6ES7 331-7KB02-0AB0
- SIEMENS
- SIMATIC S7-300
- Analog Inputs
- 6ES7 331-7KB02-0AB0
6ES7 331-7KB02-0AB0
SIMATIC S7-300, analog input SM 331, isolated, 2 AI, resolution 9/12/14 bits, U/I/thermocouple/resistor, alarm, diagnostics, 1x 20-pole, removing/inserting with active backplane bus More
Code: 6ES7 331-7KB02-0AB0
SIMATIC S7-300, analog input SM 331, isolated, 2 AI, resolution 9/12/14 bits, U/I/thermocouple/resistor, alarm, diagnostics, 1x 20-pole, removing/inserting with active backplane bus More
Code: 6ES7 331-7KB02-0AB0
Part Sales 1
| Condition | Code | Warranty | Availability |
Delivery Express? | Price excl. VAT | |
|---|---|---|---|---|---|---|
| Used (U) | 6ES7 331-7KB02-0AB0 U | 3 months | In external stock 1 pcs |
Within 2-4 days / Express
|
On request
|
Repair of the part
| Name | Code | Delivery | Warranty | Price excl. VAT | |
|---|---|---|---|---|---|
| Complete part repair | 6ES7 331-7KB02-0AB0 O | 3-6 weeks | 24 months | On request | Enquire a repair |
6ES7331-7KB02-0AB0 – SM 331
SIMATIC S7-300, analog input SM 331, isolated, 2 AI, resolution 9/12/14 bits, U/I/thermocouple/resistor, alarm, diagnostics, 1x 20-pole, removing/inserting with active backplane bus
Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.
Application and selection
Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.
Technical specifications
| Manufacturer | Siemens |
|---|---|
| Order number | 6ES7331-7KB02-0AB0 |
| General information / Product function / Isochronous mode | No |
| Supply voltage / Load voltage L+ / Rated value (DC) | 24 V |
| Supply voltage / Load voltage L+ / Reverse polarity protection | Yes |
| Input current / from load voltage L+ (without load), max. | 30 mA |
| Input current / from backplane bus 5 V DC, max. | 50 mA |
| Power loss / Power loss, typ. | 1 W |
| Analog inputs / Number of analog inputs | 2 |
| Analog inputs / For resistance measurement | 1 |
| Analog inputs / permissible input voltage for voltage input (destruction limit), | 20 V; continuous; 75 V for max. 1 s (mark to space ratio 1:20) |
| Analog inputs / permissible input current for current input (destruction limit), | 40 mA |
| Analog inputs / Constant measurement current for resistance-type transmitter, | 1.67 mA |
| Analog inputs / Input ranges / Voltage | Yes |
| Analog inputs / Input ranges / Current | Yes |
| Analog inputs / Input ranges / Thermocouple | Yes |
| Analog inputs / Input ranges / Resistance thermometer | Yes |
| Analog inputs / Input ranges / Resistance | Yes |
| Analog inputs / Input ranges (rated values), voltages / 0 to +10 V | No |
| Analog inputs / Input ranges (rated values), voltages / 1 V to 5 V | Yes |
| Analog inputs / Input ranges (rated values), voltages / Input resistance (1 V to 5 V) | 100 kΩ |
| Analog inputs / Input ranges (rated values), voltages / 1 V to 10 V | No |
| Analog inputs / Input ranges (rated values), voltages / -1 V to +1 V | Yes |
| Analog inputs / Input ranges (rated values), voltages / Input resistance (-1 V to +1 V) | 10 MΩ |
| Analog inputs / Input ranges (rated values), voltages / -10 V to +10 V | Yes |
| Analog inputs / Input ranges (rated values), voltages / Input resistance (-10 V to +10 V) | 100 kΩ |
| Analog inputs / Input ranges (rated values), voltages / -2.5 V to +2.5 V | Yes |
| Analog inputs / Input ranges (rated values), voltages / Input resistance (-2.5 V to +2.5 V) | 100 kΩ |
| Analog inputs / Input ranges (rated values), voltages / -250 mV to +250 mV | Yes |
| Analog inputs / Input ranges (rated values), voltages / Input resistance (-250 mV to +250 mV) | 10 MΩ |
| Analog inputs / Input ranges (rated values), voltages / -5 V to +5 V | Yes |
| Analog inputs / Input ranges (rated values), voltages / Input resistance (-5 V to +5 V) | 100 kΩ |
| Analog inputs / Input ranges (rated values), voltages / -50 mV to +50 mV | No |
| Analog inputs / Input ranges (rated values), voltages / -500 mV to +500 mV | Yes |
| Analog inputs / Input ranges (rated values), voltages / Input resistance (-500 mV to +500 mV) | 10 MΩ |
| Analog inputs / Input ranges (rated values), voltages / -80 mV to +80 mV | Yes |
| Analog inputs / Input ranges (rated values), voltages / Input resistance (-80 mV to +80 mV) | 10 MΩ |
| Analog inputs / Input ranges (rated values), currents / 0 to 20 mA | Yes |
| Analog inputs / Input ranges (rated values), currents / Input resistance (0 to 20 mA) | 25 Ω |
| Analog inputs / Input ranges (rated values), currents / -10 mA to +10 mA | Yes |
| Analog inputs / Input ranges (rated values), currents / Input resistance (-10 mA to +10 mA) | 25 Ω |
| Analog inputs / Input ranges (rated values), currents / -20 mA to +20 mA | Yes |
| Analog inputs / Input ranges (rated values), currents / Input resistance (-20 mA to +20 mA) | 25 Ω |
| Analog inputs / Input ranges (rated values), currents / -3.2 mA to +3.2 mA | Yes |
| Analog inputs / Input ranges (rated values), currents / Input resistance (-3.2 mA to +3.2 mA) | 25 Ω |
| Analog inputs / Input ranges (rated values), currents / 4 mA to 20 mA | Yes |
| Analog inputs / Input ranges (rated values), currents / Input resistance (4 mA to 20 mA) | 25 Ω |
| Analog inputs / Input ranges (rated values), thermocouples / Type B | No |
| Analog inputs / Input ranges (rated values), thermocouples / Type E | Yes |
| Analog inputs / Input ranges (rated values), thermocouples / Input resistance (Type E) | 10 MΩ |
| Analog inputs / Input ranges (rated values), thermocouples / Type J | Yes |
| Analog inputs / Input ranges (rated values), thermocouples / Input resistance (type J) | 10 MΩ |
| Analog inputs / Input ranges (rated values), thermocouples / Type K | Yes |
| Analog inputs / Input ranges (rated values), thermocouples / Input resistance (Type K) | 10 MΩ |
| Analog inputs / Input ranges (rated values), thermocouples / Type L | No |
| Analog inputs / Input ranges (rated values), thermocouples / Type N | Yes |
| Analog inputs / Input ranges (rated values), thermocouples / Input resistance (Type N) | 10 MΩ |
| Analog inputs / Input ranges (rated values), thermocouples / Type R | No |
| Analog inputs / Input ranges (rated values), thermocouples / Type S | No |
| Analog inputs / Input ranges (rated values), thermocouples / Type T | No |
| Analog inputs / Input ranges (rated values), thermocouples / Type U | No |
| Analog inputs / Input ranges (rated values), thermocouples / Type TXK/TXK(L) to GOST | No |
| Analog inputs / Input ranges (rated values), resistance thermometer / Cu 10 | No |
| Analog inputs / Input ranges (rated values), resistance thermometer / Ni 100 | Yes |
| Analog inputs / Input ranges (rated values), resistance thermometer / Input resistance (Ni 100) | 10 MΩ; Standard |
| Analog inputs / Input ranges (rated values), resistance thermometer / Ni 1000 | No |
| Analog inputs / Input ranges (rated values), resistance thermometer / LG-Ni 1000 | No |
| Analog inputs / Input ranges (rated values), resistance thermometer / Ni 120 | No |
| Analog inputs / Input ranges (rated values), resistance thermometer / Ni 200 | No |
| Analog inputs / Input ranges (rated values), resistance thermometer / Ni 500 | No |
| Analog inputs / Input ranges (rated values), resistance thermometer / Pt 100 | Yes |
| Analog inputs / Input ranges (rated values), resistance thermometer / Input resistance (Pt 100) | 10 kΩ; Standard |
| Analog inputs / Input ranges (rated values), resistance thermometer / Pt 1000 | No |
| Analog inputs / Input ranges (rated values), resistance thermometer / Pt 200 | No |
| Analog inputs / Input ranges (rated values), resistance thermometer / Pt 500 | No |
| Analog inputs / Input ranges (rated values), resistors / 0 to 150 ohms | Yes |
| Analog inputs / Input ranges (rated values), resistors / Input resistance (0 to 150 ohms) | 10 MΩ |
| Analog inputs / Input ranges (rated values), resistors / 0 to 300 ohms | Yes |
| Analog inputs / Input ranges (rated values), resistors / Input resistance (0 to 300 ohms) | 10 MΩ |
| Analog inputs / Input ranges (rated values), resistors / 0 to 600 ohms | Yes |
| Analog inputs / Input ranges (rated values), resistors / Input resistance (0 to 600 ohms) | 10 MΩ |
| Analog inputs / Input ranges (rated values), resistors / 0 to 6000 ohms | No |
| Analog inputs / Thermocouple (TC) / Temperature compensation / Parameterizable | Yes |
| Analog inputs / Thermocouple (TC) / Temperature compensation / internal temperature compensation | Yes |
| Analog inputs / Thermocouple (TC) / Temperature compensation / external temperature compensation with | Yes |
| Analog inputs / Thermocouple (TC) / Temperature compensation / for definable comparison point temperature | Yes |
| Analog inputs / Thermocouple (TC) / Characteristic linearization / Parameterizable | Yes |
| Analog inputs / Thermocouple (TC) / Characteristic linearization / for thermocouples | Type E, J, K, L, N |
| Analog inputs / Thermocouple (TC) / Characteristic linearization / for resistance thermometer | Pt100 (standard, climatic range), Ni100 (standard, climatic range) |
| Analog inputs / Thermocouple (TC) / Cable length / shielded, max. | 200 m; 50 m at 80 mV and thermocouples |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max. | 15 bit; Unipolar: 9/12/12/14 bit; bipolar: 9 bit + sign/12 bit + sign/12 bit + sign/14 bit + sign |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Integration time, parameterizable | Yes; 2,5 / 16,67 / 20 / 100 ms |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Basic conversion time (ms) | 3 / 17 / 22 / 102 ms |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Interference voltage suppression for interference | 400 / 60 / 50 / 10 Hz |
| Encoder / Connection of signal encoders / for voltage measurement | Yes |
| Encoder / Connection of signal encoders / for current measurement as 2-wire transducer | Yes |
| Encoder / Connection of signal encoders / for current measurement as 4-wire transducer | Yes |
| Encoder / Connection of signal encoders / for resistance measurement with two-wire connection | Yes |
| Encoder / Connection of signal encoders / for resistance measurement with three-wire connection | Yes |
| Encoder / Connection of signal encoders / for resistance measurement with four-wire connection | Yes |
| Errors/accuracies / Operational error limit in overall temperature range / Voltage, relative to input range, (+/-) | 1 %; ±1% (80 mV); ±0.6% (250 mV to 1 000 mV); ±0.8% (2.5 V to 10 V) |
| Errors/accuracies / Operational error limit in overall temperature range / Current, relative to input range, (+/-) | 0.7 %; From 3.2 to 20 mA |
| Errors/accuracies / Operational error limit in overall temperature range / Resistance, relative to input range, (+/-) | 0.7 %; 150, 300, 600 Ohm |
| Errors/accuracies / Operational error limit in overall temperature range / Resistance thermometer, relative to input range, (+/-) | 0.7 %; ±0.7 % (Pt100/ Ni100); ±0.8 % (Pt100 climate) |
| Errors/accuracies / Operational error limit in overall temperature range / Thermocouple, relative to input range, (+/-) | 1.1 %; Type E, J, K, L, N |
| Errors/accuracies / Basic error limit (operational limit at 25 °C) / Voltage, relative to input range, (+/-) | 0.6 %; ±0.6% (80 mV, 2.5 V to 10 V); ±0.4% (250 mV to 1 000 mV) |
| Errors/accuracies / Basic error limit (operational limit at 25 °C) / Current, relative to input range, (+/-) | 0.5 %; 3.2 to 20 mA |
| Errors/accuracies / Basic error limit (operational limit at 25 °C) / Resistance, relative to input range, (+/-) | 0.5 %; 150, 300, 600 Ohm |
| Errors/accuracies / Basic error limit (operational limit at 25 °C) / Resistance thermometer, relative to input range, (+/-) | 0.6 %; ±0.5% (Pt100/ Ni100), ±0.6% (Pt100 climate) |
| Errors/accuracies / Basic error limit (operational limit at 25 °C) / Thermocouple, relative to input range, (+/-) | 0.7 %; Type E, N, J, K, L |
| Interrupts/diagnostics/status information / Diagnostics function | Yes; Parameterizable |
| Interrupts/diagnostics/status information / Alarms / Diagnostic alarm | Yes |
| Interrupts/diagnostics/status information / Alarms / Limit value alarm | Yes; Parameterizable, channel 0 |
| Interrupts/diagnostics/status information / Diagnoses / Diagnostic information readable | Yes |
| Interrupts/diagnostics/status information / Diagnostics indication LED / Group error SF (red) | Yes |
| Potential separation / Potential separation analog inputs / between the channels | No |
| Potential separation / Potential separation analog inputs / between the channels and backplane bus | Yes |
| Potential separation / Potential separation analog inputs / between the channels and the power supply of the | Yes; Not for 2-wire transmitters |
| Isolation / Isolation tested with | 500 V DC |
| Connection method / required front connector | 20-pin |
| Dimensions / Width | 40 mm |
| Dimensions / Height | 125 mm |
| Dimensions / Depth | 120 mm |
| Weights / Weight, approx. | 250 g |
| Product type designation | SM 331 |
| Number of poles | 20 |
Supported signals and ranges
- Supply voltage / Load voltage L+ / Rated value (DC): 24 V
- Supply voltage / Load voltage L+ / Reverse polarity protection: Yes
- Input current / from load voltage L+ (without load), max.: 30 mA
- Analog inputs / For resistance measurement: 1
- Analog inputs / permissible input voltage for voltage input (destruction limit),: 20 V; continuous; 75 V for max. 1 s (mark to space ratio 1:20)
- Analog inputs / Constant measurement current for resistance-type transmitter,: 1.67 mA
- Analog inputs / Input ranges / Voltage: Yes
- Analog inputs / Input ranges / Current: Yes
Scope of supply
We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.
Frequently asked questions
Is the same product family enough to identify a replacement?
The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.
What information is needed to check connections and accessories?
Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.
Can you assess a faulty part?
Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.
Why buy from FOXON
Replacement part availability
We will check current part availability and confirm the possible delivery date before you order.
New original and refurbished parts
We will specify the available version and condition of the particular unit in the quotation.
Parts with a warranty
We will confirm the warranty period according to the part condition and specific quotation.
Diagnostics and repairs
For a faulty unit, we will check the options for diagnostics and professional repair.
Part conditions available for sale
Part conditions and warranty
- New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
- New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
- New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
- New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
- Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
- Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
- Used (U): Functional used part. 3-month warranty.


Sales, repairs and buyback of automation parts
We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.
Need to buy or repair this part?
Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.
Request a quote for purchase or repairHighlighted items are mandatory.