6AG1134-6TD00-2CA1
- SIEMENS
- SIMATIC ET 200 / DP
- SIMATIC ET 200SP
- 6AG1134-6TD00-2CA1
6AG1134-6TD00-2CA1
SIPLUS ET 200SP AI 4xI 2-wire 4-20mA HART based on 6ES7134-6TD00-0CA1 with conformal coating, -40…+60 °C, start up -30 °C, analog HART input module, suitable for BU type A0, A1, color code CC03, channel diagnostics, 16-bit, +/-0.3% More
Code: 6AG1134-6TD00-2CA1
SIPLUS ET 200SP AI 4xI 2-wire 4-20mA HART based on 6ES7134-6TD00-0CA1 with conformal coating, -40…+60 °C, start up -30 °C, analog HART input module, suitable for BU type A0, A1, color code CC03, channel diagnostics, 16-bit, +/-0.3% More
Code: 6AG1134-6TD00-2CA1
Repair of the part
| Name | Code | Delivery | Warranty | Price excl. VAT | |
|---|---|---|---|---|---|
| Complete part repair | 6AG1134-6TD00-2CA1 O | 3-6 weeks | 24 months | On request | Enquire a repair |
6AG1134-6TD00-2CA1 – AI 4xI 2-wire HART
Siemens 6AG1134-6TD00-2CA1: SIPLUS ET 200SP AI 4xI 2-wire 4-20mA HART based on 6ES7134-6TD00-0CA1 with conformal coating, -40…+60 °C, start up -30 °C, analog HART input module, suitable for BU type A0, A1, color code CC03, channel diagnostics, 16-bit, +/-0.3%.
Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.
Technical specifications
| Manufacturer | Siemens |
|---|---|
| Order number | 6AG1134-6TD00-2CA1 |
| Product type | AI 4xI 2-wire HART |
| Firmware version / FW update possible | Yes |
| Supply voltage / Rated value (DC) | 24 V |
| Supply voltage / permissible range, lower limit (DC) | 19.2 V |
| Supply voltage / permissible range, upper limit (DC) | 28.8 V |
| Supply voltage / Reverse polarity protection | Yes |
| Input current / Current consumption, max. | 25 mA; without sensor supply |
| Encoder supply / 24 V encoder supply / Output current, max. | 20 mA; max. 50 mA per channel for a duration < 10 s |
| Power loss / Power loss, typ. | 0.65 W; without sensor supply |
| Analog inputs / Number of analog inputs | 4; Differential inputs |
| Analog inputs / permissible input current for current input (destruction limit), | 50 mA |
| Analog inputs / Input ranges (rated values), currents / 0 to 20 mA | No |
| Analog inputs / Input ranges (rated values), currents / -20 mA to +20 mA | No |
| Analog inputs / Input ranges (rated values), currents / 4 mA to 20 mA | Yes; 15 bit + sign |
| Analog inputs / Input ranges (rated values), currents / Input resistance (4 mA to 20 mA) | 280 Ω; + approx. 0.35 V diode forward voltage |
| Analog inputs / Cable length / shielded, max. | 800 m |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max. | 16 bit |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Integration time, parameterizable | Yes; channel by channel |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Interference voltage suppression for interference | 10 / 50 / 60 Hz |
| Potential separation / Potential separation channels / between the channels | No |
| Ambient temperature during operation / horizontal installation, min. | -40 °C; = Tmin (incl. condensation/frost); start-up @ -30 °C |
| Ambient temperature during operation / horizontal installation, max. | 60 °C; = Tmax; +70 °C with spacing modules (6AG1193-6BN00-7BA0) or configured slots to the left and right of the module |
| Ambient temperature during operation / vertical installation, min. | -40 °C; = Tmin (incl. condensation/frost); start-up @ -30 °C |
| Ambient temperature during operation / vertical installation, max. | 50 °C; = Tmax |
| Width | 15 mm |
| Height | 73 mm |
| Depth | 58 mm |
| Weights / Weight, approx. | 31 g |
Part variants and further information
- New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
- New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
- New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
- New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
- Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
- Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
- Used (U): Functional used part. 3-month warranty.


Buy parts and arrange repairs with FOXON
We supply new original and refurbished parts with a warranty. We confirm current availability and the possible delivery date before you place an order. For faulty parts, we check the options for diagnostics and professional repair.
Need to buy or repair this part?
Send the full order number, required quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.
Request a quote for purchase or repairHighlighted items are mandatory.