from 269,83 EUR Incl. VAT
6ES7322-5FF00-0AB0
- SIEMENS
- SIMATIC S7-300
- Digital Outputs
- 6ES7322-5FF00-0AB0
6ES7322-5FF00-0AB0
SIMATIC S7-300, Digital output SM 322, isolated, 8 DO, 120/230 V AC, 2A, with single rooting/channel and selectable failure mode, 1x 40-pole More
Code: 6ES7322-5FF00-0AB0
SIMATIC S7-300, Digital output SM 322, isolated, 8 DO, 120/230 V AC, 2A, with single rooting/channel and selectable failure mode, 1x 40-pole More
Code: 6ES7322-5FF00-0AB0
Part Sales 3
| Condition | Code | Warranty | Availability |
Delivery Express? | Price excl. VAT | |
|---|---|---|---|---|---|---|
| New in sealed box (NC) | 6ES7322-5FF00-0AB0 NC | 12/24 months | In external stock 2 pcs |
Within 2-4 days / Express
|
On request
|
|
| Refurbished (R) | 6ES7322-5FF00-0AB0 R | 12/24 months | In external stock 14 pcs |
Within 2-4 days / Express
|
On request
|
|
| Used (U) | 6ES7322-5FF00-0AB0 U | 3 months | In external stock 1 pcs |
Within 2-4 days / Express
|
On request
|
Repair of the part
| Name | Code | Delivery | Warranty | Price excl. VAT | |
|---|---|---|---|---|---|
| Complete part repair | 6ES7322-5FF00-0AB0 O | 3-6 weeks | 24 months | On request | Enquire a repair |
6ES7322-5FF00-0AB0 – SM 322
SIMATIC S7-300, digital output SM 322, isolated, 8 DO, 120/230 V AC, 2 A, with single-point grounding/channel and selectable failure mode, 1x 40- pole
Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.
Application and selection
Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.
Technical specifications
| Manufacturer | Siemens |
|---|---|
| Order number | 6ES7322-5FF00-0AB0 |
| Supply voltage / Load voltage L1 / Rated value (AC) | 230 V; 120/230 V AC |
| Supply voltage / Load voltage L1 / permissible range, lower limit (AC) | 79 V |
| Supply voltage / Load voltage L1 / permissible range, upper limit (AC) | 264 V |
| Input current / from load voltage L1 (without load), max. | 2 mA |
| Input current / from backplane bus 5 V DC, max. | 100 mA |
| Power loss / Power loss, typ. | 8.6 W |
| Digital outputs / Number of digital outputs | 8 |
| Digital outputs / Short-circuit protection | Yes; to be provided externally; fuse 3.15 A / 250 V, quick response |
| Digital outputs / Controlling a digital input | Yes |
| Digital outputs / Size of motor starters according to NEMA, max. | Size 5 according to NEMA |
| Digital outputs / Zero-crossing switch | Yes; 60 V |
| Digital outputs / Switching capacity of the outputs / on lamp load, max. | 50 W |
| Digital outputs / Output voltage / for signal "1", min. | L1 (-8.5 V) |
| Digital outputs / Output current / for signal "1" rated value | 2 A |
| Digital outputs / Output current / for signal "1" permissible range for 0 to 40 °C, min. | 10 mA |
| Digital outputs / Output current / for signal "1" permissible range for 0 to 40 °C, max. | 2 A |
| Digital outputs / Output current / for signal "1" permissible range for 40 to 60 °C, min. | 10 mA |
| Digital outputs / Output current / for signal "1" permissible range for 40 to 60 °C, max. | 1 A |
| Digital outputs / Output current / for signal "1" minimum load current | 10 mA |
| Digital outputs / Output current / for signal "1" permissible surge current, max. | 20 A; with 2 half waves |
| Digital outputs / Output current / for signal "0" residual current, max. | 2 mA |
| Digital outputs / Parallel switching of two outputs / for uprating | No |
| Digital outputs / Parallel switching of two outputs / for redundant control of a load | Yes |
| Digital outputs / Switching frequency / with resistive load, max. | 10 Hz |
| Digital outputs / Switching frequency / with inductive load, max. | 0.5 Hz |
| Digital outputs / Switching frequency / with inductive load (acc. to IEC 60947-5-1, AC15), max. | 0.5 Hz |
| Digital outputs / Switching frequency / on lamp load, max. | 1 Hz |
| Digital outputs / Total current of the outputs (per group) / horizontal installation / up to 40 °C, max. | 8 A |
| Digital outputs / Total current of the outputs (per group) / horizontal installation / up to 60 °C, max. | 4 A |
| Digital outputs / Total current of the outputs (per group) / vertical installation / up to 40 °C, max. | 4 A |
| Digital outputs / Cable length / shielded, max. | 1 000 m |
| Digital outputs / Cable length / unshielded, max. | 600 m |
| Interrupts/diagnostics/status information / Diagnostics function | Yes; Parameterizable |
| Interrupts/diagnostics/status information / Alarms / Diagnostic alarm | Yes; Parameterizable |
| Interrupts/diagnostics/status information / Diagnostics indication LED / Group error SF (red) | Yes |
| Interrupts/diagnostics/status information / Diagnostics indication LED / Status indicator digital output (green) | Yes |
| Potential separation / Potential separation digital outputs / between the channels | Yes |
| Potential separation / Potential separation digital outputs / between the channels, in groups of | 1 |
| Potential separation / Potential separation digital outputs / between the channels and backplane bus | Yes; Optocoupler |
| Isolation / Isolation tested with | 1 500 V AC |
| Connection method / required front connector | 40-pin |
| Dimensions / Width | 40 mm |
| Dimensions / Height | 125 mm |
| Dimensions / Depth | 120 mm |
| Weights / Weight, approx. | 275 g |
| Product type designation | SM 322 |
Connections and conditions of use
- Digital outputs / Output voltage / for signal "1", min.: L1 (-8.5 V)
- Digital outputs / Output current / for signal "1" rated value: 2 A
- Digital outputs / Output current / for signal "1" permissible range for 0 to 40 °C, min.: 10 mA
- Digital outputs / Output current / for signal "1" permissible range for 0 to 40 °C, max.: 2 A
- Digital outputs / Output current / for signal "1" permissible range for 40 to 60 °C, min.: 10 mA
- Digital outputs / Output current / for signal "1" permissible range for 40 to 60 °C, max.: 1 A
- Digital outputs / Output current / for signal "1" minimum load current: 10 mA
- Digital outputs / Output current / for signal "1" permissible surge current, max.: 20 A; with 2 half waves
Scope of supply
We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.
Frequently asked questions
Is the same product family enough to identify a replacement?
The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.
What information is needed to check connections and accessories?
Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.
Can you assess a faulty part?
Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.
Why buy from FOXON
Replacement part availability
We will check current part availability and confirm the possible delivery date before you order.
New original and refurbished parts
We will specify the available version and condition of the particular unit in the quotation.
Parts with a warranty
We will confirm the warranty period according to the part condition and specific quotation.
Diagnostics and repairs
For a faulty unit, we will check the options for diagnostics and professional repair.
Part conditions available for sale
Part conditions and warranty
- New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
- New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
- New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
- New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
- Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
- Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
- Used (U): Functional used part. 3-month warranty.


Sales, repairs and buyback of automation parts
We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.
Need to buy or repair this part?
Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.
Request a quote for purchase or repairHighlighted items are mandatory.