6ES7322-1HH01-0AA0

6ES7322-1HH01-0AA0

Sales, Repair, Purchase

SIEMENS

SIMATIC S7-300, Digital output SM 322, Isolated 16 DO, relay contacts, 1x 20-pole More

Code: 6ES7322-1HH01-0AA0

from 230 EUR excl. VAT (278,30 EUR Incl. VAT)
Total in stock: 81 pcs External stock 81 pcs
Variant does not exist

Rezervace termínu

Get a quote
SIEMENS

SIMATIC S7-300, Digital output SM 322, Isolated 16 DO, relay contacts, 1x 20-pole More

Code: 6ES7322-1HH01-0AA0

Part Sales 2

Condition Code Warranty Availability Delivery
Express?
Price excl. VAT
New in sealed box (NC) 6ES7322-1HH01-0AA0 NC 12/24 months In external stock 7 pcs
Within 2-4 days / Express
On request
Refurbished (R) 6ES7322-1HH01-0AA0 R 12/24 months In external stock 74 pcs
Within 2-4 days / Express
On request

Repair of the part

Name Code Delivery Warranty Price excl. VAT
Complete part repair 6ES7322-1HH01-0AA0 O 3-6 weeks 24 months On request Enquire a repair

6ES7322-1HH01-0AA0 – SM 322

SIMATIC S7-300, digital output SM 322, isolated 16 DO, relay contacts, 1x 20-pole

Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.

Request a quote for purchase or repair
120 VSupply voltage / Load voltage L+ / Rated value (DC)
230 VSupply voltage / Load voltage L1 / Rated value (AC)
250 mAInput current / from supply voltage L+, max.

Application and selection

Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.

Technical specifications

ManufacturerSiemens
Order number6ES7322-1HH01-0AA0
Supply voltage / Load voltage L+ / Rated value (DC)120 V
Supply voltage / Load voltage L1 / Rated value (AC)230 V
Input current / from supply voltage L+, max.250 mA
Input current / from backplane bus 5 V DC, max.100 mA
Power loss / Power loss, typ.4.5 W
Digital outputs / Number of digital outputs16; Relays
Digital outputs / Short-circuit protectionNo
Digital outputs / Controlling a digital inputYes
Digital outputs / Size of motor starters according to NEMA, max.Size 5 according to NEMA
Digital outputs / Switching capacity of the outputs / on lamp load, max.50 W; 230 V AC
Digital outputs / Output current / for signal "1" rated value2 A
Digital outputs / Output current / for signal "1" minimum load current10 mA
Digital outputs / Parallel switching of two outputs / for upratingNo
Digital outputs / Parallel switching of two outputs / for redundant control of a loadYes
Digital outputs / Switching frequency / with resistive load, max.1 Hz
Digital outputs / Switching frequency / with inductive load, max.0.5 Hz
Digital outputs / Switching frequency / With inductive load (to IEC 60947-5-1, DC13/AC15), max.0.5 Hz
Digital outputs / Switching frequency / on lamp load, max.1 Hz
Digital outputs / Switching frequency / mechanical, max.10 Hz
Digital outputs / Total current of the outputs (per group) / horizontal installation / up to 60 °C, max.8 A
Digital outputs / Total current of the outputs (per group) / vertical installation / up to 40 °C, max.8 A
Digital outputs / Relay outputs / Rated supply voltage of relay coil L+ (DC)24 V
Digital outputs / Relay outputs / Contact connection (internal)No
Digital outputs / Relay outputs / Number of operating cycles, max.100 000; 50 000 (24 V DC, at 2 A); 700 000 (120 V AC, at 2 A); 100 000 (230 V AC, at 2 A)
Digital outputs / Relay outputs / Switching capacity of contacts / with inductive load, max.2 A; 2 A (230 V AC), 2 A (24 V DC)
Digital outputs / Relay outputs / Switching capacity of contacts / with resistive load, max.2 A; 2 A (230 V AC), 2 A (24 V DC)
Digital outputs / Relay outputs / Switching capacity of contacts / Thermal continuous current, max.2 A
Digital outputs / Cable length / shielded, max.1 000 m
Digital outputs / Cable length / unshielded, max.600 m
Interrupts/diagnostics/status information / AlarmsNo
Interrupts/diagnostics/status information / Diagnostics functionNo
Interrupts/diagnostics/status information / Alarms / Diagnostic alarmNo
Interrupts/diagnostics/status information / Diagnoses / Wire breakNo
Interrupts/diagnostics/status information / Diagnoses / Short-circuitNo
Interrupts/diagnostics/status information / Diagnoses / Fuse blownNo
Interrupts/diagnostics/status information / Diagnoses / Missing load voltageNo
Interrupts/diagnostics/status information / Diagnostics indication LED / Rated load voltage PWR (green)No
Interrupts/diagnostics/status information / Diagnostics indication LED / Fuse OK FSG (green)No
Interrupts/diagnostics/status information / Diagnostics indication LED / Status indicator digital output (green)Yes
Potential separation / Potential separation digital outputs / between the channelsYes
Potential separation / Potential separation digital outputs / between the channels, in groups of8
Potential separation / Potential separation digital outputs / between the channels and backplane busYes; Optocoupler
Isolation / Isolation tested with1 500 V AC
Connection method / required front connector20-pin
Dimensions / Width40 mm
Dimensions / Height125 mm
Dimensions / Depth120 mm
Weights / Weight, approx.250 g
Product type designationSM 322
Number of poles20

Connections and conditions of use

  • Digital outputs / Output current / for signal "1" rated value: 2 A
  • Digital outputs / Output current / for signal "1" minimum load current: 10 mA
  • Digital outputs / Relay outputs / Contact connection (internal): No
  • Connection method / required front connector: 20-pin

Scope of supply

We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.

Frequently asked questions

Is the same product family enough to identify a replacement?

The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.

What information is needed to check connections and accessories?

Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.

Can you assess a faulty part?

Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.

Why buy from FOXON

1

Replacement part availability

We will check current part availability and confirm the possible delivery date before you order.

2

New original and refurbished parts

We will specify the available version and condition of the particular unit in the quotation.

3

Parts with a warranty

We will confirm the warranty period according to the part condition and specific quotation.

4

Diagnostics and repairs

For a faulty unit, we will check the options for diagnostics and professional repair.

More than 3,500customers
We deliver tomore than 100 countries
Express delivery?We will check. Contact us now.

Part conditions available for sale

Part conditions and warranty
  • New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
  • New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
  • New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
  • New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
  • Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
  • Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
  • Used (U): Functional used part. 3-month warranty.

Sales, repairs and buyback of automation parts

We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.

More about parts sales, repairs and buyback

Need to buy or repair this part?

Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.

Request a quote for purchase or repair