
On request

Repair of the part

Name Code Delivery Warranty Price excl. VAT
Complete part repair 6ES7321-7RD00-0AB0 O 3-6 weeks 24 months On request Enquire a repair

6ES7321-7RD00-0AB0 – SM 321

SIMATIC S7, digital input SM 321, isolated, 4 DI; 24 V DC, NAMUR/DIN 19234, for signals from the hazardous area, diagnostics-capable, PTB tested

Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.

Request a quote for purchase or repair
24 VSupply voltage / Load voltage L+ / Rated value (DC)
YesSupply voltage / Load voltage L+ / Reverse polarity protection
4Digital inputs / Number of digital inputs

Application and selection

Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.

Technical specifications

ManufacturerSiemens
Order number6ES7321-7RD00-0AB0
Supply voltage / Load voltage L+ / Rated value (DC)24 V
Supply voltage / Load voltage L+ / Reverse polarity protectionYes
Input current / from load voltage L+ (without load), max.50 mA
Input current / from backplane bus 5 V DC, max.80 mA
Encoder supply / Type of output voltagevia the inputs
Power loss / Power loss, typ.1.1 W
Digital inputs / Number of digital inputs4
Digital inputs / Number of NAMUR inputs4
Digital inputs / Input voltage / Type of input voltageDC
Digital inputs / Input voltage / Rated value (DC)8.2 V; from internal power circuit supply
Digital inputs / Input current / on wire-break, max.0.1 mA
Digital inputs / Input current / on short-circuit, max. for NAMUR encoders8.5 mA
Digital inputs / Input current / for signal "0", min.0.35 mA
Digital inputs / Input current / for signal "0", max.1.2 mA
Digital inputs / Input current / for signal "1", min.2.1 mA
Digital inputs / Input current / for signal "1", max.7 mA
Digital inputs / Input delay (for rated value of input voltage) / Input frequency (with a time delay of 0.1 ms), max. for NAMUR inputs2 kHz
Digital inputs / Input delay (for rated value of input voltage) / ParameterizableYes; 0.1 / 0.5 / 3 / 15 / 20 ms (plus 0.25 ms preparation time)
Digital inputs / Cable length / unshielded, max.200 m
Encoder / Connectable encoders / NAMUR encoderYes; Two-wire connection
Interrupts/diagnostics/status information / Diagnostics functionYes
Interrupts/diagnostics/status information / Diagnoses / Diagnostic information readableYes
Interrupts/diagnostics/status information / Diagnostics indication LED / Group error SF (red)Yes
Interrupts/diagnostics/status information / Diagnostics indication LED / Status indicator digital input (green)Yes
Interrupts/diagnostics/status information / Diagnostics indication LED / Channel fault indicator F (red)Yes
Ex(i) characteristics / Module for Ex(i) protectionYes
Ex(i) characteristics / maximum values for connecting terminals for gas group IIC / Uo (no-load voltage), max.10 V
Ex(i) characteristics / maximum values for connecting terminals for gas group IIC / Io (short-circuit current), max.14.1 mA
Ex(i) characteristics / maximum values for connecting terminals for gas group IIC / Po (power output), max.33.7 mW
Ex(i) characteristics / maximum values for connecting terminals for gas group IIC / Co (permissible external capacity), max.3 µF
Ex(i) characteristics / maximum values for connecting terminals for gas group IIC / Lo (permissible external inductivity), max.100 mH
Potential separation / Potential separation digital inputs / between the channelsYes; 60 V DC/30 V AC when used in the hazardous area; 400 V DC/250 V AC when used in NON-hazardous area
Potential separation / Potential separation digital inputs / between the channels, in groups of1
Potential separation / Potential separation digital inputs / between the channels and backplane busYes; 60 V DC/30 V AC when used in the hazardous area; 400 V DC/250 V AC when used in NON-hazardous area
Potential separation / Potential separation digital inputs / Between the channels and load voltage L+Yes; 60 V DC/30 V AC when used in the hazardous area; 400 V DC/250 V AC when used in NON-hazardous area
Ambient conditions / Ambient temperature during operation / max.60 °C
Connection method / required front connector20-pin
Dimensions / Width40 mm
Dimensions / Height125 mm
Dimensions / Depth120 mm
Weights / Weight, approx.230 g
Product type designationSM 321

Connections and conditions of use

  • Digital inputs / Input current / for signal "0", min.: 0.35 mA
  • Digital inputs / Input current / for signal "0", max.: 1.2 mA
  • Digital inputs / Input current / for signal "1", min.: 2.1 mA
  • Digital inputs / Input current / for signal "1", max.: 7 mA
  • Connection method / required front connector: 20-pin

Scope of supply

We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.

Frequently asked questions

Is the same product family enough to identify a replacement?

The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.

What information is needed to check connections and accessories?

Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.

Can you assess a faulty part?

Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.

Why buy from FOXON

1

Replacement part availability

We will check current part availability and confirm the possible delivery date before you order.

2

New original and refurbished parts

We will specify the available version and condition of the particular unit in the quotation.

3

Parts with a warranty

We will confirm the warranty period according to the part condition and specific quotation.

4

Diagnostics and repairs

For a faulty unit, we will check the options for diagnostics and professional repair.

More than 3,500customers
We deliver tomore than 100 countries
Express delivery?We will check. Contact us now.

Part conditions available for sale

Part conditions and warranty
  • New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
  • New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
  • New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
  • New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
  • Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
  • Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
  • Used (U): Functional used part. 3-month warranty.

Sales, repairs and buyback of automation parts

We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.

More about parts sales, repairs and buyback

Need to buy or repair this part?

Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.

Request a quote for purchase or repair