6AG1134-4GD00-2AB0

6AG1134-4GD00-2AB0


SIEMENS

SIPLUS ET 200S EM 4 AI I 2-wire based on 6ES7134-4GD00-0AB0 with conformal coating, -25ÔǪ+70 -¦C, electronic module 4-20 mA; 13 bit 15 mm width, for 2-wire transmitter cycle time 40 ms/module with SF LED (group fault) More

Code: 6AG1134-4GD00-2AB0

from 336 EUR excl. VAT (406,56 EUR Incl. VAT)
Total in stock: 2 pcs External stock 2 pcs
Variant does not exist

Rezervace termínu

Get a quote
SIEMENS

SIPLUS ET 200S EM 4 AI I 2-wire based on 6ES7134-4GD00-0AB0 with conformal coating, -25ÔǪ+70 -¦C, electronic module 4-20 mA; 13 bit 15 mm width, for 2-wire transmitter cycle time 40 ms/module with SF LED (group fault) More

Code: 6AG1134-4GD00-2AB0

Part Sales 1

Condition Code Warranty Availability Delivery
Express?
Price excl. VAT
Refurbished (R) 6AG1134-4GD00-2AB0 R 12/24 months In external stock 2 pcs
Within 2-4 days / Express
On request

Repair of the part

Name Code Delivery Warranty Price excl. VAT
Complete part repair 6AG1134-4GD00-2AB0 O 3-6 weeks 24 months On request Enquire a repair

6AG1134-4GD00-2AB0

Siemens 6AG1134-4GD00-2AB0: SIPLUS ET 200S EM 4 AI I 2-wire based on 6ES7134-4GD00-0AB0 with conformal coating, -25…+70 °C, electronic module 4-20 mA; 13 bit 15 mm width, for 2-wire transmitter cycle time 40 ms/module with SF LED (group fault).

Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.

Request a quote for purchase or repair

Technical specifications

ManufacturerSiemens
Order number6AG1134-4GD00-2AB0
Supply voltage / Load voltage L+ / Rated value (DC)24 V; From power module
Supply voltage / Load voltage L+ / Reverse polarity protectionYes
Input current / from load voltage L+ (without load), max.125 mA
Input current / from backplane bus 3.3 V DC, max.10 mA
Output voltage / Power supply to the transmitters / presentYes
Output voltage / Power supply to the transmitters / short-circuit proofYes; approx. 200 mA for module
Power loss / Power loss, typ.0.6 W
Analog inputs / Number of analog inputs4
Analog inputs / permissible input current for current input (destruction limit),30 mA; limited electronically
Analog inputs / Cycle time (all channels) max.40 ms; 33 to 40 ms
Analog inputs / Input ranges (rated values), currents / 4 mA to 20 mAYes; Into 25 Ohm
Analog inputs / Cable length / shielded, max.200 m
Analog value generation for the inputs / Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max.13 bit; 4 to 20 mA: 13 bit
Analog value generation for the inputs / Integration and conversion time/resolution per channel / Integration time, parameterizableYes
Analog value generation for the inputs / Integration and conversion time/resolution per channel / Integration time (ms)16,67 / 20 ms
Analog value generation for the inputs / Integration and conversion time/resolution per channel / Interference voltage suppression for interference50 / 60 Hz
Potential separation / Potential separation analog inputs / between the channelsNo
Potential separation / Potential separation analog inputs / between the channels and backplane busYes
Potential separation / Potential separation analog inputs / Between the channels and load voltage L+No
Ambient temperature during operation / min.-25 °C; = Tmin
Ambient temperature during operation / max.70 °C; = Tmax
Altitude during operation relating to sea level / Installation altitude above sea level, max.5 000 m
Altitude during operation relating to sea level / Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
Width15 mm
Height81 mm
Depth52 mm
Weights / Weight, approx.40 g
Part variants and further information
  • New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
  • New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
  • New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
  • New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
  • Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
  • Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
  • Used (U): Functional used part. 3-month warranty.

Buy parts and arrange repairs with FOXON

We supply new original and refurbished parts with a warranty. We confirm current availability and the possible delivery date before you place an order. For faulty parts, we check the options for diagnostics and professional repair.

More about parts sales, repairs and buyback

Need to buy or repair this part?

Send the full order number, required quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.